1、Designation: C 1489 01 (Reapproved 2008)1Standard Specification forLime Putty for Structural Purposes1This standard is issued under the fixed designation C 1489; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi

2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEA units statement was added editorially as new subsection 1.2 in September 2008.1. Scope1.1 This specification covers lime putty produ

3、cts made fromhydrated lime or quicklime products. Lime putty is suitable foruse in masonry, plaster and stucco applications.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of

4、 thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 5 Specification for Qu

5、icklime for Structural PurposesC25 Test Methods for Chemical Analysis of Limestone,Quicklime, and Hydrated LimeC50 Practice for Sampling, Sample Preparation, Packag-ing, and Marking of Lime and Limestone ProductsC51 Terminology Relating to Lime and Limestone (as usedby the Industry)C110 Test Methods

6、 for Physical Testing of Quicklime,Hydrated Lime, and LimestoneC 185 Test Method for Air Content of Hydraulic CementMortarC 206 Specification for Finishing Hydrated LimeC 207 Specification for Hydrated Lime for Masonry Pur-poses3. Terminology3.1 Definitions:3.1.1 lime puttythe product obtained by ei

7、ther slakingquicklime with water according to the direction of the manu-facturer or by mixing hydrated lime and water to the desiredconsistency.3.1.2 Unless otherwise specified, for definitions of termsused in this standard, refer to Terminology C51.4. Chemical Composition4.1 The hydrated lime or qu

8、icklime products used to makelime putty shall conform to the following chemical composi-tion requirements:Calcium and magnesium oxides (non volatile basis) 92 % min.Carbon dioxide (presoaked basis)If sample is taken at place of manufacture 5 % max.If sample is taken at other place 7 % max.4.2 Chemic

9、al composition of putty product of unknowncomposition must be determined by drying the sample in a CO2free atmosphere by a method such as Test Methods C25,Section 21, (Free Moisture in Hydrated Lime).5. Plasticity5.1 Lime putty shall have a plasticity of not less than 200Emley units when tested by t

10、he Emley method prescribed inTest Methods C110. Vicat consistency of the putty should beadjusted to a penetration of 20 6 5 mm prior to running theEmley test. If penetration results are above 25 mm, theconsistency of the putty can be increased by allowing the puttyto settle and decanting off the exc

11、ess water or by the use of asuction pad such as the one used for the water retention test inTest Methods C110. If the penetration is below 15 mm, watershould be added to the lime putty to increase the penetration.When water is added to the putty, the putty should be mixed fora minimum of 15 s prior

12、to testing the penetration.6. Residue6.1 Residue of lime putty shall not be more than 0.5 % on a30 mesh sieve on a total putty weight basis. The residue of limeputty should be determined by the method in Test MethodsC110, Section 5, using an amount of lime putty equivalent toapproximately 100 g of s

13、olids.1This specification is under the jurisdiction of ASTM Committee C07 on Limeand is the direct responsibility of Subcommittee C07.02 on Specifications andGuidelines.Current edition approved June 1, 2008. Published September 2008. Originallyapproved in 2001. Last previous edition approved in 2001

14、 as C 1489 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor

15、Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Soaking Period7.1 Lime putty made from quicklime or hydrated lime mustbe soaked for a period of time prior to use of the product. Theactual time required to ensure complete hydration of the limeputty is dependent on the reactivit

16、y of the unhydrated oxidesused to make the putty.7.1.1 Lime putty made from quicklime must be soaked fora minimum of two weeks prior to use in construction applica-tions.7.1.2 Lime putty made with Type N hydrated lime must besoaked for at least 16 h prior to use.7.1.3 Lime putty made with Type S hyd

17、rated lime requiresenough soaking to wet the lime particles (minimum of 20min.).8. Popping and Pitting8.1 Lime putty shall show no pops or pits when tested inaccordance with the method prescribed in Test Methods C110.Vicat consistency of the lime putty should be adjusted to apenetration of 20 6 5 mm

18、 prior to running the popping andpitting test. If penetration results are above 25 mm, theconsistency of the putty can be increased by allowing the puttyto settle and decanting off the excess water or by the use of asuction pad such as the one used for the water retention test inTest Methods C110. I

19、f the penetration is below 15 mm, watershould be added to the lime putty to increase the penetration.When water is added to the putty, the putty should be mixed fora minimum of 15 s prior to testing the penetration.9. Density9.1 The wet density of the lime putty shall be no less than 80lbs/ft3and no

20、t more than 90 lbs/ft3. The density of lime puttycan be measured in the 400 ml cylindrical cup described in theApparatus Section of Test Method C 185. Care should be takenwhen placing putty in the cup to minimize the entrapment ofair. The cup should be filled in three lifts, tamping after eachlift t

21、o remove entrapped air. The top surface of the putty shouldbe struck and leveled with a metal spatula prior to weighing.The calculations used for the density determination can befound in Test Methods C110, Section 16.10. Sampling and Inspection10.1 The sampling, inspection, rejection, retesting, pac

22、kag-ing, and marking shall be conducted in accordance withPractice C50.11. Test Methods11.1 Determine the properties enumerated in this specifica-tion in accordance with the following methods:11.1.1 Chemical AnalysisTest Methods C25.11.1.2 Physical AnalysisTest Methods C110.12. Keywords12.1 finish l

23、ime; lime putty; masonry; plaster; plasticity;popping and pitting; residue; stucco; unhydrated oxidesASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that det

24、ermination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved o

25、r withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel th

26、at your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).C 1489 01 (2008)12

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1