ITU-T O 61-1988 SIMPLE EQUIPMENT TO MEASURE INTERRUPTIONS ON TELEPHONE-TYPE CIRCUITS《简单的设备来衡量中断 电话型电路-规格为测量设备(第4研究组)共3页》.pdf

上传人:fatcommittee260 文档编号:800440 上传时间:2019-02-04 格式:PDF 页数:4 大小:45.46KB
下载 相关 举报
ITU-T O 61-1988 SIMPLE EQUIPMENT TO MEASURE INTERRUPTIONS ON TELEPHONE-TYPE CIRCUITS《简单的设备来衡量中断 电话型电路-规格为测量设备(第4研究组)共3页》.pdf_第1页
第1页 / 共4页
ITU-T O 61-1988 SIMPLE EQUIPMENT TO MEASURE INTERRUPTIONS ON TELEPHONE-TYPE CIRCUITS《简单的设备来衡量中断 电话型电路-规格为测量设备(第4研究组)共3页》.pdf_第2页
第2页 / 共4页
ITU-T O 61-1988 SIMPLE EQUIPMENT TO MEASURE INTERRUPTIONS ON TELEPHONE-TYPE CIRCUITS《简单的设备来衡量中断 电话型电路-规格为测量设备(第4研究组)共3页》.pdf_第3页
第3页 / 共4页
ITU-T O 61-1988 SIMPLE EQUIPMENT TO MEASURE INTERRUPTIONS ON TELEPHONE-TYPE CIRCUITS《简单的设备来衡量中断 电话型电路-规格为测量设备(第4研究组)共3页》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 / TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU30%#) amended at Geneva, 1980, and at Melbourne, 1988)The requirements for the characteristics of a simple interruption counter equipment capable of detecting shortinterruptions in transmission on audio chann

2、els are described below and must be adhered to in order to ensurecompatibility between equipments standardized by the CCITT and produced by different manufacturers.1 Definitions1.1 interruptionFor the purpose of this specification an interruption shall be regarded as a break in transmission or drop

3、in thelevel of a test tone below a designated threshold.1.2 dead timeThe dead time is defined for the purpose of this specification as the time after which the counter is ready torecord another interruption following the end of the preceding interruption.2 The detector2.1 GeneralAll interruptions ab

4、ove 3.5 ms shall be detected. Interruptions of less than 2 ms shall not be recognized norrestoration of the signal for less than 2 ms. Interruptions separated by more than 4 ms shall be detected separately.2.2 Interruption detection thresholdThe instrument shall be capable of adjustment to threshold

5、 levels of 6 and 10 dB. The accuracy of theinstrument at these threshold levels shall be 1 dB.2.3 Input conditions2.3.1 The detector shall respond to a test signal of 2000 Hz 100 Hz (see also 4).2.3.2 The instrument shall be capable of adjustment for input levels between +10 dBm and 30 dBm.2.4 Input

6、 impedance (frequency range 300 Hz to 4 kHz) balanced, earth free. Input longitudinal interference loss 46 dB2.4.1 Terminating impedance (other impedances optional) 600 ohms Return loss 30 dB2.4.2 High impedance approx. 20 kohms Bridging loss across 300 ohms . 0.15 dB.2.5 Dead time2.5.1 The dead tim

7、e of an electronic instrument shall be 3 ms 1 ms.2.5.2 The dead time of an instrument with mechanical counters shall be 125 ms 25 ms.2.5.3 A switch shall be provided on the electronic instrument giving an optional 125 ms 25 ms dead time to enablecomparable tests to be made with instruments using mec

8、hanical counters.2 Fascicle IV.4 - Rec. O.612.6 Auxiliary logic outputAn auxiliary output from the detector shall be provided wired to a suitable socket giving a logic output forcomputer access or auxiliary equipment. The output from this socket shall be a two-state digital signal:logic “0”: signal

9、level above the threshold;logic “1”: interruption, signal level below the threshold.The output levels shall be as supplied by TTL (Transistor-Transistor Logic) integrated circuits. The outputimpedance shall be less than 2000 ohms, the precise value depending on the requirements of individual Adminis

10、trations.2.7 Timing clock (optional)A timing clock shall be provided which shall limit the test duration to any period up to one hour. A manualposition shall be provided on the clock for special testing purposes when test periods of greater than one hour arerequired.3 The counter3.1 GeneralAll inter

