1、 TIA-604-10-B (Revision of TIA-604-10-A) August 2008FOCIS 10B Fiber Optic Connector Intermateability Standard- Type LC ANSI/TIA-604-10-B-2008 APPROVED: AUGUST 25, 2008 REAFFIRMED: MARCH 30, 2015 NOTICE TIA Engineering Standards and Publications are designed to serve the public interest through elimi
2、nating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Standards and Publications shall n
3、ot in any respect preclude any member or non-member of TIA from manufacturing or selling products not conforming to such Standards and Publications. Neither shall the existence of such Standards and Publications preclude their voluntary use by Non-TIA members, either domestically or internationally.
4、 Standards and Publications are adopted by TIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This St
5、andard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its
6、 use. Any use of trademarks in this document are for information purposes and do not constitute an endorsement by TIA or this committee of the products or services of the company. (From Standards Proposal No.3-4133-RV2-RF1-2, formulated under the cognizance of the TIA TR-42 Telecommunications Cablin
7、g Systems, TR-42.13 Subcommittee on Passive Optical Devices and Fiber Optic Metrology). Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION Technology and Standards Department 1320 N. Courthouse Road, Suite 200 Arlington, VA 22201 U.S.A. PRICE: Please refer to current Catalog of TIA TELECOMMUNICATI
8、ONS INDUSTRY ASSOCIATION STANDARDS AND ENGINEERING PUBLICATIONS or call IHS, USA and Canada (1-877-413-5187) International (303-397-2896) or search online at http:/www.tiaonline.org/standards/catalog/ All rights reserved Printed in U.S.A. NOTICE OF COPYRIGHT This document is copyrighted by the TIA.
9、Reproduction of these documents either in hard copy or soft copy (including posting on the web) is prohibited without copyright permission. For copyright permission to reproduce portions of this document, please contact the TIA Standards Department or go to the TIA website (www.tiaonline.org) for de
10、tails on how to request permission. Details are located at: http:/www.tiaonline.org/standards/catalog/info.cfm#copyright or Telecommunications Industry Association Technology (b) there is no assurance that the Document will be approved by any Committee of TIA or any other body in its present or any
11、other form; (c) the Document may be amended, modified or changed in the standards development or any editing process. The use or practice of contents of this Document may involve the use of intellectual property rights (“IPR”), including pending or issued patents, or copyrights, owned by one or more
12、 parties. TIA makes no search or investigation for IPR. When IPR consisting of patents and published pending patent applications are claimed and called to TIAs attention, a statement from the holder thereof is requested, all in accordance with the Manual. TIA takes no position with reference to, and
13、 disclaims any obligation to investigate or inquire into, the scope or validity of any claims of IPR. TIA will neither be a party to discussions of any licensing terms or conditions, which are instead left to the parties involved, nor will TIA opine or judge whether proposed licensing terms or condi
14、tions are reasonable or non-discriminatory. TIA does not warrant or represent that procedures or practices suggested or provided in the Manual have been complied with as respects the Document or its contents. If the Document contains one or more Normative References to a document published by anothe
15、r organization (“other SSO”) engaged in the formulation, development or publication of standards (whether designated as a standard, specification, recommendation or otherwise), whether such reference consists of mandatory, alternate or optional elements (as defined in the TIA Procedures for American
16、 National Standards) then (i) TIA disclaims any duty or obligation to search or investigate the records of any other SSO for IPR or letters of assurance relating to any such Normative Reference; (ii) TIAs policy of encouragement of voluntary disclosure (see TIA Procedures for American National Stand
17、ards Annex C.1.2.3) of Essential Patent(s) and published pending patent applications shall apply; and (iii) Information as to claims of IPR in the records or publications of the other SSO shall not constitute identification to TIA of a claim of Essential Patent(s) or published pending patent applica
