1、 TIA DOCUMENT FOTP-187 Engagement and Separation Force Measurement of Fiber Optic Connector Sets TIA-455-187 ANSI APPROVAL WITHDRAWN MARCH, 2004 JULY 1991 TELECOMMUNICATIONS INDUSTRY ASSOCIATION The Telecommunications Industry Association represents the communications sector of NOTICE TIA Engineerin
2、g Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product
3、 for their particular need. The existence of such Publications shall not in any respect preclude any member or non-member of TIA from manufacturing or selling products not conforming to such Publications. Neither shall the existence of such Documents preclude their voluntary use by non-TIA members,
4、either domestically or internationally. TIA DOCUMENTS TIA Documents contain information deemed to be of technical value to the industry, and are published at the request of the originating Committee without necessarily following the rigorous public review and resolution of comments which is a proced
5、ural part of the development of a American National Standard (ANS). Further details of the development process are available in the TIA Engineering Manual, located at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm TIA Documents shall be reviewed on a five year cycle by the formulating
6、Committee and a decision made on whether to reaffirm, revise, withdraw, or proceed to develop an American National Standard on this subject. Suggestions for revision should be directed to: Standards & Technology Department, Telecommunications Industry Association, 2500 Wilson Boulevard, Arlington, V
7、A 22201 U.S.A. (From Project No. 3-3749, formulated under the cognizance of the TIA FO-4 Committee on Fiber Optics.) Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION 2004 Standards & Technology Department 2500 Wilson Boulevard Arlington, VA 22201 U.S.A. PRICE: Please refer to current Catalog of
8、TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION STANDARDS AND ENGINEERING PUBLICATIONS or call Global Engineering Documents, USA and Canada (1-800-854-7179) International (303-397-7956) or search online at http:/www.tiaonline.org/standards/search_n_order.cfm All rights reserved Printed in U.S.A. NOTICE
9、OF DISCLAIMER AND LIMITATION OF LIABILITY The document to which this Notice is affixed (the “Document”) has been prepared by one or more Engineering Committees or Formulating Groups of the Telecommunications Industry Association (“TIA”). TIA is not the author of the Document contents, but publishes
10、and claims copyright to the Document pursuant to licenses and permission granted by the authors of the contents. TIA Engineering Committees and Formulating Groups are expected to conduct their affairs in accordance with the TIA Engineering Manual (“Manual”), the current and predecessor versions of w
11、hich are available at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm. TIAs function is to administer the process, but not the content, of document preparation in accordance with the Manual and, when appropriate, the policies and procedures of the American National Standards Institute (
12、“ANSI”). TIA does not evaluate, test, verify or investigate the information, accuracy, soundness, or credibility of the contents of the Document. In publishing the Document, TIA disclaims any undertaking to perform any duty owed to or for anyone. The use or practice of contents of this Document may
13、involve the use of intellectual property rights (“IPR”), including pending or issued patents, or copyrights, owned by one or more parties. TIA makes no search or investigation for IPR. When IPR consisting of patents and published pending patent applications are claimed and called to TIAs attention,
14、a statement from the holder thereof is requested, all in accordance with the Manual. TIA takes no position with reference to, and disclaims any obligation to investigate or inquire into, the scope or validity of any claims of IPR. TIA does not enforce or monitor compliance with the contents of the D
15、ocument. TIA does not certify, inspect, test or otherwise investigate products, designs or services or any claims of compliance with the contents of the Document. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE C
16、ONTENTS, ITS FITNESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NON-INFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REG
17、ARDING THE CONTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE REFERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRE
18、CT, ARISING FROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH
19、OF WARRANTY, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. PLEAS
20、E! DONT VIOLATE THE LAW! This document is copyrighted by the TIA and may not be reproduced without prior permission of the Telecommunications Industry Association. For information consult our website at http:/www.tiaonline.org/about/faqDetail.cfm?id=18 Organizations may obtain permission to reproduc
21、e a limited number of copies through entering into a license agreement. For information, contact: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 U.S.A. or call U.S.A. and Canada 1-800-854-7179, International (303) 397-7956 STD.EIA TIA-VsS-LA7-ENGL 1771 3234bC0 b/V532 52T
