1、 TIA TELECOMMUNICATIONS SYSTEMS BULLETIN Telecommunications Telephone Terminal Equipment U. S. Network Connections Regulatory Approval Guide - Addendum 1 TSB-129-A-1 (Addendum No. 1 to TSB-129-A) APRIL 2003 TELECOMMUNICATIONS INDUSTRY ASSOCIATION The Telecommunications Industry Association represent
2、s the communications sector of Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTICE TIA Engineering Standards and Publications are designed to serve the public interest throug
3、h eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall
4、not in any respect preclude any member or nonmember of TIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than TIA members, whether the standard is to be
5、used either domestically or internationally. Standards, Publications and Bulletins are adopted by TIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever t
6、o parties adopting the Standard, Publication, or Bulletin. Further details of the development process are available in the TIA Engineering Manual, located at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm Technical Bulletins are distinguished from TIA Standards or Documents, in that th
7、ey contain a compilation of engineering data or information useful to the technical community, and represent approaches to good engineering practices that are suggested by the formulating committee. This Bulletin is not intended to preclude or discourage other approaches that similarly represent goo
8、d engineering practice, or that may be acceptable to, or have been accepted by, appropriate bodies. Parties who wish to bring other approaches to the attention of the formulating committee to be considered for inclusion in future revisions of this Bulletin are encouraged to do so. It is the intentio
9、n of the formulating committee to review this document every five years, but it maybe revised and updated at any time as may be occasioned by changes in technology, industry practice, or government regulations, or for other appropriate reasons. (From Project No. 3-0017-AD1, formulated under the cogn
10、izance of the TIA TR-41.11 Subcommittee on Administrative Regulatory Considerations.) . Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION 2003 Standards and Technology Department 2500 Wilson Boulevard Arlington, VA 22201 U.S.A. PRICE: Please refer to current Catalog of TIA TELECOMMUNICATIONS INDU
11、STRY ASSOCIATION STANDARDS AND ENGINEERING PUBLICATIONS or call Global Engineering Documents, USA and Canada (1-800-854-7179) International (303-397-7956) or search online at http:/www.tiaonline.org/standards/search_n_order.cfm All rights reserved Printed in U.S.A. Copyright Telecommunications Indus
12、try Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTICE OF DISCLAIMER AND LIMITATION OF LIABILITY The document to which this Notice is affixed (the “Document”) has been prepared by one or more Engineering Committ
13、ees or Formulating Groups of the Telecommunications Industry Association (“TIA”). TIA is not the author of the Document contents, but publishes and claims copyright to the Document pursuant to licenses and permission granted by the authors of the contents. TIA Engineering Committees and Formulating
14、Groups are expected to conduct their affairs in accordance with the TIA Engineering Manual (“Manual”), the current and predecessor versions of which are available at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm. TIAs function is to administer the process, but not the content, of docu
15、ment preparation in accordance with the Manual and, when appropriate, the policies and procedures of the American National Standards Institute (“ANSI”). TIA does not evaluate, test, verify or investigate the information, accuracy, soundness, or credibility of the contents of the Document. In publish
16、ing the Document, TIA disclaims any undertaking to perform any duty owed to or for anyone. The use or practice of contents of this Document may involve the use of intellectual property rights (“IPR”), including pending or issued patents, or copyrights, owned by one or more parties. TIA makes no sear
17、ch or investigation for IPR. When IPR consisting of patents and published pending patent applications are claimed and called to TIAs attention, a statement from the holder thereof is requested, all in accordance with the Manual. TIA takes no position with reference to, and disclaims any obligation t
18、o investigate or inquire into, the scope or validity of any claims of IPR. TIA does not enforce or monitor compliance with the contents of the Document. TIA does not certify, inspect, test or otherwise investigate products, designs or services or any claims of compliance with the contents of the Doc
