1、 AEROSPACE STANDARD CABLE, POWER, ELECTRICAL, 600 VOLTS, PORTABLE, SINGLE CONDUCTOR, NON-OZONE RESISTANT AS5756/1 Copyright 2017 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic,
2、 mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2004-06RE
3、VISED2011-11REAFFIRMED 2017-12THIRD ANGLE PROJECTION CUSTODIAN: AE-8D REV.A FEDERAL SUPPLY CLASS 6145 AS5756 /1 SHEET 1 OF 2 REV. A PROCUREMENT SPECIFICATION: AS5756 SAE Technical Standards Board Rules provide that: “This report is published by SAEtoadvance thestate of technicaland engineering scien
4、ces. The useof this report is entirely voluntary, and its applicability andsuitability for any particularuse, includingany patent infringement arisingtherefrom,is the sole responsibility of theuser.” SAE reviews eachtechnical reportatleast every fiveyears at whichtime it may be revised, reaffirmed,
5、stabilized, or cancelled. SAE invites your written comments and suggestions.SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AS5756/1A RATIONALE UPDATE REFERENCES NOTICE THE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST
6、 OF THIS SPECIFICATION SHEET AND THE LATEST ISSUE OF: SAE AS5756. FIGURE 1 - CONDUCTOR EXAMPLE REQUIREMENTS (SEE AS5756 AND TABLE 1): CONSTRUCTION FIRST - COPPER CONDUCTOR, SEE TABLE 1 OF AS5756 FOR REQUIREMENTS, SIZES 10 AWG AND SMALLER SHALL BE TIN-COATED, SIZES 8 AWG AND LARGER SHALL BE UNCOATED.
7、 SECOND - SEPARATOR, REQUIRED WHERE UNCOATED CONDUCTORS ARE USED, OPTIONAL WHERE TIN-COATED CONDUCTORS ARE USED. THIRD - INSULATION OF SYNTHETIC OR NATURAL RUBBER (SEE TABLE 1 FOR THICKNESS), COLORED BLACK. FOURTH - JACKET OF SYNTHETIC OR NATURAL RUBBER (SEE TABLE 1 FOR THICKNESS), COLORED BLACK. CA
8、BLE SURFACE MARKING REQUIRED. INSULATION AND JACKET MAY BE COMBINED AT MANUFACTURERS OPTION. OZONE RESISTANCE - NOT REQUIRED. AEROSPACE STANDARD AS5756 /1 SHEET 2 OF 2 REV. A CABLE, POWER, ELECTRICAL, 600 VOLTS, PORTABLE, SINGLE CONDUCTOR, NON-OZONE RESISTANT TABLE 1 - DETAILS OF CONSTRUCTION PART N
9、O. M5756/1 CONDUCTOR SIZE NOMINAL INSULATION THICKNESS (INCH) 1/ NOMINAL JACKET THICKNESS (INCH) 2/ OVERALL DIAMETER OF JACKETED CABLE CONDUCTOR RESISTANCE PER 1000 FEET (MAX) 20C (OHMS) NOMINAL WEIGHT PER 1000 FEET (POUNDS) 3/ MIN (INCHES) MAX (INCHES) -001 18 .031 .0625 .214 .265 7.13 30.7 -002 16
10、 .031 .0625 .225 .277 4.48 35.9 -003 14 .047 .0625 .271 .327 2.82 53.1 -004 12 .047 .0625 .292 .350 1.77 66.3 -005 10 .047 .0625 .317 .375 1.14 88.2 -006 8 .063 .0625 .379 .443 .666 124.5 -007 6 .063 .078 .429 .527 .423 183.1 -008 4 .063 .078 .509 .581 .266 248.2 -009 2 .063 .094 .603 .681 .169 364.
11、7 -010 1 .078 .094 .667 .750 .134 454.5 -011 1/0 .078 .109 .738 .837 .106 562.0 -012 2/0 .078 .125 .819 .954 .0850 710.9 -013 3/0 .078 .125 .913 1.030 .0674 858.3 -014 4/0 .078 .141 1.010 1.130 .0535 1056.3 -015 250 .094 .156 1.080 1.250 .0453 1283.2 1/ THE MINIMUM INSULATION THICKNESS SHALL BE AT L
12、EAST 90% OF THE NOMINAL. 2/ THE MINIMUM JACKET THICKNESS SHALL BE AT LEAST 90% OF THE NOMINAL. 3/ THE NOMINAL WEIGHT IS FOR INFORMATION ONLY. APPLICATIONS: 1. THE CABLES SPECIFIED UNDER THIS DETAIL SPECIFICATION MAY BE INSULATED WITH ANY NUMBER OF INSULATING MATERIALS THAT WILL MEET THE LIMITED PERF
13、ORMANCE REQUIREMENTS OF THIS PARTICULAR DETAIL SPECIFICATION. 2. THERE ARE NO PERFORMANCE REQUIREMENTS FOR WEATHERING OR OZONE RESISTANCE ON WIRE COVERED BY THIS DETAIL SPECIFICATION. THIS CABLE IS NOT RECOMMENDED FOR USE WHERE IT WILL BE EXPOSED TO THESE CONDITIONS. 3. THE CABLES SPECIFIED IN THIS
14、DETAIL SPECIFICATION ARE FOR REPLACEMENT ONLY AND IS NO LONGER AUTHORIZED FOR USE IN AS7974 CABLE ASSEMBLIES (SEE AS5756/2). 4. THIS INSULATION SYSTEM HAS BEEN USED IN AEROSPACE GROUND POWER APPLICATIONS USING 115/200 VOLTS (PHASE TO NEUTRAL) AT 400 HERTZ AC. VERIFICATION OF THE SUITABILITY OF THIS
15、PRODUCT FOR USE IN OTHER ELECTRICAL SYSTEM CONFIGURATIONS IS THE RESPONSIBILITY OF THE USER. SPECIFICATION NOTES 1. A CHANGE BAR ( L ) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS, NOR IN DOCUMENTS THAT CONTAIN EDITORIAL CHANGES ONLY.