1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1097 Double Insulation Systems for Use in Electrical EquipmentUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIA
2、L NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Double Insulation Systems for Use in Electrical Equipment, UL 1097 Sixth Edition, Dated February 1, 2012 Summary of Topics This sixth edition is being issued to adopt UL 1097 for the rst t
3、ime as an ANS approved standard, with an ANSI approval date of February 1, 2012. The requirements are substantially in accordance with Proposal(s) on this subject dated December 12, 2011. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
4、 in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any
5、purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has
6、 been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and ag
7、ainst any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for t
8、hose paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are pre
9、ceded by a SUPERSEDED REQUIREMENTS notice. FEBRUARY 1, 2012 UL 1097 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 1, 2012 UL 1097 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRI
10、BUTION WITHOUT PERMISSION FROM UL FEBRUARY 1, 2012 1 UL 1097 Double Insulation Systems for Use in Electrical Equipment First Edition November, 1978 Second Edition April, 1983 Third Edition June, 1993 Fourth Edition September, 1997 Fifth Edition July, 2004 Sixth Edition February 1, 2012 The most rece
11、nt designation of ANSI/UL 1097 as an American National Standard (ANSI) occurred on February 1, 2012. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be subm
12、itted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Stand
13、ards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2012 UNDERWRITERS LABORATORIES INC. ANSI/UL 1097-2012UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBR
14、UARY 1, 2012 DOUBLE INSULATION SYSTEMS FOR USE IN ELECTRICAL EQUIPMENT - UL 1097 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 General 4 2.1 Units of measurement .4 2.2 Undated refer
15、ences .4 3 Glossary .4 CONSTRUCTION 4 General 6 5 Reinforced Insulation 7 5.1 General .7 5.2 Brush caps and brush holders .7 5.3 Commutator and end turns of the armature winding 8 5.4 Switches 9 5.5 Power-supply cord .10 5.6 Internal wiring .10 5.7 Other locations 11 6 Flexible Cord 11 7 Strain Reli
16、ef .11 8 Bushings 11 9 Capacitors 12 10 Transformers .12 11 Spacings 12 12 Internal Wiring 13 PERFORMANCE 13 Leakage Current Test .14 14 Dielectric Voltage-Withstand Tests 18 15 Insulation Resistance Test .18 16 Resistance to Impact Tests 19 17 Overload Tests on Isolating Transformers .20 18 Overloa
17、d Test on Motors 22 19 Abnormal Operation Test 23 20 Investigation of Armature Employing Reinforced Insulation Test 23 21 Moisture Resistance Test 24 MANUFACTURING AND PRODUCTION TESTS 22 Production-Line Dielectric Voltage-Withstand Test 24 MARKINGS 23 General 25 FEBRUARY 1, 2012 DOUBLE INSULATION S
18、YSTEMS FOR USE IN ELECTRICAL EQUIPMENT - UL 1097 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover electrically operated equipment marked Double Insulation or Double Insulated to be used in ac
19、cordance with the National Electrical Code, ANSI/NFPA 70. 1.2 Equipment marked Double Insulation or Double Insulated shall comply with the applicable requirements in this standard and the standard covering the particular type of equipment the end-product standard. In cases where the end-product stan
20、dard contains requirements for double insulation, that standard takes precedence. 2 General 2.1 Units of measurement 2.1.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 2.2 Undated references 2.2.1 Any undated reference to a
21、code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 3 Glossary 3.1 For the purpose of this standard the following denitions apply. 3.2 ACCESSIBLE PART or SURFACE A part or surface subject to contact by pers
22、ons under any condition of operation or user function. In a determination of whether a live or dead part or surface is accessible to such contact, the criteria specied in the product standard are to be applied. 3.3 BASIC INSULATION (formerly FUNCTIONAL INSULATION) The insulation applied to live part
23、s to provide basic protection against electric shock. Basic insulation does not necessarily include insulation used exclusively for functional purposes. 3.4 DEAD METAL PART A metal or other electrically conductive part, accessible or inaccessible, that is not conductively connected to a live part. 3
24、.5 DOUBLE INSULATION An insulation system comprised of basic (formerly functional) insulation and supplementary insulation, with the two insulations physically separated and arranged so that they are not simultaneously subjected to the same deteriorating inuences (temperature, contaminants, and the
25、like) to the same degree. See Figure 3.1. This is generated text for gtxt. FEBRUARY 1, 2012 DOUBLE INSULATION SYSTEMS FOR USE IN ELECTRICAL EQUIPMENT - UL 1097 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Figure 3.1 Examples illustrating
26、 3.5 FEBRUARY 1, 2012 DOUBLE INSULATION SYSTEMS FOR USE IN ELECTRICAL EQUIPMENT - UL 1097 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3.6 LIVE PART A part that is conductively connected either to the power-supply circuit, or a secondary
27、 circuit that operates at more than 42.4 V peak with reference to ground or accessible metal, and in which the available current measured through a 1500-ohm resistor shunted with a 0.15-F capacitor connected from the part to ground or to any other accessible part exceeds 0.25 mA. 3.7 REINFORCED INSU
28、LATION An improved basic (formerly functional) insulation with such mechanical and electrical qualities that it, in itself, provides the same degree of protection against electric shock as double insulation. It may consist of one or more layers of insulating material. Its acceptance in place of doub
29、le insulation is described in 4.1 and Reinforced Insulation, Section 5. 3.8 SUPPLEMENTARY (PROTECTING) INSULATION An independent insulation provided in addition to the basic (formerly functional) insulation to protect against electric shock in case of mechanical rupture or electrical breakdown of th
