1、 AEROSPACE STANDARD WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/ POLYMIDE INSULATED, NORMAL WEIGHT, SILVER COATED, COPPER CONDUCTOR, 200 C, 600 VOLT, ROHS AS22759/86Copyright 2017 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or tran
2、smitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SA
3、E WEB ADDRESS: http:/www.sae.org ISSUED2000-06REAFFIRMED 2006-04REVISED2017-09THIRD ANGLE PROJECTION CUSTODIAN: AE-8/AE-8D REV.D FEDERAL SUPPLY CLASS 6145 AS22759/86 SHEET 1 OF 6 REV. D PROCUREMENT SPECIFICATION: AS22759 SAE Technical Standards Board Rules provide that: “This report is published by
4、SAEtoadvance thestate of technicaland engineering sciences. The useof this report is entirely voluntary, and its applicability andsuitability for any particularuse, includingany patent infringement arisingtherefrom,is thesole responsibility of theuser.” SAE reviews eachtechnical reportatleast every
5、fiveyears at whichtime it may be revised, reaffirmed, stabilized, or cancelled. SAE invitesyour written comments and suggestions.SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AS22759/86D RATIONALE SPECIFICATION UPDATED TO INCLUDE AS29606 CO
6、NDUCTOR REQUIREMENTS, ROHS RESTRICTIONS, AND AS22759 MODIFICATIONS. THIS CHANGE ALSO INCREASES THE MAXIMUM WEIGHT REQUIREMENTS FOR WIRE SIZES 8 THROUGH 02 TO ACCOUNT FOR INCREASED CIRCULAR MIL AREA (CMA) ADOPTED IN AS29606. AS22759 IS A CONVERTED MILITARY SPECIFICATION ORIGINALLY NOTED AS MIL-W-2275
7、9 CREATED IN 1971. CONDUCTOR REQUIREMENTS WERE ORIGINALLY DEFINED BY ASTM B3, B298, AND B355 FOR TIN, SILVER, AND NICKEL PLATE RESPECTIVELY. THESE SPECIFICATIONS CONTROLLED THE CONDUCTOR BY ESTABLISHING STRAND SIZE, CONDUCTOR SIZE, AND MAXIMUM DCR (DIRECT CURRENT RESISTANCE). BY THE LATE 1980S, COND
8、UCTOR PRODUCERS WERE PRODUCING TIGHT TOLERANCE CONDUCTORS WHICH WERE MADE AT THE MINIMUM DIMENSIONAL AND MAXIMUM DCR LIMITS OF THE SPECIFICATION TO REDUCE THE WEIGHT (MASS) OF THE FINALLY INSULATED WIRE. BY THE EARLY 1990S, THE TIGHT TOLERANCE CONDUCTORS WERE PREVALENT THROUGHOUT AEROSPACE. ABOUT TH
9、E SAME TIME, LARGE GAUGE SIZE CONDUCTORS (SIZE 8 THROUGH 4/0) STARTED EXHIBITING CRIMP FAILURES IN TERMINAL LUGS MOUNTED ON AIRCRAFT GENERATORS. SINCE THESE CIRCUITS ROUTED PRIMARY ELECTRICAL POWER FROM THE GENERATOR TO THE MAIN POWER DISTRIBUTION CENTERS, CRIMP DEGRADATION RESULTING IN DISRUPTION O
