1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): RTRTStandard Number: UL 498Standard Title: Standard for Attachment Plugs and ReceptaclesEdition Date: March 30, 2012Edition Number: 15Section / Paragraph Reference: Tables 115.2 and 183.2Subject: Hors
3、epower Ratings for ANSI/NEMA configurations L25-30R and L26-30RDECISION:Modified Table 115.2 adding additional values for L25-30 and L26-30 configurationsTable 115.2Test current (locked rotor amperes) for horsepower rated NEMA configuration receptaclesNEMA configuration AC HP ratingaLRA (amperes) AC
4、 test voltageL25-30R 2 L-Lb72 25079.2 208L26-30R 7.5 84 415127 240Modified Table 183.2 adding additional values for L25-30 and L26-30 configurationsTable 183.2Horsepower ratings for NEMA configurationsNEMA configuration AC HP ratingaL25-30R 2 L-LbL26-30R 7.5RATIONALE FOR DECISION:This CRD identifies
5、 the Horsepower rating for the newly created ANS/NEMA receptacle configurationsL25-30R and L26-30R. The horsepower test current (locked rotor amperes) is based upon UL 508 Table45.2, full-load motor running currents in amperes for single-phase and Table 45.4 for locked-rotor motorcircuits for 3-phas
6、e ratings. For full-load motor running current, single phase (UL 508, Table 45.2) lockedrotor amperage is 6 times fullload current.Copyright 2016 UL LLCUL LLC, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Dec
7、isions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of UL LLC. in practically applying therequirements of the standard. They do not represent formal interpretations of the standard underAmerican National Standards Institute (AN
8、SI) processes. UL LLC shall not be responsible to anyone forthe use of or reliance upon Certification Requirement Decisions by anyone. UL LLC shall not incur anyUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULobligation or liability for damage
9、s, including consequential damages, arising out of or in connection withthe use or reliance upon Certification Requirement Decisions. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 498 -2-