1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL 1037Antitheft Alarms and DevicesUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPR
2、ODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL Standard for Safety for Antitheft Alarms and Devices, UL 1037Fifth Edition, Dated February 24, 1999Summary of TopicsRevision pages are being issued to reflect the recent reaffirmation of UL 1037 as anAmerican National Standard.Text that has been c
3、hanged in any manner or impacted by ULs electronic publishing system is markedwith a vertical line in the margin. Changes in requirements are marked with a vertical line in the marginand are followed by an effective date note indicating the date of publication or the date on which thechanged require
4、ment becomes effective.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this Standard as is without warranty
5、 of any kind, either expressed or implied, including butnot limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or
6、 any other damages arising out of the use of or theinability to use this Standard, even if UL or an authorized UL representative has been advised of thepossibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid forthis Standard, regardless of the form of th
7、e claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is stor
8、ing an electronicStandard on the purchasers computer system.The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, figures,and/or other elements of the Standard having future effective dates as indicated in the note following theaffected item. The prior t
9、ext for requirements that have been revised and that have a future effective dateare located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice.DECEMBER 31, 2009 UL 1037 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL
10、DECEMBER 31, 2009 UL 1037tr2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFEBRUARY 24, 1999(Title Page Reprinted: December 31, 2009)1UL 1037Standard for Antitheft Alarms and DevicesFirst Edition July, 1974Second Edition J
11、une, 1981Third Edition December, 1988Fourth Edition July, 1994Fifth EditionFebruary 24, 1999This ANSI/UL Standard for Safety consists of the Fifth Edition including revisionsthrough December 31, 2009.The most recent designation of ANSI/UL 1037 as a Reaffirmed American NationalStandard (ANS) occurred
12、 on December 31, 2009. ANSI approval for a standarddoes not include the Cover Page, Transmittal Pages, Title Page, or effective dateinformation.Comments or proposals for revisions on any part of the Standard may besubmitted to UL at any time. Proposals should be submitted via a ProposalRequest in UL
13、s On-Line Collaborative Standards Development System (CSDS)at http:/.ULs Standards for Safety are copyrighted by UL. Neither a printed nor electroniccopy of a Standard should be altered in any way. All of ULs Standards and allcopyrights, ownerships, and rights regarding those Standards shall remain
14、thesole and exclusive property of UL.COPYRIGHT 2009 UNDERWRITERS LABORATORIES INC.ANSI/UL 1037-2004 (R2009)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNOVEMBER 16, 2004ANTITHEFT ALARMS AND DEVICES - UL 10372No Text on This PageUL COPYRIGHT
15、ED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .72 General 72.1 Components .72.2 Units of measurement .82.3 Undated references .82.4 Terminology .83 Glossary .84 Installation and Operating Instructions .9CONSTRUCTION ALL PRODU
16、CTSASSEMBLY5 General .105.1 Product assembly .105.2 Electrical protection 106 Protection of Service Personnel .147 Enclosures 147.1 General 147.2 Doors and covers .167.3 Enclosure openings 167.4 Screens and expanded metal .177.5 Cast metal 187.6 Sheet metal 187.7 Product enclosure mounting 207.8 Pol
17、ymeric materials 228 Electric Shock .229 Corrosion Protection .23FIELD WIRING CONNECTIONS10 General 2311 Cord Connected Products .2312 Permanently Connected Products .2412.1 General .2412.2 Field wiring terminals .2412.3 Field wiring leads .2712.4 Polarity identification 2813 Grounding .28INTERNAL W
18、IRING14 General 2915 Wiring Methods .2916 Separation of Circuits .3017 Bonding for Grounding 31NOVEMBER 16, 2004 ANTITHEFT ALARMS AND DEVICES - UL 1037 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCOMPONENTS, ELECTRICAL18 General 3418.1 Mo