30、e basic insulation. An enclosure of insulating material may form a part or the whole of the supplementary insulation. CONSTRUCTION 4 General 4.1 The equipment shall be constructed so that double insulation is interposed between all live parts and each of the following: a) All accessible surfaces of
31、the equipment; b) All inaccessible dead parts and surfaces that are conductively connected to accessible dead parts or surfaces or both. Exception No. 1: A construction that provides increased through-air and over-surface spacings between live parts and accessible dead parts and surfaces specied in
32、the end-product standard (refer to Table 11.1) is acceptable in place of double insulation. This construction may be used only where it is impractical to provide double insulation. Exception No. 2: A construction using Reinforced Insulation, Section 5, is acceptable in place of double insulation. Th
33、is construction may be used only where it is impractical to provide double insulation. 4.2 The thickness and the resistance to deterioration with aging of insulation employed as supplementary insulation shall not be less than that required for the same material employed as basic insulation. A greate
34、r thickness of supplementary insulation is required if severe environmental or use conditions are likely. 4.3 The insulation qualities and resistance to deterioration with aging of materials employed as reinforced insulation shall not be less than the combination of basic and supplementary insulatio
35、n. 4.4 The equipment shall be constructed so that the added protection provided by the supplementary or reinforced insulation is not reduced by the normal use and reasonable abuse (see Resistance to Impact Tests, Section 16, and Abnormal Operation Test, Section 19) to which the equipment is likely t
36、o be subjected. FEBRUARY 1, 2012 DOUBLE INSULATION SYSTEMS FOR USE IN ELECTRICAL EQUIPMENT - UL 1097 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 4.5 The equipment shall be constructed so that the following parts are not accessible: a) A
37、 live part; b) A dead part that is insulated from live parts by basic insulation only, unless it is Reinforced Insulation, Section 5; c) Basic insulation itself, unless it is Reinforced Insulation, Section 5. 4.6 The equipment shall be constructed so that all parts straps, screws, nuts, washers, spr
38、ings, and the like are secured so that they are not likely to become loosened or displaced if such loosening or displacement reduces the spacings to values below those specied in Table 11.1. 4.7 Parts secured by two independent fastenings or by means of screws or nuts provided with lock washers are
39、to be regarded as not likely to become loose, provided that these fastening means are not required to be removed during routine servicing. Exception: Where loosening or displacement of the part causes malfunctioning of the equipment and does not result in an accessible live part. 4.8 Leakage, ruptur
40、e, or overlling of a reservoir, pipe, tube, or the like for storing or conducting water or other uid associated with the equipment shall not render either basic, reinforced, or supplementary insulation ineffective or result in deterioration of the insulation. 5 Reinforced Insulation 5.1 General 5.1.
41、1 Reinforced insulation can be accepted in place of double insulation in the locations described in 5.2.1.1 5.7.1. 5.2 Brush caps and brush holders 5.2.1 General 5.2.1.1 Reinforced insulation can be accepted in an accessible brush cap or brush holder if the construction complies with each of the fol
42、lowing: a) The brush cap or brush holder shall be recessed so that, when it is mounted normally, its top is inside the plane of the opening in the surrounding portion of the enclosure of the equipment. b) The brush cap or brush holder shall be entirely of insulating material. c) The brush cap or bru
43、sh holder shall acceptably withstand the impact test described in 16.2. FEBRUARY 1, 2012 DOUBLE INSULATION SYSTEMS FOR USE IN ELECTRICAL EQUIPMENT - UL 1097 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5.2.2 Brush holders in enclosures o
44、f insulating material 5.2.2.1 Reinforced insulation is acceptable in place of double insulation at a brush holder assembly that is supported in the insulating-material housing of the equipment. The total insulation thickness shall not be less than 3/16 inch (4.8 mm) provided that any path between pa
45、rts of the enclosure is broken by barriers or the like so that there is no direct path from the outside to live parts of the brush holder assembly. 5.2.3 Brush holders in enclosures of conductive material 5.2.3.1 Reinforced insulation is acceptable in place of double insulation at a brush holder ass
46、embly that has its own enclosure of insulating material if the construction complies with both of the following: a) All live parts of the brush holder assembly shall be enclosed in the enclosure of insulating material. Exception: The wiring terminals and the brush itself need not comply with this re
47、quirement. b) The enclosure of the brush holder assembly shall be separated from accessible dead metal parts by any one or more of the following constructions: 1) Mica not thinner than 0.005 inch (0.13 mm); 2) Other inorganic insulation having electrical properties at least equivalent to those of mi
48、ca; 3) Acceptable organic insulating material not less than 1/16 inch (1.6 mm) thick. 5.3 Commutator and end turns of the armature winding 5.3.1 Reinforced insulation is acceptable between the commutator segments and the shaft, the end turns and the shaft, and in both locations if the insulation con
49、sists of one or more of the following: a) Sheet mica that is not less than 0.005 inch (0.13 mm) thick. b) Other inorganic insulation having electrical properties at least equivalent to those of mica. If such insulation is used under the commutator segments, the thickness of the insulation shall not be less than 0.080 inch (2.0 mm). If such insulation is used under the end turns, the thickness of the insulation shall not be less than 0.040 inch (1.02 mm) or the length of the air gap,