11、ruptions of greater than 3 ms shall be recorded. The interruptions shall be recorded on a single counterwhich shall have at least a three digit display. At the end of the testing period the counter display shall hold itsaccumulated total.3.2 Power failureIn the event of a power failure the counter s

12、hall hold its accumulated total and resume the count when thepower supply is restored. Should it prove impossible to meet this requirement a visual indication shall be provided toshow that a power failure has taken place.4 Simultaneous measurementsThe measurement of interruptions may be provided in

13、an instrument which also makes measurements of othertransient impairments, e.g., amplitude and phase hits. A test signal frequency of 1020 Hz 10 Hz may be used tofacilitate the integration of several measurements of transient phenomena in such a combined instrument. In all otherrespects, the measurement of interruptions shall be in accordance with the principles of this Recommendation.5 Operating environmentThe electrical performance requirements shall be met when operating at the climatic conditions as specified inRecommendation O.3, 2.1.

展开阅读全文
相关资源
猜你喜欢
  • DIN 58932-3-2017 Haematology - Determination of the concentration of blood corpuscles in blood - Part 3 Reference method for the determination of the concentration of erythrozytes .pdf DIN 58932-3-2017 Haematology - Determination of the concentration of blood corpuscles in blood - Part 3 Reference method for the determination of the concentration of erythrozytes .pdf
  • DIN 58932-4-2003 Haematology - Determination of the concentration of blood corpuscles in blood - Part 4 Reference procedure for the determination of the concentration of leucocytes.pdf DIN 58932-4-2003 Haematology - Determination of the concentration of blood corpuscles in blood - Part 4 Reference procedure for the determination of the concentration of leucocytes.pdf
  • DIN 58932-5-2007 Haematology - Determination of the concentration of blood corpuscles in blood - Part 5 Reference method for the determination of the concentration of thrombocytes .pdf DIN 58932-5-2007 Haematology - Determination of the concentration of blood corpuscles in blood - Part 5 Reference method for the determination of the concentration of thrombocytes .pdf
  • DIN 58933-1-1995 Haematology - Procedure for determining the volume fraction of erythrocytes (packed cell volume) in blood - Part 1 Reference method based on centrifugation《血液学 血液中.pdf DIN 58933-1-1995 Haematology - Procedure for determining the volume fraction of erythrocytes (packed cell volume) in blood - Part 1 Reference method based on centrifugation《血液学 血液中.pdf
  • DIN 58934-1-1997 Haematology - Control material for the CBC - Part 1 Control bloods《血液学 血象监控材料 第1部分 监控血液》.pdf DIN 58934-1-1997 Haematology - Control material for the CBC - Part 1 Control bloods《血液学 血象监控材料 第1部分 监控血液》.pdf
  • DIN 58935-1-1997 Haematologie - Determination of the erythrocyte sedimentation rate in blood - Part 1 Selected method《血液学 血液中红细胞沉降测定 第1部分 选定的方法》.pdf DIN 58935-1-1997 Haematologie - Determination of the erythrocyte sedimentation rate in blood - Part 1 Selected method《血液学 血液中红细胞沉降测定 第1部分 选定的方法》.pdf
  • DIN 58936-1-2000 Quality management in laboratory medicine - Part 1 Basic terminology《实验室医学的质量管理 第1部分 基础术语》.pdf DIN 58936-1-2000 Quality management in laboratory medicine - Part 1 Basic terminology《实验室医学的质量管理 第1部分 基础术语》.pdf
  • DIN 58936-2-2001 Quality management in laboratory medicine - Part 2 Terminology for quality and application of test procedure《实验室医学质量保证 第2部分 试验过程质量和应用术语》.pdf DIN 58936-2-2001 Quality management in laboratory medicine - Part 2 Terminology for quality and application of test procedure《实验室医学质量保证 第2部分 试验过程质量和应用术语》.pdf
  • DIN 58939-1-2000 Haemostaseology - Reference plasma - Part 1 Requirements preparation《止血学 基准血浆 第1部分 要求和制备》.pdf DIN 58939-1-2000 Haemostaseology - Reference plasma - Part 1 Requirements preparation《止血学 基准血浆 第1部分 要求和制备》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1