10、F ELECTRICAL POWER CAUSED SIGNIFICANT CONCERN. SEVERAL OEMS AS WELL AS NAVY AND AIR FORCE LABORATORIES INVESTIGATED THE FAILURES AND DETERMINED THAT THE FAILED CRIMPS WERE DUE TO A COMBINATION OF LOW CMA, HIGH VIBRATION, AND THERMAL CYCLING. ADDITIONAL TESTING ESTABLISHED MINIMUM CMA LEVELS WHICH WO
11、ULD PREVENT THE CRIMP FAILURES. THESE NEW LIMITS WERE OFFERED TO ASTM BUT REJECTED. NAVAIR THEN PRODUCED AN ENGINEERING POSITION LETTER (EPL) TO MANDATE THE INCREASED CMAS ON STRANDING USED IN AS22759 CONSTRUCTIONS. NAVAIR THEN CREATED MIL-W-29606, WHICH WAS INTENDED TO REPLACE THE ASTM SPECIFICATIO
12、NS AS THE REQUIRED CONDUCTOR SPECIFICATION. BEFORE THE MIL-W-29606 COULD BE ADDED TO MIL-W-22759, THE SPECIFICATION TRANSITION AND ADOPTION TOOK PLACE CONVERTING THE DOCUMENTS FROM MILITARY SPECIFICATIONS TO AS DOCUMENTS IN THE 1999 TO 2000 TIME FRAME. SINCE THE EPL NO LONGER HAD LEGAL STANDING AFTE
13、R THE CONVERSION, WIRE PRODUCERS DID NOT HAVE TO ABIDE BY THE RESTRICTIONS, WHICH ALLOWED THIS ISSUE TO CREEP BACK INTO THE PRODUCTS FROM TIME TO TIME. IN 2011, THE SAE AE-8D COMMITTEE OPENED A PROJECT TO UPDATE THE AS22759 AND ITS ASSOCIATED DETAILED SPECIFICATION SHEETS. WHEN LOOKING AT THIS ISSUE
14、, THE COMMITTEE DECIDED TO ADOPT MIL-W-29606 (NOW AS29606) AND REPLACE THE ASTM REQUIREMENTS WITH THE AS29606 REQUIREMENTS. SINCE THE DIAMETER RANGE OF THE CONDUCTOR STRANDS NEEDED TO SHIFT SLIGHTLY TO THE RIGHT TO MEET THE NEW MINIMUM CMA REQUIREMENTS, OVERALL PRODUCT WEIGHT MAXIMUMS SHIFTED ABOUT
15、3 TO 5%. THE COMMITTEE EVALUATED SEVERAL METHODS OF INCORPORATING THIS CHANGE, INCLUDING CANCELING AND SUPERSESSION, BUT THE END USERS DID NOT WANT TO CHANGE PART NUMBERS FOR PRODUCTS WHICH HAVE BEEN USED IN AEROSPACE AND INDUSTRY FOR OVER 40 YEARS AND IS CURRENTLY ON THOUSANDS OF DRAWINGS. SINCE TH
16、ESE PRODUCTS ARE PRIMARILY USED FOR PRIMARY POWER DISTRIBUTION FROM THE GENERATORS TO THE MAIN DISTRIBUTION PANELS, THE WEIGHT INCREASE TO THE ELECTRICAL INTERCONNECT SYSTEM IS CONSIDERED INSIGNIFICANT. SINCE THIS CHANGE DOES AFFECT THE MAXIMUM WEIGHT LIMITS FOR SIZES 8 THROUGH 4/0, END USERS SHOULD
17、 VERIFY THAT THE NEW WEIGHT RANGES MEET THE DESIGN REQUIREMENTS OF LEGACY APPLICATIONS. CORRECTED STATE OF SINTER REQUIREMENT. NOTICE THE COMPLETE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS22759. THIS SPECIFICATION IS NOT INTENDE
