1、AEROSPACE MATERIAL SPECIFICATION AMS4087 REV. H Issued 1945-11 Revised 2006-09 Reaffirmed 2015-05 Superseding AMS4087G Aluminum Alloy Tubing, Seamless, Drawn (2024-0) Reinstate Composition Annealed (Composition similar to UNS A92024) RATIONALE AMS4087H has been reaffirmed to comply with the SAE five
2、-year review policy. _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infri
3、ngement arising therefrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2015 SAE International All rights reserv
4、ed. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada
5、) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AMS4087H 1. SCOPE 1.1 Form This specification covers an alum
6、inum alloy in the form of seamless, drawn tubing. 1.2 Application These parts have been used typically for parts requiring a high-strength, non-weldable alloy. Parts are usually solution heat treated and aged before use, but usage is not limited to such applications. 2. APPLICABLE DOCUMENTS The issu
7、e of the following documents in effect on the date of the purchase order forms a part of this specification to the extent specified herein. The supplier may work to a subsequent revision of a document unless a specific document issue is specified. When the referenced document has been cancelled and
8、no superseding document has been specified, the last published issue of that document shall apply. 2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. AMS 2355
9、Quality Assurance Sampling and Testing, Aluminum Alloys and Magnesium Alloys, Wrought Products, Except Forging Stock, and Rolled, Forged or Flash Welded Rings AMS 2772 Heat Treatment of Aluminum Alloy Raw Materials AS 4330 Standard Dimensions for, Design Standard Tubing, Flared AS 33583 Standard Dim
10、ensions for Tubing End Double Flare 2.2 ASTM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org. ASTM B 660 Packaging/Packing of Aluminum and Magnesium Product ASTM B 666/B 666M Identification Markin
11、g of Aluminum Products 2.3 ANSI Publications Available from American National Standards Institute, 25 West 43rd Street, New York, NY 10036, Tel: 212-642-4900, www.ansi.org. ANSI H35.2 Dimensional Tolerances for Aluminum Mill Products ANSI H35.2M Dimensional Tolerances for Aluminum Mill Products (Met
12、ric) 3. TECHNICAL REQUIREMENTS 3.1 Composition Shall conform to the percentages by weight shown in Table 1, determined in accordance with AMS 2355: TABLE 1 - COMPOSITION Element min maxSilicon Iron Copper Manganese Magnesium Chromium Zinc Titanium Other Elements, each Other Elements, total Aluminum
13、- - 3.8 0.30 1.2 - - - - - remainder0.50 0.50 4.9 0.9 1.8 0.100.250.150.050.153.2 Condition Annealed. 3.3 Properties Tubing shall conform to the following requirements, determined in accordance with AMS 2355 on the mill produced size. 3.3.1 As Annealed 3.3.1.1 Tensile Properties Shall be as shown in
14、 Table 2 for tubing having nominal wall thickness of 0.18 to 0.500 inch (0.46 to 12.70 mm) inclusive. TABLE 2 - AS ANNEALED, MAXIMUM TENSILE PROPERTIES Property Value Tensile Strength Yield Strength at 0.2% Offset 32.0 ksi (221 MPa) 15.0 ksi (103 MPa) SAE INTERNATIONAL AMS4087H Page 2 of 6_ 3.3.1.2
15、Flattening Tubing having nominal wall thickness less than 10% of the nominal OD shall withstand, without cracking, flattening sideways under a load applied gradually at room temperature until the outside dimension under load is equal to the flattening factor shown in Table 3 times the nominal wall t
