1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): DMLWStandard Number: UL 1017Edition Date: September 10, 2010Edition Number: 8Section / Paragraph Reference: Figure 25Subject: Correction of Figure 25 Probe M
3、easurement “D”DECISION:This is generated text for figtxt.A - Upper arm circumference - female - 5th percentile = 11.9 cm (4.685 in)B - Shoulder to elbow length - male - 95th percentile = 16.8 cm (6.61 in)C - Forearm circumference - female - 5th percentile = 12.1.cm (4.76 in)D - Lower arm length - ma
4、le - 95th percentile = 22.7 cm (8.76 8.94 in) (elbow to fingertip)E - Minimum hand clearance diameter - female - 5th percentile = 3.49 cm (1.374 in)Figure 25 - Accessibility probe for openings 1.375 in (34.9 mm) or more(See Clause 4.21.3.1, Annex B Tables B.1 and B.2 and Figure 26)UL COPYRIGHTED MAT
5、ERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULF - Hand length - male - 95th percentile = 10.2 cm (4.016 in)G1 - Middle finger length - male - 95th percentile = 4.5 cm (1.772 in)G2 - Middle finger diameter - female - 5th percentile = 0.79 cm (0.311 in)All dime
6、nsions apply to the 13 - 18 month age bracket (male and female).See http:/ovrt.nist.gov/projects/anthrokids/child.html for more details.RATIONALE FOR DECISION:This Certification Requirement Decision documents a correction to the probe measurement “D” in Figure25. The 22.7 cm dimension is correct, bu
7、t the inch conversion measurement is incorrect. This reflectspresent practice regarding the application of this requirement.Copyright 2012 Underwriters Laboratories Inc.UL, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Re
8、quirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of Underwriters Laboratories Inc. inpractically applying the requirements of the standard. They do not represent formal interpretations of thestandard under Ameri
9、can National Standards Institute (ANSI) processes. UL shall not be responsible toanyone for the use of or reliance upon Certification Requirement Decisions by anyone. UL shall not incurany obligation or liability for damages, including consequential damages, arising out of or in connectionwith the use or reliance upon Certification Requirement Decisions. The electronic version of theCertification Requirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 1017 -2-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1