18、D FOR USE IN NAVAL AIRCRAFT OR NAVAL AIR SYSTEMS APPLICATIONS. AEROSPACE STANDARD AS22759/86 SHEET 2 OF 6 REV. D WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/ POLYMIDE INSULATED, NORMAL WEIGHT, SILVER COATED, COPPER CONDUCTOR, 200 C, 600 VOLT, ROHS FP / POLYIMIDE / FP TAPE FP TAPE SIZE 26 THROUGH 10 FP
19、 / POLYIMIDE / FP TAPE FP TAPE FP TAPE SIZE 8 THROUGH 6 FP / POLYIMIDE / FP TAPE FP TAPE FP TAPE FP TAPE SIZE 4 THROUGH 04 FP FLUOROCARBON POLYMER MODIFIED POLYTETRAFLUOROETHYLENE (PTFE) CONDUCTOR STRANDED SILVER COATED COPPER FIGURE 1 - AS22759/86 CONFIGURATION AEROSPACE STANDARD AS22759/86 SHEET 3
20、 OF 6 REV. D WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/ POLYMIDE INSULATED, NORMAL WEIGHT, SILVER COATED, COPPER CONDUCTOR, 200 C, 600 VOLT, ROHS TABLE 1 - CONSTRUCTION DETAILS FOR FINISHED WIRE PART NO. 1/ WIRE SIZE CONDUCTOR 3/ FINISHED WIRE STRANDING (NUMBER OF STRANDS X SIZE GAUGE OF STRANDS) DI
21、AMETER (INCH) RESISTANCE AT 20 C (68 F) (OHMS/1000 FEET MAX) DIAMETER (INCH) WEIGHT (LB/1000 FEET) 2/ MIN MAX MIN MAX MIN TARGET MAX M22759/86-26-* M22759/86-24-* M22759/86-22-* M22759/86-20-* M22759/86-18-* M22759/86-16-* M22759/86-14-* M22759/86-12-* M22759/86-10-* M22759/86-8-* M22759/86-6-* M227
22、59/86-4-* M22759/86-2-* M22759/86-1-* M22759/86-01-* M22759/86-02-* M22759/86-03-* M22759/86-04-* 26 24 22 20 18 16 14 12 10 8 6 4 2 1 0 00 000 0000 19 X 38 19 X 36 19 X 34 19 X 32 19 X 30 19 X 29 19 X 27 37 X 28 37 X 26 133 X 29 133 X 27 133 X 25 665 X 30 817 X 30 1045 X 30 1330 X 30 1665 X 30 2109
23、 X 30 .0175 .0225 .0285 .0365 .0455 .0515 .0645 .0835 .106 .158 .198 .250 .320 .360 .395 .440 .500 .565 .0194 .0244 .0304 .0384 .0484 .0544 .0684 .0874 .110 .166 .208 .263 .340 .380 .425 .475 .540 .605 38.4 24.3 15.1 9.19 5.79 4.52 2.88 1.90 1.19 .658 .418 .264 .170 .139 .108 .085 .068 .054 .033 .03
24、8 .043 .051 .061 .068 .081 .100 .122 .180 .219 .276 .344 .388 .420 .475 .530 .590 .037 .042 .047 .055 .065 .073 .086 .105 .127 .188 .229 .288 .364 .408 .450 .505 .560 .630 1.29 1.87 2.70 4.25 6.40 8.20 12.4 18.9 29.3 55.9 86.9 141 217 265 335 419 528 676 1.42 2.04 2.90 4.48 6.65 8.50 12.9 19.7 30.8
25、57.8 89.4 145 225 274 349 438 548 698 1.55 2.20 3.10 4.70 6.90 8.80 13.4 20.4 31.6 59.7 91.9 149 233 283 363 457 568 720 1/ PART NUMBER: THE ASTERISKS IN THE PART NUMBER COLUMN OF TABLE 1 SHALL BE REPLACED BY COLOR CODE DESIGNATORS IN ACCORDANCE WITH MIL-STD-681. EXAMPLES: M22759/86-20-93 IS A 20 AW
