1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 310 Electrical Quick-Connect TerminalsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FUR
2、THER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Electrical Quick-Connect Terminals, UL 310 Ninth Edition, Dated Summary of Topics This Ninth Edition of the Standard for Safety for Electrical Quick-Connect Terminals, UL 310, includes the following major changes
3、: Crimp Pull Out Test Method; Clarication of Construction; Inclusion of 24 - 26 AWG Wire Sizes; Deletion of E2 Dimension for Positioning of Detent; Use of Other Platings and Materials; Temperature and Current Cycling Test for Multiple Conductors; and additional miscellaneous changes. The new require
4、ments are substantially in accordance with Proposal(s) on this subject dated January 24, 2014 and June 13, 2014. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording,
5、or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequ
6、ential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liab
7、ility for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including r
8、easonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Stan
9、dard having future effective dates as indicated in the preface. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. OCTOBER 17, 2014 UL 310 tr1UL COPYRIGHTED MATERIAL NOT AU
10、THORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 17, 2014 UL 310 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CSA Group CSA-C22.2 No. 15314 Third Edition Underwriters Laboratorie
11、s Inc. UL 310 Ninth Edition Electrical Quick-Connect Terminals October 17, 2014 ANSI/UL 310-2014UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard is issued jointly by the Canadian Standards Association (
12、operating as “CSA Group”) and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to CSA Group or UL at any time. Revisions to this standard will be made only after processing according to the standards development procedures of CSA G
13、roup and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ISBN 978-1-771394536 2014 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior pe
14、rmission of the publisher. This Standard is subject to periodic review, and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to inquirescsagroup.org and include “Proposal for change” in the subject l
15、ine: Standard designation (number); relevant clause, table, and/or gure number; wording of the proposed change; and rationale for the change. To purchase CSA Group Standards and related publications, visit CSA Groups Online Store at www.ShopCSA.ca or call toll-free 1-800-463-6727 or 416-747-4044. Co
16、pyright 2014 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive
17、property of UL. This ANSI/UL Standard for Safety consists of the Ninth Edition. The most recent designation of ANSI/UL 310 as an American National Standard (ANSI) occurred on October 15, 2014. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back
18、), or the Preface. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. To purchase UL Standards, visit Comm 2000 at http:/m
19、- or call toll-free 1-888-853-3503.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface .4 1 Scope .6 2 Denitions 6 3 Units of measurement .7 4 Normative references 7 5 Construction 8 5.1 General .8 5.2 Materials 8 5.3 Dimensions
20、 9 5.4 Insulation .10 6 Tests .10 6.1 General 10 6.2 Preparation of specimens 11 6.3 Crimp pull-out test .12 6.4 Insertion-withdrawal test 12 6.5 Temperature and current cycling tests .13 6.6 Dielectric withstand tests .14 6.7 Secureness of insulation test .15 7 Markings 16 8 Installation instructio
21、ns .17 18 25 ANNEX A (Informative) MILLIVOLT DROP TEST A1 General .31 A2 Millivolt drop measurement 31 OCTOBER 17, 2014 CSA-C22.2 NO. 15314 UL 310 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Preface This is the harmonized CSA Group and
22、UL standard for Electrical Quick-Connect Terminals. It is the Third edition of CSA-C22.2 No. 153 and the Ninth edition of UL 310. This edition of CSA C22.2 No. 153 supersedes the previous edition published in 2009. This edition of UL 310 supersedes the previous edition published May 27, 2009. This h
23、armonized standard was prepared by the CSA Group and Underwriters Laboratories Inc. (UL). The efforts and support of the CANENA Technical Harmonization Subcommittee 99, Electrical Quick-Connect Terminals, are gratefully acknowledged. This Standard is considered suitable for use for conformity assess
24、ment within the stated scope of the Standard. This Standard was reviewed by the CSA Integrated Committee on Electrical Connectors, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been for
25、mally approved by the CSA Technical Committee. This Standard was reviewed by ULs Standards Technical Panel (STP) for Electrical Quick-Connect Terminals, STP 310. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Where reference is m
26、ade to a specic number of samples to be tested, the specied number is considered a minimum quantity. Note: Although the intended primary application of this standard is stated in its scope, it is important to note that it remains the responsibility of the users of the standard to judge its suitabili
27、ty for their particular purpose. Level of harmonization This standard uses the IEC format but is not based on, nor is it considered equivalent to, an IEC standard. This standard is published as an identical standard for CSA Group and UL. An identical standard is a standard that is exactly the same i
28、n technical content except for national differences resulting from conicts in codes and governmental regulations. Presentation is word for word except for editorial changes. Reasons for differences from IEC This standard provides requirements for electrical quick-connect terminals for use in accorda
29、nce with the electrical installation codes of Canada and the United States. At present there is no IEC Standard for electrical quick-connect terminals for use in accordance with these codes. Therefore, this standard does not employ any IEC Standard for base requirements. OCTOBER 17, 2014 CSA-C22.2 N
