1、Lessons Learned Entry: 1246Lesson Info:a71 Lesson Number: 1246a71 Lesson Date: 2002-06-17a71 Submitting Organization: HQa71 Submitted by: David LengyelSubject: International Space Station/Damage Control/Fire and Depressurization Hazards Description of Driving Event: Improvements needed to locate fir
2、es and leaks, as well as improvements needed in procedures and tools to control these hazards.Lesson(s) Learned: While the basic framework for system engineering of damage detection, assessment, and control has been established, work remains to be accomplished to reduce vulnerability to the hazards
3、of fire and pressure leaks.Recommendation(s): Examine procedures, tools and instrumentation to locate fires and penetrations more rapidly, especially those occurring behind equipment racks. Improve the ability of the crew to communicate with each other while dealing with emergencies. Create, qualify
4、, and stock kits for rapid short- and long-term repair of penetrations. Develop a procedure to be used in the event of combined depressurization and fire. Evidence of Recurrence Control Effectiveness: A prototype, hand held, Ultra Sonic leak detector has been deployed to ISS for evaluation. This det
5、ector allows more rapid identification of leaks in pressurized elements. It has been utilized on-orbit to locate minor leaks in components. A wireless intercom headset has been proposed. Implementation of this capability will be evaluated as part of the Pre-Planned Program Improvement (P3I) Process.
6、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-The three-phased development plan of joint U.S. and Russian Leak Detection and Repair Team includes both short-term and long-term repair of penetrations. NASA will evaluate the adequacy of current fire
7、 and depressurization procedures to handle a combined fire and depressurization event. Documents Related to Lesson: N/AMission Directorate(s): a71 Space Operationsa71 Exploration SystemsAdditional Key Phrase(s): a71 Aerospace Safety Advisory Panela71 Emergency Preparednessa71 Fire Protectiona71 Huma
8、n Factorsa71 Personal Protective Equipmenta71 Risk Management/Assessmenta71 Safety & Mission Assurancea71 SpacecraftAdditional Info: Approval Info: a71 Approval Date: 2002-06-27a71 Approval Name: Bill Loewya71 Approval Organization: HQa71 Approval Phone Number: 202-358-0528Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1