19、unting of components 3418.2 Insulating materials .3518.3 Fuseholders .3518.4 Current-carrying parts .3518.5 Power on indicator .3619 Overcurrent Protection 3620 Semiconductors 3621 Switches .3622 Transformers and Coils 36SPACINGS23 General 3724 Components .39PERFORMANCE ALL PRODUCTS25 General 4025.1
20、 Test units and data .4025.2 Test samples and miscellaneous data 4025.3 Test voltages 4025.4 FCC requirements 4026 Normal Operation Test 4127 Input Test 4128 Output Measurement Test .4129 Power-Limited Circuits .4229.1 General .4229.2 Maximum voltage 4329.3 Maximum current .4629.4 VAmax(Not inherent
21、ly limited circuits only) 4630 Electrical Supervision Test .4631 Undervoltage Operation Test .4732 Overvoltage Operation Test 4733 Variable Ambient Test .4734 Humidity Test 4735 Electric Shock Current Test 4736 Leakage Current Tests for Cord-Connected Products .5237 Overload Test 5537.1 General .553
22、7.2 Separately energized circuits 5538 Endurance Test 5538.1 General .5538.2 Separately energized circuits 5539 Jarring Test 5640 Road Shock and Vibration Tests 5741 Dielectric Voltage-Withstand Test .5742 Temperature Test .5843 Abnormal Operation Test 6244 Electrical Transient Tests 6244.1 General
23、.62SEPTEMBER 1, 1999ANTITHEFT ALARMS AND DEVICES - UL 10374UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL44.2 Supply line transients .6244.3 Internally induced transients .6344.4 Input/output circuit transients 6345 AC Induction Test .6446 P
24、olymeric Materials Test .6547 Battery Replacement Test .6548 Drop Test 6549 Strain Relief Test .6649.1 Supply cord .6649.2 Field-wiring leads .6650 Ignition Through Bottom-Panel Openings Tests .6650.1 General .6650.2 Hot, flaming oil .6650.3 Molten PVC and copper .6751 Mechanical Strength Tests for
25、Enclosures .6752 Special Terminal Assemblies Tests .6852.1 General .6852.2 Disconnection and reconnection .6852.3 Mechanical secureness .6852.4 Flexing test 6852.5 Millivolt drop test .6852.6 Temperature test .6953 Attack Test .6954 Residential Security Container 6954.1 Locks .6954.2 Attack tests 69
26、MANUFACTURING AND PRODUCTION TESTS ALL HIGH-VOLTAGE PRODUCTS55 General 7056 Production Line Dielectric Voltage-Withstand Test 7057 Production Line Grounding Continuity Test for High-Voltage, Cord-Connected Products .71MARKINGS ALL PRODUCTS58 Details .7159 Marking Permanency Tests 73OUTDOOR USE EQUIP
27、MENTASSEMBLY60 General 7461 Construction .7461.1 General .7461.2 Corrosion protection 7462 Field-Wiring Connections 7663 Internal Wiring 7764 Components, Electrical Insulating Material .78SEPTEMBER 1, 1999 ANTITHEFT ALARMS AND DEVICES - UL 1037 4AUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER RE
28、PRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPERFORMANCE65 Rain Test 7866 Dust Test 8267 Variable Ambient Test .8268 Metallic Coating Thickness Test 8269 Corrosion Tests 8469.1 General .8469.2 Salt spray (fog) 8469.3 Moist hydrogen sulfide (H2S) air mixture 8469.4 Moist carbon dioxide (CO2)-s
29、ulfur dioxide (SO2)-air mixture .8470 Ultraviolet Light and Water Exposure Test .8571 Accelerated Aging Tests For Gaskets, Sealing Compounds, and Adhesives .85MARKINGS72 Details .87ACCESSORY EQUIPMENT73 General 8774 Construction .8775 Performance (Installation) Test .8876 Markings .88APPENDIX AStand
30、ards for ComponentsA1SEPTEMBER 1, 1999ANTITHEFT ALARMS AND DEVICES - UL 10374BUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSEPTEMBER 1, 1999 ANTITHEFT ALARMS AND DEVICES - UL 1037 5No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED
31、FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULThis page intentionally left blank.NOVEMBER 16, 2004ANTITHEFT ALARMS AND DEVICES - UL 10376UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requireme
32、nts apply to the construction, performance, and operation of equipment intended toprovide antitheft protection.1.2 An antitheft alarm is intended to give both audible and visible signals or only an audible signal if theftof protected property is attempted.1.3 An antitheft device is intended to prote
33、ct property by significantly limiting the mobility or portability ofthe property.1.4 A product that contains features, characteristics, components, materials, or systems new or differentfrom those covered by the requirements in this standard, and that involves a risk of fire, electric shock, orinjur
34、y to persons shall be evaluated using the appropriate additional component and end-productrequirements to determine that the level of safety as originally anticipated by the intent of this Standard ismaintained. A product whose features, characteristics, components, materials, or systems conflict wi