30、O. 15314 UL 310 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Interpretations The interpretation by the standards development organization of an identical or equivalent standard is based on the literal text to determine compliance with th
31、e standard in accordance with the procedural rules of the standards development organization. If more than one interpretation of the literal text has been identied, a revision is to be proposed as soon as possible to each of the standards development organizations to more accurately reect the intent
32、. CSA Group effective date The effective date for CSA Group will be announced through a CSA Group certication notice. UL effective date As of October 17, 2014 all products Listed or Recognized by UL must comply with the requirements in this standard. A UL effective date is one established by Underwr
33、iters Laboratories Inc. and is not part of the ANSI approved standard. OCTOBER 17, 2014 CSA-C22.2 NO. 15314 UL 310 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 1 Scope 1.1 This standard applies to quick-connect terminals, both connectors
34、 and tabs, having nominal widths of 2.8, 3.2, 4.8, 5.2, and 6.3 mm (0.110, 0.125, 0.187, 0.205, and 0.250 in). They are intended for internal wiring connections in electrical equipment and for the eld termination of conductors to electrical equipment in accordance with Part I of the Canadian Electri
35、cal Code, C22.1, in Canada, and the National Electrical Code, NFPA 70, in the United States of America. 1.2 These requirements apply to quick-connect terminals intended for use with one or two 26 10 AWG (0.13 - 5.3 mm 2 ) copper conductors. 1.3 These requirements do not apply to terminals for use wi
36、th aluminum conductors. 1.4 These requirements do not apply to multi-pole devices. Multi-pole devices are covered by UL 1977 and CSA C22.2 No. 182.3. 1.5 In Canada, general requirements applicable to this standard are given in CAN/CSA-C22.2 No. 0. 2 Denitions For the purpose of this standard the fol
37、lowing denitions apply. 2.1 BURR An extraneous protrusion in the stock, not considered an integral functional part of the connector or tab. 2.2 CONNECTOR (female connector) That portion of a quick-connect termination which is pushed onto the male tab. 2.3 C26000 ALLOY A copper-zinc alloy consisting
38、of approximately 70 percent copper and 30 percent zinc (cartridge brass) as specied by the Copper Development Associations Copper Development Alloy (CDA) Standards Handbook, Wrought Copper and Copper Alloy Mill Products, Part 2 Alloy Data. 2.4 DETENT A dimple (depression) or hole in the male tab tha
39、t engages a raised portion on the female connector, thus providing a latch for the mating parts. 2.5 PRODUCTION TAB (male tab) That portion of a quick-connect termination which receives the female connector. 2.6 QUICK-CONNECT TERMINATION An electrical connection consisting of a male tab and female c
40、onnector that can be readily inserted or withdrawn without the use of a tool. 2.7 REFERENCE POINT A specially marked point on a connector or tab that is used when making electrical test measurements. 2.8 TERMINAL An electrical connecting device; may be either a female connector or male tab. 2.9 TEST
41、 TAB (male test tab) A male tab, manufactured to close tolerances and with specic materials, used for the purpose of conducting tests with production female connectors. OCTOBER 17, 2014 CSA-C22.2 NO. 15314 UL 310 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOU
42、T PERMISSION FROM UL 3 Units of measurement 3.1 The values given in SI (metric) units as well as AWG conductor sizes shall be normative. Any other values given are for information purpose only. 3.2 Unless otherwise stated, all alternating-current (ac) electrical measurements are in root-mean-square
43、(rms) units. 4 Normative references 4.1 Where reference is made to any Standards, such reference shall be considered to refer to the latest editions and revisions thereto available at the time of printing, unless otherwise specied. CSA Group C22.1-12 Canadian Electrical Code, Part I, (CE Code) CAN/C
44、SA-C22.2 No. 0-10 General Requirements Canadian Electrical Code, Part II CAN/CSA-C22.2 No. 0.17-00 (R2013) Evaluation of Properties of Polymeric Materials CSA-C22.2 No. 182.3-M1987 (R2009) Special Use Attachment Plugs, Receptacles, and Connectors UL (Underwriters Laboratories Inc.) UL 94 Standard fo
45、r Tests for Flammability of Plastic Materials for Parts in Devices and Appliances UL 1977 Standard for Component Connectors for Use in Data, Signal, Control and Power Applications CDA (Copper Development Association) CDA Standards Handbook Wrought Copper and Copper Alloy Mill Products, Part 2 Alloy
46、Data IEC (International Electrotechnical Commission) IEC 61210 Ed. 2.0 Connecting Devices - Flat Quick-Connect Terminations for Electrical Copper Conductors - Safety Requirements NFPA (National Fire Protection Association) ANSI/NFPA 70-2014 National Electrical Code (NEC) OCTOBER 17, 2014 CSA-C22.2 N
47、O. 15314 UL 310 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5 Construction 5.1 General 5.1.1 Terminals shall be designed to provide a reliable electrical connection between wires and between wires and components in electrical equipment,
48、 when used in the intended manner. Additional requirements concerning certain features such as insulation added at the time of assembly in equipment, spacings between terminals of opposite polarity and between terminals and non-current-carrying metal parts, and the support of wires adjacent to the t
49、erminals shall be the subject of consideration by the standard covering the specic equipment involved. 5.1.2 A connector shall comply with Clause 5.2, the dimensional requirements of Clause 5.3.1, and the applicable test requirements of Clause 6, when the connector is tested in conjunction with a test tab complying to Clause 5.2.2 and Clause 5.3.3. 5.1.3 A production tab shall comply with Clause 5.2, the dimensional requirements
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1