1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-6Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Automatic Electrical Pressure Sensing Controls Inc
2、luding MechanicalRequirementsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-6Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Automatic Electrical
3、Pressure Sensing Controls Including Mechanical RequirementsEdition: 2Edition Date: October 18, 2013These revisions are being issued to reflect the established effective date for UL60730-2-6.AS OF OCTOBER 19, 2018, THE FIRST EDITION OF UL 60730-2-6 AND THE TWELFTHEDITION OF UL 873 WILL BE WITHDRAWN A
4、ND WILL BE REPLACED BY THISSTANDARD.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any mean
5、s, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no e
6、vent will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been
7、advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and ag
8、ainst any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2014 Underwriters Laboratories Inc.JUNE 10, 2014NATIONAL D
9、IFFERENCES FOR UL UL 60730-2-62UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based s
10、tandards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhi
11、ch would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - T
12、hese are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements
13、.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, su
14、bclause, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is a
15、n altering of the existing base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.JUNE 10, 2014 NATIONAL DIFFERENCES FOR UL UL 60730-2-6 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FUR
16、THER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1.1DV DE Modification of 1.1 of the part 2 by adding the following:Conversions: -60 kPa to -8,71 psi and 4,2 MPa to 609,58 psi.1.1.1DV DE Modification to clarify 1.1.1 of the part 2:In IEC terminology, safety is defined a
17、s an acceptable level of risk. This is consistent withthe intention of UL requirements to reduce the risk of fire, electric shock or injury topersons.4.3.1.101DV D2 Modification of 4.3.1.101 of the part 2 by adding the following note:NOTE In the U.S.A., the number of cycles specified in Annex AA app
18、ly for independently mounted,integrated and incorporated pressure controls.Table 7.2DV D2 Replacement of Table 7.2 of the part 2:Table 7.2DVRequirement Information Clause or subclause MethodModification:Replace the following items by:6 Purpose of control 2.2.101 to 2.2.103,4.3.5, 6.3D26 Number of cy
19、cles of ACTUATION (M) for eachMANUAL ACTION101A)6.10, Annex AA X27 Number of automatic cycles (A) for eachAUTOMATIC ACTION101A)6.11, Annex AA X34 Not applicable37 See additional notes102A), 103A)4, 15, 17 X44 Not applicable48 Operating pressure104A)2.3.11 D(or pressures) 15Additional items: 18101 PR
20、ESSURE MEDIUM 2.3.101 X102 OPERATING DIFFERENTIAL 2.3.26 D103 MAXIMUM WORKING PRESSURE 2.3.29 D104A A low voltage (0 30 volt) cut-out to be wiredwith NEC Class 1 wiring methodsD105A Date code of manufacturing for INDEPENDENTLYMOUNTED CONTROLS105A)CAddition to Note 4:For pressure sensing controls, li
21、mits of activating quantity are specified either in the applicable household appliancepart 2, by the appliance manufacturer or as declared by the pressure sensing control manufacturer (see 17.7 and 17.8).Additional notes:101A)The minimum number of cycles for independently mounted, integrated and INC
22、ORPORATED CONTROLS are indicated inAnnex AA.JUNE 10, 2014NATIONAL DIFFERENCES FOR UL UL 60730-2-64Table 7.2DV Continued on Next PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 7.2DV ContinuedRequirement Information Clause or subclaus
23、e Method102A)For Type 2 controls, the required deviations and DRIFT tolerances are indicated in Table AA.101DV.103A)Deviation and DRIFT applies to a SPDT cutout terminal which is de-energized on pressure rise.105A)The date code shall be the date or other dating period of manufacture not exceeding an
24、y three consecutivemonths. The date of manufacture may be abbreviated; or may be in a nationally accepted conventional code or in acode affirmed by the manufacturer, provided that the code:a) Does not repeat in less than 20 years, andb) Does not require reference to the product records of the manufa