18、tions. TIA does not enforce or monitor compliance with the contents of the Document. TIA does not certify, inspect, test or otherwise investigate products, designs or services or any claims of compliance with the contents of the Document. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING
19、 WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE CONTENTS, ITS FITNESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NONINFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR
20、THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE CONTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE REFERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE
21、CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFIT
22、S, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND T
23、HESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. TIA/EIA-604-10BiFOCIS 10BFIBER OPTIC CONNECTOR INTERMATEABILITY STANDARDTYPE LCCONTENTS1 INTRODUCTION 12 ADAPTER STANDARD 33 PLUG STANDARD 54 APPLICATION 85 POLARIZATION MAINTENANCE 8TIA/EIA-604-10BiiBLANK PAGETIA/EIA-604-10B1FOCI
24、S 10BFIBER OPTIC CONNECTOR INTERMATEABILITY STANDARD1 Introduction1.1 ScopeFOCIS 10B presents the intermateability standard for simplex and duplex connectorswith the commercial designation LC, and is issued as an addendum to TIA/EIA 604,Fiber Optic Connector Intermateability Standards. The provision
25、s of TIA/EIA 604 applyto this document.1.2 ObjectiveIntermateability standards define the minimum physical attributes of mating connectorcomponents. Fully dimensioned components are not within the scope or intent of FOCIS10B.The requirements in FOCIS 10B have been selected with the objective of ensu
26、ring thatany combination of plugs and adapters conforming to the requirements of FOCIS 10Bwill mechanically intermate, and that intermated connector assemblies will meet acommon level of performance.The common level of performance of an intermated connector assembly is the leastdemanding set of perf
27、ormance requirements in the separate performance specificationsof each of the products in the assembly; see TIA/EIA 604.1.3 LimitationsRealization of the objectives for FOCIS 10B may be limited by the followingconsiderations:1.3.1 Configuration OptionsThere are configuration options for both plugs a
28、nd adapters in FOCIS 10B that imposelimitations on the combinations of plugs and adapters that should be selected in aconnector assembly. For plugs to be inserted in the adapter, the key option, k, for both plugs must becompatible with the keying option of the adapter Both plugs should have the same
29、 ferrule diameter option, t. An assembly withdifferent diameter options may have a higher loss than anticipated. Both plugs should have the same angle of contact option, a. An increase in loss maybe expected if the plugs with different options are mated, and the polish on theferrule may be damaged.T
30、IA/EIA-604-10B21.3.2 Common performanceThe following considerations limit the application of common performance: The location of the optical cores, figure 3.2.3a, and the apex offsets, clause 3.2.5,are defined, without tolerances, by their true positions. To achieve commonperformance, the distributi
31、ons of the actual positions of these features should becentered on their respective true positions. Tuning of the connector plugs may improve performance when plugs are mated withplugs that have been similarly tuned. Tuning, however, offsets the cores relative tothe center of the ferrule and common
32、performance can not be expected betweentuned plugs and untuned plugs. Tuned plugs are assembled so the offset of the fiberfalls in a preferred location with respect to the key; see clause 3.2.8. As analternative to tuning for fiber offset, plugs could be tuned for apex offset. This standard does not
33、 control the intrinsic loss that may occur between fibers in aconnector assembly. Intrinsic loss between fibers must be added to the basicconnector loss.1.3.3 ResolutionCases of combinations of plugs and adapters where mechanical intermateability or thecommon level of performance is not achieved sho
34、uld be resolved through thecooperation of the user and the connector and adapter manufacturer(s).1.4 Drawing practicesTo be in compliance with ANSI and ISO Engineering Practices, the following shall apply:1. Where the tolerance of form is not specified, the limits of the dimensions for afeature cont
35、rol the form as well as the size. The combined effects of size andform variations may not exceed the envelope of perfect form at the maximummaterial condition (MMC).2. Where interrelated features of size (features shown with a common axis orcenter plane) have no geometric tolerance of location or ru