16、hickness. TABLE 3 - FLATTENING FACTOR Nominal Wall Thickness Inch Nominal Wall Thickness Millimeters Factor Up to 0.049, incl Up to 1.24, incl 3 Over 0.049 Over 1.24 4 3.3.1.2.1 Retesting Procedure If tubing does not pass the flattening test of 3.3.1.2, a section of tube not less than 1/2 inch (12.7
17、 mm) in length and including one-third to one-half the circumference of the tube shall withstand, without cracking, bending at room temperature through an angle of 180 degrees around a diameter equal to the bend factor shown in Table 4 times the nominal wall thickness of the tubing with axis of bend
18、 parallel to axis of tube and with inside of tube on inside of bend. TABLE 4 - BENDING FACTOR Nominal Wall Thickness Inch Nominal Wall Thickness Millimeters Factor Up to 0.049, incl Up to 1.24, incl 1 Over 0.049 Over 1.24 2 3.3.1.3 Flarability Tubing of 0.375 inch (9.52 mm) and under in nominal OD s
19、hall withstand double-flaring and tubing over 0.375 inch (9.52 mm) in nominal OD shall withstand single-flaring without formation of cracks or other visible defects by being forced axially, at room temperature, with steady pressure over a hardened and polished tapered steel pin having a 74-degree in
20、cluded angle to produce a flare having a permanent expanded OD not less than specified in Table 5. (See 8.2.1.) TABLE 5A - FLARABILITY, INCH/POUND UNITS Nominal OD Inch Expanded ODInch Nominal ODInches Expanded OD Inches 0.125 0.200 0.750 0.937 0.188 0.302 1.000 1.187 0.250 0.359 1.250 1.500 0.312 0
21、.421 1.500 1.721 0.375 0.484 1.750 2.106 0.500 0.656 2.000 2.356 0.625 0.781 2.500 2.856 3.000 3.356 TABLE 5B - FLARABILITY, SI UNITS Nominal OD Millimeters Expanded ODMillimeters Nominal ODMillimeters Expanded OD Millimeters 3.18 5.08 19.05 23.80 4.78 7.67 25.40 30.15 6.35 9.12 31.75 38.10 7.92 10.
22、69 38.10 43.71 9.52 12.29 44.45 53.49 12.70 16.66 50.80 59.84 15.88 19.84 63.50 72.54 76.20 85.24 SAE INTERNATIONAL AMS4087H Page 3 of 6_ 3.3.1.3.1 Tubing with nominal OD between any two standard sizes shown in 3.3.1.3 shall take the same percentage flare as shown for the larger of the two sizes. 3.
23、3.2 After Solution Heat Treatment and Aging Tubing as received by purchaser, after solution heat treatment in accordance with AMS 2772 and aging for not less than 4 days at room temperature to the T42 Temper, shall have the following properties: 3.3.2.1 Tensile Properties Shall be as specified in Ta
24、ble 6. TABLE 6A - MINIMUM TENSILE PROPERTIES, INCH/POUND UNITS Nominal Wall Thickness Inch Tensile Strength ksi Yield Strengthat 0.2% Offsetksi Elongation in 2 Inches or 4D % Cut Out Specimen Elongation in 2 Inches or 4D % Full Section Specimen 0.018 to 0.024, incl 64.0 40.0 - 10 Over 0.024 to 0.049
25、, incl 64.0 40.0 10 12 Over 0.049 to 0.259, incl 64.0 40.0 10 14 Over 0.259 to 0.500, incl 64.0 40.0 12 16 TABLE 6B - MINIMUM TENSILE PROPERTIES, SI UNITS Nominal Wall Thickness Millimeters Tensile Strength MPa Yield Strengthat 0.2% OffsetMPa Elongation in 50.8 mm or 4D % Cut Out Specimen Elongation
26、 in 50.8 mm or 4D % Full Section Specimen 0.46 to 0.61, incl 441 276 - 10 Over 0.61 to 1.24, incl 441 276 10 12 Over 1.24 to 6.58, incl 441 276 10 14 Over 6.58 to 12.70, incl 441 276 12 16 3.4 Quality Tubing, as received by purchaser, shall be uniform in quality and condition, sound, and free from f
27、oreign materials and from imperfections detrimental to usage of the tubing. 3.4.1 Detrimental imperfections include, but are not limited to, cracks, splits, seams, inclusions, or severe crosshatching (surface breaks) that cannot be removed by lightly hand-sanding, using 180 grit or finer sandpaper.