26、G WHITE WITH ORANGE STRIPE. 2/ THE ACCEPTABLE VALUE FOR THE CPK FOR THE FINISHED WIRE WEIGHT LISTED SHALL BE 1.3, USING A NORMAL (GAUSSIAN) DISTRIBUTION TO OBTAIN THOSE CPK VALUES. 3/ CONDUCTOR SHALL CONFORM TO AS29606 TYPE SCC SMALL DIAMETER SILVER COATED COPPER CONDUCTOR FOR WIRE SIZES 26 THROUGH
27、4 AND GENERAL PURPOSE FOR WIRE SIZES 2 THROUGH 0000. REQUIREMENT: ALL REQUIREMENTS SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS22759. 1. WIRE CONSTRUCTION: WIRE CONSTRUCTION SHALL BE IN ACCORDANCE WITH FIGURE 1 AND TABLES 1, 2, 3, AND 4. TABLE 2 - WIRE INSULATION MATERIALS TAPE CODE THI
28、CKNESS (NOM) MATERIAL 1 .0020 .0005 (FP)/.0010 (POLYIMIDE)/.0005 (FP) 2 .0010 FP (SKIVED) 3 .0020 FP (SKIVED) 4 .0020 FP (UNSINTERED) 5 .0025 FP (UNSINTERED) 6 .0030 FP (UNSINTERED) AEROSPACE STANDARD AS22759/86 SHEET 4 OF 6 REV. D WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/ POLYMIDE INSULATED, NORMA
29、L WEIGHT, SILVER COATED, COPPER CONDUCTOR, 200 C, 600 VOLT, ROHS TABLE 3 - TAPE OVERLAP REQUIREMENTS 1/ WIRE SIZE WRAP 1 WRAP 2 WRAP 3 WRAP 4 NOMINAL WALL THICKNESS (MILS) TAPE CODE PERCENT OVERLAP TAPE CODE PERCENT OVERLAP TAPE CODE PERCENT OVERLAP TAPE CODE PERCENT OVERLAP MIN MAX MIN MAX MIN MAX
30、MIN MAX 26 1 50.5 54.0 4 50.5 54.0 7.4 24 1 50.5 54.0 4 50.5 54.0 7.4 22 1 50.5 54.0 4 50.5 54.0 7.4 20 1 50.5 54.0 4 50.5 54.0 7.4 18 1 50.5 54.0 4 50.5 54.0 7.4 16 1 50.5 54.0 5 50.5 54.0 8.3 14 1 50.5 54.0 5 50.5 54.0 8.3 12 1 50.5 54.0 6 50.5 54.0 9.1 10 1 50.5 54.0 6 50.5 54.0 9.1 8 2 20.5 35.0
31、 1 50.5 55.0 6 67.0 71.0 13.2 6 2 20.5 35.0 1 50.5 55.0 6 67.0 71.0 13.2 4 3 20.5 35.0 1 50.5 55.0 6 50.5 54.0 6 50.5 54.0 16.2 2 3 20.5 35.0 1 50.5 55.0 6 50.5 54.0 6 50.5 54.0 16.2 1 3 20.5 35.0 1 50.5 55.0 6 50.5 54.0 6 50.5 54.0 16.2 1/0 3 20.5 35.0 1 50.5 55.0 6 50.5 54.0 6 50.5 54.0 16.2 2/0 3
32、 20.5 35.0 1 50.5 55.0 6 50.5 54.0 6 50.5 54.0 16.2 3/0 3 20.5 35.0 1 50.5 55.0 6 50.5 54.0 6 50.5 54.0 16.2 4/0 3 20.5 35.0 1 50.5 55.0 6 50.5 54.0 6 50.5 54.0 16.2 1/ WRAP 1 IS INNERMOST TAPE WHICH IS IN CONTACT WITH THE CONDUCTOR. WRAPS 2, 3, AND 4 ARE PROGRESSIVELY FURTHER AWAY FROM THE CONDUCTO