35、thspecific requirements or provisions of this Standard shall not be judged to comply with this Standard.Where appropriate, revision of requirements shall be proposed and adopted in conformance with themethods employed for development, revision, and implementation of this Standard.2 General2.1 Compon
36、ents2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply withthe requirements for that component. See Appendix A for a list of standards covering componentsgenerally used in the products covered by this standard.2.1.2 A component is not required to compl
37、y with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this standard, orb) Is superseded by a requirement in this standard.2.1.3 A component shall be used in accordance with its rating established for the i
38、ntended conditions ofuse.2.1.4 Specific components are incomplete in construction features or restricted in performancecapabilities. Such components are intended for use only under limited conditions, such as certaintemperatures not exceeding specified limits, and shall be used only under those spec
39、ific conditions.NOVEMBER 16, 2004 ANTITHEFT ALARMS AND DEVICES - UL 1037 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2.2 Units of measurement2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanator
40、y orapproximate information.2.2.2 Unless otherwise indicated, all voltage and current values mentioned in this standard areroot-mean-square (rms).2.3 Undated references2.3.1 Any undated reference to a code or standard appearing in the requirements of this standard shallbe interpreted as referring to
41、 the latest edition of that code or standard.2.4 Terminology2.4.1 The term product as used in this standard refers to all types of antitheft alarms and devices.3 Glossary3.1 For the purpose of this standard the following definitions apply.3.2 CIRCUITS, ELECTRICAL a) High-Voltage (Class 1) A circuit
42、involving a potential of not more than 600 volts and havingcircuit characteristics in excess of those of a low-voltage power-limited circuit.b) Low-Voltage A circuit involving a potential of not more than 30 volts alternating current(AC) rms, 42.4 volts peak or direct current (DC).c) Power Limited A
43、 circuit whose output is limited as specified in Power-Limited Circuits,Section 29.d) Class2Acircuit in which the voltage and power limitations are in accordance with therequirements of Table 29.1 for AC circuits and Table 29.2 for DC circuits.e) Class3Acircuit in which the voltage and power limitat
44、ions are in accordance with therequirements of Table 29.1 for AC circuits and Table 29.2 for DC circuits.Revised 3.2 effective February 24, 2001Table 3.1Power limitations for inherently limited power source (overcurrent protection not required)*Table 3.1 revised and relocated as Table 29.1 effective
45、 February 24, 2001*3.3 CORD-CONNECTED UNIT A unit intended for connection to the power source by means of asupply cord. Such a unit is intended to be moved for reasons of interchange or realignment of the unitsof a system.Table 3.2Power limitations for power sources not inherently limited (overcurre
46、nt protection required)*Table 3.2 revised and relocated as Table 29.2 effective February 24, 2001*NOVEMBER 16, 2004ANTITHEFT ALARMS AND DEVICES - UL 10378UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3.4 LINE VOLTAGE The voltage at any field
47、 connected source of supply, nominally 50 60 hertz(Hz), and either 115, 208, or 230 volts.3.5 NORMAL STANDBY CONDITION The ready-to-operate condition of the product existing prior toits being tripped or operated by theft attempt.NOVEMBER 16, 2004 ANTITHEFT ALARMS AND DEVICES - UL 1037 8AUL COPYRIGHT
48、ED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNOVEMBER 16, 2004ANTITHEFT ALARMS AND DEVICES - UL 10378BNo Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3.6 PRIMARY BATTERY A bat
49、tery that by construction is not intended to be recharged.3.7 RESIDENTIAL SECURITY CONTAINER A container intended to be used in a residence to providemoderate protection to items against burglary or theft.3.8 SAFETY CIRCUIT Any primary or secondary circuit that is relied upon to reduce the risk of fire,electric shock, or unintentional contact with moving parts that may cause injury to persons (for example,an interlock circuit).3.9 SECONDARY BATTERY A battery that by construction is intended to be rech