1、 _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising ther
2、efrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2016 SAE International All rights reserved. No part of this
3、publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-49
4、70 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J2549_201603 SURFACE VEHICLE STANDARD J2549 MAR2016 Issued 2007-08 Revised 2012-
5、01Reaffirmed 2016-03 Superseding J2549 JAN2012 Single Conductor Cable for Heavy-Duty Applications - Truck and Bus RATIONALE J2549 has been reaffirmed to comply with the SAE five-year review policy. FOREWORD This document is intended as a supplement to the SAE J1127 and SAE J1128 Standards as a means
6、 of assuring the dimensional and performance needs associated with the unique demands of heavy-duty truck, trailer and converter dolly electrical systems. 1. SCOPE This SAE standard establishes the minimum construction and performance requirements for single conductor cable for use on trucks, traile
7、rs and converter dollies. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE Publications Available from SAE International, 400 Com
8、monwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. SAE J1127 Low Voltage Battery Cable SAE J1128 Low Voltage Primary Cable SAE J2394 Seven-Conductor Cable for ABS Power - Truck and Bus SAE INTERNATIONAL J2549 MAR2016 Page
9、 2 of 4 2.1.2 ASTM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org ASTM B 3 Specification for Soft or Annealed Copper Wire 3. DEFINITIONS Refer to the definitions contained in SAE J1127 and SAE J1
10、128. 4. GENERAL 4.1 Cable Types Due to the variation in the performance demands of cables used in different applications within the truck-trailer system, this document addresses various types of cables, determined by their mode of installation and working environment. These are summarized in SAE J11
11、27 and SAE J1128. 4.2 Identification Packaging containing cable conforming to this document shall be identified with the manufacturers identification, and shall be identified with SAE J2549 along with the cable type as described in SAE J1127 and SAE J1128. The cable itself is not to be marked as thi
12、s may conflict with circuit identification marking. 5. GENERAL SPECIFICATIONS 5.1 Conductors 5.1.1 Material All conductors shall be of stranded, soft-annealed copper, complying with ASTM B 3, SAE J1127 and SAE J1128. The surface finish shall be sufficiently free of imperfections to enable effective
13、terminal crimping and splicing. 5.1.2 Cross-Sectional Area The cross-sectional area of stranded conductors shall conform to the values specified in SAE J1127 and SAE J1128. Where a higher current-carrying capacity is required, the user may specify the larger cross-sectional area such as that outline
14、d in SAE J2394, (which covers three popular conductor sizes), after consideration of the effect on terminal crimp dimensions and connectors. 5.1.3 Stranding The individual strands contained within a conductor shall be of the same nominal diameter. The number of strands is dependent on the flexibilit
15、y and flex-life requirements for specific applications with a greater number of strands used in applications involving repeated flexing. 5.1.4 Conductor Splicing If required, conductor splicing shall meet the requirements outlined in SAE J1127 and SAE J1128 as well as those noted below. 5.1.4.1 Sing
16、le strand splices are not to be closer together than 20 times the conductor diameter in a bunched or concentric stranded conductor and 200 times the conductor diameter in a rope-lay construction and there shall be no more than three single strand splices per 3 m of conductor. SAE INTERNATIONAL J2549
17、 MAR2016 Page 3 of 4 5.1.4.2 Whole conductor splices shall not exceed a frequency of one splice per 30 000 m of cable. 5.2 Insulation 5.2.1 Material Physical Properties The physical properties of the insulation for each cable type shall comply with the requirements as outlined in the “Mechanical Pro
18、perties” section of SAE J1127 and SAE J1128. 5.2.2 Application Insulation shall be applied in compliance with SAE J1127 and SAE J1128. The surface finish shall be free of imperfections such as indentations, voids, nicks, cuts and roughness and the eccentricity and perimeter of the cable shall be suf
19、ficiently uniform to enable the effective sealing of standard connectors. 5.2.3 Insulated Conductor Outside Diameter The outside diameter of each insulated conductor shall be measured in accordance with the methods outlined in SAE J1127 and SAE J1128. The mean of the diameter readings shall determin
20、e the finished insulated conductor diameter and shall be in accordance with SAE J1127 and SAE J1128 except where identified in Table 1. 5.2.4 Wall Thickness The minimum wall thickness at any point shall be measured in accordance with the method outlined in SAE J1127 and SAE J1128. All individual wal
21、l thickness values must be in accordance with SAE J1127 and SAE J1128 except where identified in Table 1. 6. TESTS 6.1 Test Methods All tests shall be performed in accordance with the methods outlined in SAE J1127 and SAE J1128. 6.2 Performance Requirements Cable shall comply with all of the perform
22、ance and durability requirements outlined in SAE J1127 and SAEJ1128. 7. NOTES 7.1 Marginal Indicia A change bar (l) located in the left margin is for the convenience of the user in locating areas where technical revisions, not editorial changes, have been made to the previous issue of this document.
23、 An (R) symbol to the left of the document title indicates a complete revision of the document, including technical revisions. Change bars and (R) are not used in original publications, nor in documents that contain editorial changes only. SAE INTERNATIONAL J2549 MAR2016 Page 4 of 4 Table 1 - Outsid
24、e Diameter and Minimum Wall Thickness (REFERENCE 5.2.3 AND 5.2.4) Wire Wire Min. Max Min. Max Min. Max Min. Max Min. Max Min. MaxSize Size Wall OD Wall OD Wall OD Wall OD Wall OD Wall ODmm2AWGmmmm in in mmmm in in mmmm in in0.22 24 0.29 1.50 0.012 0.0610.35 22 0.29 1.70 0.012 0.0680.5 20 0.29 1.90 0
25、.012 0.075 0.47 2.29 0.019 0.090 0.62 2.57 0.025 0.1010.8 18 0.29 2.11 0.012 0.083 0.47 2.41 0.019 0.095 0.65 2.82 0.026 0.111116 0.46 2.82 0.018 0.111 0.69 3.18 0.027 0.125214 0.46 3.07 0.018 0.121 0.76 3.68 0.030 0.145312 0.53 3.66 0.021 0.144 0.81 4.27 0.032 0.1685100.37 4.06 0.015 0.160 0.65 4.5
26、2 0.026 0.178 0.90 5.00 0.036 0.197880.42 4.90 0.017 0.193 0.80 5.69 0.032 0.224 0.95 5.84 0.038 0.230Wire Wire Min. Max Min. Max Min. Max Min. MaxSize Size Wall OD Wall OD Wall OD Wall ODmm2AWGmmmm in in mmmm in in13 6 0.86 7.54 0.034 0.297 1.14 8.48 0.045 0.334SAE TWP TXL GPT GXL SXL- per SAE J1128 - - per SAE J1128 - per SAE J1128 - - per SAE J1128 -SGT SGX SGR - per SAE J1128 - per SAE J1128 - per SAE J1128 -SAE STT STX STR. PREPARED BY THE SAE TRUCK AND BUS ELECTRICAL SYSTEMS COMMITTEE
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1