33、R CORE. 2. WIRE PERFORMANCE RATING: TEMPERATURE RATING: 200 C (392 F) MAXIMUM CONDUCTOR CONTINUOUS TEMPERATURE. VOLTAGE RATING: 600 VOLTS (RMS) AT SEA LEVEL. THIS INSULATION SYSTEM HAS BEEN USED IN AEROSPACE APPLICATIONS USING 115 VOLTS (PHASE TO NEUTRAL), 400 HERTZ AC AND 28 VOLTS DC. VERIFICATION
34、OF THE SUITABILITY OF THIS PRODUCT FOR USE IN OTHER ELECTRICAL SYSTEM CONFIGURATIONS IS THE RESPONSIBILITY OF THE USER. 3. MATERIALS AND PHYSICAL PROPERTIES: SEE AS22759 FOR MATERIAL REQUIREMENT. MATERIALS USED IN THE MANUFACTURE OF THESE PRODUCTS SHALL COMPLY WITH THE RESTRICTION OF HAZARDOUS SUBST
35、ANCES DIRECTIVE 2002/95/EC. 4. FINISH WIRE INSULATION PROPERTIES: FINISH WIRE INSULATION PROPERTIES SHALL BE IN ACCORDANCE WITH TABLE 4. AEROSPACE STANDARD AS22759/86 SHEET 5 OF 6 REV. D WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/ POLYMIDE INSULATED, NORMAL WEIGHT, SILVER COATED, COPPER CONDUCTOR, 20
36、0 C, 600 VOLT, ROHS TABLE 4 - FINISHED WIRE INSULATION PROPERTIES REQUIREMENTS INSULATION PROPERTIES IMPULSE TEST VOLTAGE 8.0 KILOVOLTS (PEAK) HIGH FREQUENCY TEST VOLTAGE 5.7 KILOVOLTS (RMS) INSULATION STATE OF SINTER 3.0 JOULES PER GRAM MAXIMUM WIRE SIZES 26 - 10 NOT REQUIRED FOR WIRE SIZES 8 AND L
37、ARGER TAPE OVERLAP TABLE 3 LAMINATION SEALING 260 C 2 C (500 F 3.6 F), 6 HOURS INSULATION BLOCKING 200 C 2 C (392 F 3.6 F) SHRINKAGE 230 C 2 C (446 F 3.6 F) MAXIMUM CHANGE .091 INCHES WIRE SIZES 26 - 10 MAXIMUM CHANGE .125 INCHES WIRE SIZE 8 - 0000 ELECTRICAL RESISTANCE (IR) 5000 MEGOHMS (MIN)-1000
38、FEET WIRE SIZES 26 - 10 3000 MEGOHMS (MIN)-1000 FEET WIRE SIZES 8 - 0000 WET DIELECTRIC VOLTAGE 2500 VOLTS (RMS), 60 HERTZ INSULATION STRIP FORCE .25 - 6.0 POUNDS: WIRE SIZES 26 - 20 .50 - 7.0 POUNDS: WIRE SIZES 18 - 14 UV LASER MARKING 55% MINIMUM AVERAGE CONTINUOUS LENGTH SCHEDULE B 5. FINISH WIRE
39、 IDENTIFICATION: WIRE IDENTIFICATION EXCEPTIONS: NONE WIRE IDENTIFICATION DURABILITY: 125 CYCLES (250 STROKES) WITH 250 GRAMS WEIGHT STRIPE AND BAND DURABILITY: 125 CYCLES (250 STROKES) WITH 250 GRAMS WEIGHT 6. FINISH WIRE PERFORMANCE: FINISH WIRE FIXTURES APPLICABLE TO EACH WIRE SIZE SHALL BE IN AC
40、CORDANCE WITH TABLE 5. TABLE 5 - TEST MANDREL AND TEST LOAD REQUIREMENTS WIRE SIZE (AWG) TEST MANDREL DIAMETER 1/ (INCHES) TEST LOAD 1/ (LB) COLD BEND LIFE CYCLE/ BEND TEST WRAP COLD BEND LIFE CYCLE/ BEND TEST 26 24 22 20 18 16 14 12 10 8 6 4 2 1 0 00 000 0000 1.00 1.00 1.00 1.00 1.50 1.50 2.00 2.00