28、3.5 Tolerances Shall conform to all applicable requirements of ANSI H35.2 or ANSI H35.2M. 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for Inspection The vendor of tubing shall supply all samples for vendors tests and shall be responsible for the performance of all required tests. Purchaser re
29、serves the right to sample and to perform any confirmatory testing deemed necessary to ensure that the tubing conforms to specified requirements. 4.2 Classification of Tests 4.2.1 Acceptance Tests Composition (3.1), tensile properties as annealed (3.3.1.1) and after solution heat treatment and aging
30、 (3.3.2), quality (3.4), and tolerances (3.5) are acceptance tests and, except for composition, shall be performed on each lot of tubing. SAE INTERNATIONAL AMS4087H Page 4 of 6_ 4.2.2 Periodic Tests Tests for flattening (3.3.1.2) and flarability (3.3.1.3) are periodic tests and shall be performed at
31、 a frequency selected by the vendor unless frequency of testing is specified by purchaser. 4.3 Sampling and Testing Shall be in accordance with AMS 2355 and the following: 4.3.1 Specimens for flarability test (3.3.1.3) shall be full tubes or sections cut from a tube. The end of the specimen to be fl
32、ared shall be cut square, with the cut end smooth and free from burrs, but, except for sizes 0.375 inch (9.52 mm) and under in nominal diameter, not rounded. 4.4 Reports The vendor of tubing shall furnish with each shipment a report stating that the tubing conforms to the composition and tolerances
33、(and NDT inspection, when required); and showing the numerical results of tests on each inspection lot to determine conformance to the other acceptance test requirements and periodic test requirements when performed. This report shall include the purchase order number, inspection lot number(s), AMS
34、4087H, size, and quantity. The report shall also identify the producer, the product form, and the size of the mill product. 4.5 Resampling and Retesting Shall be in accordance with AMS 2355. 5. PREPARATION FOR DELIVERY 5.1 Identification Shall be in accordance with ASTM B 666/B 666M. 5.2 Packaging 5
35、.2.1 Tubing shall be oiled, prior to shipment, with a light corrosion-inhibiting oil. 5.2.2 Tubing shall be prepared for shipment in accordance with ASTM B 660, and in compliance with applicable rules and regulations pertaining to the handling, packaging, and transportation of the tubing to ensure c
36、arrier acceptance and safe delivery. 6. ACKNOWLEDGMENT A vendor shall mention this specification number and its revision letter in all quotations and when acknowledging purchase orders. 7. REJECTIONS Tubing not conforming to this specification, or to modifications authorized by purchaser, will be su
37、bject to rejection. 8. NOTES 8.1 A change bar (l) located in the left margin is for the convenience of the user in locating areas where technical revisions, not editorial changes, have been made to the previous issue of this specification. An (R) symbol to the left of the document title indicates a
38、complete revision of the specification, including technical revisions. Change bars and (R) are not used in original publications, nor in specifications that contain editorial changes only. SAE INTERNATIONAL AMS4087H Page 5 of 6_ 8.2 Terms used in AMS are clarified in ARP1917 and as follows: 8.2.1 A
39、double flare is similar to a standard single flare except that the flare is folded back on itself such that the cut edge is inside the flare near the ID of the tube. Definitions and illustrations of single flaring are shown in AS 4330; double flaring is defined and illustrated in AS33583. 8.3 Dimens
40、ions and properties in inch/pound units and the Fahrenheit temperatures are primary; dimensions and properties in SI units and the Celsius temperatures are shown as the approximate equivalents of the primary units and are presented only for information. 8.4 Purchase documents should specify not less
41、 than the following: AMS 4087H Size of tubing desired Quantity of tubing desired. 8.5 Similar Specifications Federal WW-T-700/3, Temper 0, is listed for information only and shall not be construed as an acceptable alternate unless all requirements of this AMS are met. PREPARED BY AMS COMMITTEE “D” SAE INTERNATIONAL AMS4087H Page 6 of 6_