19、ument. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE CONTENTS, ITS FITNESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NON-INFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPE
20、RTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE CONTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE RE
21、FERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUE
22、NTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMA
23、GES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license fro
24、m IHS-,-,-PLEASE! DONT VIOLATETHELAW!This document is copyrighted by the TIA and may not be reproduced without prior permission of the Telecommunications Industry Association. For information consult our website at http:/www.tiaonline.org/about/faqDetail.cfm?id=18 Organizations may obtain permission
25、 to reproduce a limited number of copies through entering into a license agreement. For information, contact: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 U.S.A. or call U.S.A. and Canada 1-800-854-7179, International (303) 397-7956 Copyright Telecommunications Industr
26、y Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TSB-129-A-1iTable of Contents1. INTRODUCTION 12. SCOPE13. CLAUSE REVISIONS.26.2 TEST LABORATORY REQUIREMENTS.26.3 TEST PROCEDURES.28.4.4 SDOC FILINGS WITH THE ACTA D
27、ATABASE 28.6.2 IMPORTATION FOR SALE .2E.2 DETAILED DESCRIPTIONS OF REQUIRED INFORMATION 2Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TSB-129-A-1iiSuggestions for improvement
28、 of this document are welcome. They should be sent to:Telecommunications Industry AssociationStandards and Technology DepartmentSuite 3002500 Wilson BoulevardArlington, VA 22201Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or ne
29、tworking permitted without license from IHS-,-,-TSB-129-A-111. INTRODUCTIONThe purpose of this addendum is to correct certain references in TIA/TSB-129-A. Theserevisions are identified in the following text with additions shown in bold italics anddeletions shown as strikeout. Other paragraphs in the
30、 clause, or in TIA/TSB-129-A that arenot shown remain the same. The section numbering in section 3 of this document alignswith the original sections in TIA/TSB-129-A.2. SCOPEThis addendum only provides corrections to TIA/TSB-129-A, “Telecommunications -Telephone Terminal Equipment - U.S. Network Con
31、nections Regulatory Approval Guide.”Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TSB-129-A-123. CLAUSE REVISIONS6.2 Test Laboratory RequirementsAdditional credentials, such a
32、s NVLAP, A2LA, or ISO/IEC 17025 accreditation, mayalso prove useful in assessing the competency of a test laboratory. Furthermore, theResponsible Party must obtain a description of the measurement facilities and thetest plan employed by the test lab, and retain this information on file for futureref
33、erence (see FCC rules in Section 68.346). The ACTA may require that certaininformation be included in this description. A copy of this description should be filedwith the first submission to the ACTA. If this description changes it should be filedwith the next submission to the ACTA (see below).6.3
34、Test ProceduresUnder the SDoC method, the FCC requires each Responsible Party must ensure toretain a copy of the procedures used to test TTE for conformance to the technicalcriteria. is on file with the ACTA This requirement applies whether the ResponsibleParty does the testing itself or relies on r
35、esults provided by an independentlaboratory.8.4.4 SDoC Filings with the ACTA DatabaseACTA requires Responsible parties Parties filing a SDoC to must provide thefollowing to the ACTA for all types of filings.f) Copy of Part 68 Test Procedures: Unless on file and current, a copy of the testprocedures
36、used to verify conformity must be submitted. Any deviations from thesetest procedures must be noted.8.6.2 Importation for SaleAs described in paragraph 5.1.1 the FCC requires that the Responsible Party underthe SDoC Method, the RP must be resident maintain an agent for service in theU.S.E.2 Detailed
37、 Descriptions of Required InformationFICDescription02RV2.T2-wire loop reverse battery signaling, loop closure from customer LEC,reverse battery from LEC customer, 600 ohms. Used for Direct InwardDialing (DID) ports.04RV2.T2 4-wire loop reverse battery signaling, loop closure from customer LEC,revers
38、e battery from LEC customer, 600 ohms. Used for Direct InwardDialing (DID) ports.# # #Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-