41、 3.00 4.00 5.00 6.00 8.00 10.00 10.00 12.00 18.00 18.00 .375 .500 .500 .500 .750 1.00 1.00 1.50 2.00 3.00 4.00 5.00 6.00 8.00 8.00 10.00 10.00 10.00 .125 .125 .125 .125 .250 .250 .375 .375 .375 .750 1.00 1.25 2.00 2.50 3.00 4.00 5.00 6.00 3.00 3.00 4.00 4.00 5.00 5.00 5.00 5.00 6.00 10.00 10.00 15.0
42、0 15.00 15.00 15.00 20.00 30.00 30.00 .50 .75 1.00 1.50 2.00 2.00 3.00 3.00 3.00 4.00 4.00 4.50 6.00 6.00 6.00 8.00 10.00 10.00 1/ TOLERANCE SHALL BE 3% OF THE GIVEN VALUES. AEROSPACE STANDARD AS22759/86 SHEET 6 OF 6 REV. D WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/ POLYMIDE INSULATED, NORMAL WEIGHT
43、, SILVER COATED, COPPER CONDUCTOR, 200 C, 600 VOLT, ROHS FINISH WIRE PERFORMANCE CHARACTERISTICS SHALL BE IN ACCORDANCE WITH TABLE 6. TABLE 6 - FINISH WIRE PERFORMANCE CHARACTERISTICS PERFORMANCE CHARACTERISTIC REQUIREMENT MANDREL BEND RESISTANCE (TAPES/BRAIDS) REQUIRED THERMAL SHOCK MECHANICAL RESI
44、STANCE TEMPERATURE EXPOSURE 200 C 2 C (392 F 3.6 F) MAXIMUM CHANGE .091 INCHES WIRE SIZES 26 - 10 MAXIMUM CHANGE .125 INCHES WIRE SIZE 8 - 0000 THERMAL MECHANICAL RESISTANCE (LIFE CYCLE) EXPOSURE 500 HOURS, 230 C 2 C (446 F 3.6 F) HUMIDITY RESISTANCE (IR) 5000 MEGOHMS (MIN)-1000 FEET WIRE SIZES 26 -
45、 10 3000 MEGOHMS (MIN)-1000 FEET WIRE SIZES 8 - 0000 FLUID RESISTANCE DIAMETER INCREASE 5% (MAX) SMOKE RESISTANCE 200 C 5 C (392 F 9 F) FLAME RESISTANCE SELF-EXTINGUISH TIME: 3 SECONDS BURN LENGTH 3 INCHES WET ARC RESISTANCE MINIMUM 67 WIRES PASS WET DIELECTRIC TEST 3 OR LESS WIRES FAIL IN ONE BUNDL
46、E DAMAGE LENGTH: 3.0 INCHES OF LESS DRY ARC RESISTANCE MINIMUM 67 WIRES PASS WET DIELECTRIC TEST 3 OR LESS WIRES FAIL IN ONE BUNDLE DAMAGE LENGTH: 3.0 INCHES OF LESS DYNAMIC CUT-THROUGH WIRE SIZE 26 10 POUNDS AT 23 C, 8 POUNDS AT 150 C, 6 POUNDS AT 200 C WIRE SIZE 20 25 POUNDS AT 23 C, 20 POUNDS AT
47、150 C, 15 POUNDS AT 200 C WIRE SIZE 16 25 POUNDS AT 23 C, 20 POUNDS AT 150 C, 15 POUNDS AT 200 C FORCED HYDROLYSIS INSULATION RESISTANCE WIRE SIZE 20 70 C 2 C (158 F 3.6 F), 5000 HOURS LONGEVITY RESISTANCE (THERMAL INDEX) 200 C 2 C (392 F 3.6 F), 10000 HOURS 7. REQUIREMENT EXCEPTION TO THE AS22759:
48、NONE APPLICATION NOTES 1. PRODUCTS MANUFACTURED TO THIS SPECIFICATION ARE ROHS COMPLIANT. SPECIFICATION NOTES 1. REVISION INDICATOR: A CHANGE BAR (I) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS, NOR IN DOCUMENTS THAT CONTAIN EDITORIAL CHANGES ONLY.