36、nout specified, thelimits of the dimensions for a feature control the location tolerance as well as thesize. When interrelated features are at the MMC, they shall be perfectly locatedrelative to each other as indicated by the drawing.3. Where perpendicular features (features shown at right angles) h
37、ave nogeometric tolerance of orientation or runout specified, the limits of thedimensions for a feature control the orientation tolerance as well as the size.When perpendicular features are at the MMC, they shall be perfectly oriented toeach other as indicated by the drawing.4. As the size of a feat
38、ure departs from the MMC, variations in form, location andorientation are permissible.TIA/EIA-604-10B32 Adapter Standard2.1 Adapter designationThe designation for FOCIS 10B adapter isFOCIS 10B-A-n-k-mwhereA designates an adaptern is the number of fibersk defines the keying configurationm defines the
39、 mounting configuration2.2 Adapter requirementsFOCIS 10B adapters shall meet the requirements of this section.2.2.1 Adapter interface dimensionsThe dimensional requirements for FOCIS 10B adapters are defined as follows:n = 1 Figure 2.2.1a, Simplex adapter interface and Figure 2.2.1b Simplexjunior ad
40、apter interfacen = 2 Figure 2.2.1c, Duplex adapter interface2.2.2 Adapter sleevesThe adapter sleeve is a split (resilient), and the sleeve may be either fixed or floatingwithin the adapter. The minimum inside diameter of the sleeve is specified by the forcerequired to remove a gage pin from a sleeve
41、. The force required to remove a gage pinfrom the sleeve in FOCIS 10B adapter shall be 1.0 N to 2.5 N. The procedures of FOTP158 shall be used to measure the withdrawal force. The pin gauge shall be as defined inFigure 2.2.2The maximum inside diameter of a sleeve is in effect limited by the common l
42、evel ofperformance that the adapter is to achieve.TIA/EIA-604-10B42.2.3 Adapter keying optionsKeying refers to differences in the interface between FOCIS 10B plugs and adaptersthat affect the ability of plugs and adapters to be connected or that alter theperformance of the resulting connector assemb
43、ly.The keying interfaces have been defined:k = 1 Figure 2.2.1a, Senior Adapter Halfk = 2. Figure 2.2.1b. Junior Adapter HalfAdapters can be made with either, k = 1 and k = 1 adapter halves or k = 1 and k = 2.adapter halves. Adapters with k = 1 and k = 2 is mounted so the k = 2 half is mountedbehind
44、the panel protected from mechanical elements. Adapter with k = 2 / k = 2 optionis not recognized as FOCIS 10B compliant.2.2.4 Adapter mounting optionsThe adapter mounting options are defined in Table 2.Table 2 - Adapter optionsAdapterMountingOptionType of mountingm = 0 Unspecified mountingm = 1 Simp
45、lex Snap-in Flange Mountingm = 2 Duplex Snap-in Flange Mountingm = 3 Duplex Snap-in Flange Mounting compatible with FOCIS 3A m = 3m = 4 Duplex Snap-in Flange Mounting compatible with FOCIS 3A m = 1 and m = 2Adapters whose mounting features are not defined are identified with the option m = 0.The dim
46、ensions of the surfaces of the adapter that interface with the mounting panel aredefined by the cutouts in the panel on which the adapter is mounted.FOCIS 10B adapters for m = 1, m = 2, m = 3, and m = 4 shall be capable of beingmounted on panels with the dimensions in Figure 2.2.4.TIA/EIA-604-10B53
47、Plug standard3.1 Plug designationThe complete designation for FOCIS 10B connector plug is:FOCIS 10B P-d-n-k-t-awhereP designates a plugd defines the plug designn is the number of fibersk defines the keying arrangementt defines the ferrule diametera is the angle of contact3.2 Plug requirementsFOCIS 1
48、0B plugs shall meet the requirements of this section.3.2.1 Plug interface optionThere are two plug interface option for FOCIS 10B plugs. The requirement for each ofthese interface options are:d = 1 The elements of the plug that control the interface with the adapter, forplugs offered under this opti
49、on, must meet the dimensional requirementsof figure 3.2.3a Simplex plug interface (d=1).d = 2 The elements of the plug that control the interface with the adapter, forplugs offered under this option, must meet the dimensional requirementsof figure 3.2.3b, Duplex plug interface (d=2).3.2.2 Ferrule diameter optionFerrule diameters for FOCIS 10B plugs are specified in Table 3.Table 3 - Ferrule diametertMinimum(mm)Maximum(mm) Fiber1 1.2483 1.2495 Singlemode2 1.2485 1.2495 Singlemode3 1.2467 1.2495 MultimodeThe ferrule tolerance t = 1 and t = 2 is typically applied to plugs with
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有