22、 W EIA/TIA-455-187 Page 1 FOTP-187 KNGAGEMENT AND SEpARATiON FORCE MEASUREMENT OF FIBER OPTIC CONNEcrOR SETS (From EIA Standards Proposal No. 2352, formulated under the cognizance of TIA FO-6.3, Subcommittee on Fiber Optic Interconnecting Devices, and TIA FO-6.4, Subcommittee on Fiber Optic Test Met
23、hods and Instrumentation.) This FOTP is part of the series of test procedures included within Recommended Standard EIA/TIA-455. 1. NTRODUCTION 1.1 Intent The purpose of this procedure is to measure the forces or torques that are required to fully couple or uncouple a connector set. 1.2 Description T
24、he connector set components are held in a fixture SO that a controlled coupling force or torque can be applied. The force or torque is measured during the entire coupling and/or uncoupling cycle. The procedure is applicable to either twist type or push-pull type coupling mechanisms. 1.3 Alternative
25、Procedures This test procedure is an alternative to the measurement procedure, titled Engagement and Separation Force of IEC 874-1, Third Edition. EIA/TIA-455-187 Page 2 2. APPLICABLE DOCUMENTS The following standards contain provisions which, through reference in this text, constitute provisions of
26、 this procedure. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this procedure are encouraged to apply the most recent editions of the referenced standards. EIA/TIA- 45 5 -A1 “Standard Test Procedures for Fiber
27、 Optic Fibers, Cables, Transducers, Sensors, Connecting and Terminating Devices, and Other Fiber Optic Components “Connectors for optical fibres and Cables, Part 1, Generic Specif icationll 2 IEC 874-1, Third Edition 3. APPARATUS The apparatus consists of a holding fixture( s) , a force or torque ge
28、nerator, and a force or torque measuring instrument. 3.1 Holding Future(s) The holding fixture shall hold the mating components so that they do not influence the measured force or torque value. They shall maintain mating components in proper alignment throughout the coupling cycle. 3.2 Force or Torq
29、ue Generator The force or torque generator shall smoothly apply the force or torque. Hand coupling of the connectors is permitted. 3.3 Force or Torque Measuring Instrument The measuring instrument shall continuously measure the force or torque throughout the coupling cycle. In process of preparation
30、. Pending publication of this revision, use EIA RS-455. in process of preparation. Pending publication of this revision, use IEC/86B(Central Officel69. STD-EIA TIA-455-187-ENGL 1991 323b00 ObL453Y 3T2 EIA/TIA-455-187 Page 3 4. SAWLING AND SPECIMENS 4.1 Sampling. Unless otherwise specified in the Det
31、ail Specification, select the test specimens randomly from the lot(s) being tested and according to the schedule in the Detail Specification. 4.2 specimens. The Detail Specification shall define the specimen. 5.1 Preconditioning Precondition the specimen as required by the Detail Specification. 5.2
32、Measurement 5.2.1 Position the connector set components in the holding fixture. 5.2.2 Apply and measure the force or torque to couple the connector set. Unless otherwise specified, the minimum allowable coupling time is 3 seconds. 5.2.3 Apply and measure the force or torque to uncouple the connector
33、 set. Unless otherwise specified, the minimum allowable uncoupling time is 3 seconds. 6. CALCULATIONS OR INTERPREI?A!ON OF RESULTS This Section is not applicable to this procedure. EIA/TIA-455-187 Page 4 7.1 As a minimum, the documentation shall provide the following information: 7.1.1 Title of meas
34、urement and date. 7.1.2 Specimen description and the measured feature. The description shall contain the specimen variant identification number, when applicable. 7.1.3 The apparatus used and the date of latest calibration. 7.1.4 All applicable measurement details (see Section 8). 7.1.5 All measureme
35、nt values and observations. 7.2 The following information shall be reported and available only for U.S. Military applications: 7.2.1 Test personnel. 8 SPECIFICATION INFORMATiON The Detail Specification shall specify the following details, as applicable: . 8.1 8.2 The maximum and/or minimum allowable
36、 coupling force or torque (5.2.2). A definition of the specimen to be tested (see Section 4.). 8.3 The maximum and/or minimum allowable uncoupling force or torque (5.2.3). 8.4 The minimum allowable coupling time (5.2.2) or uncoupling time (5.2.3), if other than stated in 5.2.2 or 5.2.3. 8.5 Precondi
37、tioning procedure required (5.1) . 8.6 All deviations from this procedure. I EIA/TIA-455-187 Page 5 APPENDIX COMPARISON BE3MEEN !i!HIS FTP AND IEC OR CCITT REQREMENTS (Nonmandatory Information) Al. IEC Reference is made to IEC-874-1, Third Edition 3 , “Connectors for optical fibres and cables, Part
38、1: Generic specification.11 IEC-874-1, Third Edition, defines a measurement procedure titled Engagement and Separation Force, that is, insofar as can be determined, the same as the test defined in FOTP-187. It is believed that this IEC method was originally created to test electrical connectors and was later adapted to fiber optic connectors. A2. CCITT There are no references to any test equivalent to this FOTP known to exist in CCITT documents. in process of preparation. Pending publication of this revision, the test can be found in Clause 4.4.5 of IEC/86B(Central Officel69.