25、cturer to determine when theproduct was manufactured.11.6.101DV D2 Addition to the part 2:If the function or calibration of the control is affected by being placed out of level, thecontrol shall be provided with a leveling indicator such as a bubble, pendulum, or ahorizontal or vertical line. When a
26、ttached as intended, the control shall resist a torque of11,3 Nm (8,5 lbfft) without moving.11.6.102DV D2 Addition to the part 2:If a control requires a mounting bracket to conform to this standard, the bracket shall befurnished with the control. The bracket shall be marked with a part number and it
27、s useshall be indicated on the control. This marking may be placed inside the control COVER.11.11.103DV.1 DE Modification of 11.11.103 of the part 2 by adding the following noteafter the first paragraph:NOTE Unsafe leakage of a hazardous fluid is the leakage of a fluid due to failure of any part of
28、thecontrol that would result in a risk of injury to persons.11.11.103DV.2 DE Modification of 11.11.103 of the part 2 by adding the following noteafter the third paragraph:NOTE These requirements do not apply to a seal, diaphragm or gasket that is resistant to the actionof the sensed fluid.11.11.104D
29、V D2 Addition of 11.11.104DV.1 11.11.104DV.10 to the part 2:11.11.104DV.1 After being subjected to the conditions described in 11.11.104DV.2 11.11.104DV.4, a brass part containing more than 15 percent zinc shall show no evidenceof cracking when examined using 25X magnification.11.11.104DV.2 Each tes
30、t sample is to be subjected to the physical stresses normallyimposed on or within a part as the result of assembly with other components. Suchstresses are to be applied to the sample prior to and maintained during the test. Sampleswith threads, intended to be used for installing the product in the f
31、ield, are to have thethreads engaged and tightened to the torque specified in Table 11.11.104DV.2.1. Teflontape or pipe compound are not to be used on the threads.JUNE 10, 2014 NATIONAL DIFFERENCES FOR UL UL 60730-2-6 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WI
32、THOUT PERMISSION FROM ULTable 11.11.104DV.2.1 D2 Addition to the part 2:Table 11.11.104DV.2.1 Torque requirements for threaded connectionsNominal thread size, inches Torque Nm (lbft)1/8 27 (20)1/4 34 (25)3/8 50,8 (37,5)1/2 67,8 (50)3/4 101,7 (75)1 135,6 (100)1-1/4 163,8 (121)1-1/2 175,1 (129)2 186,4
33、 (137)2-1/2 197,7 (146)3 203,4 (150)11.11.104DV.3 Three samples are to be degreased and then continuously exposed in a setposition for 10 days to a moist ammonia-air mixture maintained in a glass chamberapproximately 305 by 305 by 305 mm (12 by 12 by 12 inch) having a glass COVER.11.11.104DV.4 Appro
34、ximately 600 mL of aqueous ammonia having a specific gravity of0,94 is to be maintained at the bottom of the glass chamber below the samples. Thesamples are to be positioned 38,1 mm (1-1/2 inch) above the aqueous ammonia solutionand supported by an inert tray. The moist ammonia-air mixture in the ch
35、amber is to bemaintained at atmospheric pressure and at a temperature of 34 2C (91 4F).11.11.104DV.5 An elastomeric part shall be in accordance with the requirements for theAccelerated Air Oven Aging Test in the Standard for Gaskets and Seals, UL 157.11.11.104DV.6 An elastomeric part intended to be
36、in contact with LP-Gas, manufacturedand natural gases, fuel oils and kerosene or gasoline shall be in accordance with therequirements for the Immersion Test in the Standard for Gaskets and Seals, UL 157.11.11.104DV.7 A cut-out or limiter incorporating a transformer, relay, or the like shall besuppli
37、ed by a one-side grounded system with a voltage rating not exceeding 120 voltsnominal. A switch or protective device shall be connected in the ungrounded supplyconductor circuit.11.11.104DV.8 A mercury switch shall be enclosed. Wire leads shall be as short aspossible and terminate at eyelets or the
38、equivalent, or in soldered connections at terminalplates on the supporting box or shall be fastened so that no strain is placed on themechanism.11.11.104DV.9 An INDEPENDENTLY MOUNTED CONTROL with manual reset shall be resettable fromthe exterior of the enclosure.JUNE 10, 2014NATIONAL DIFFERENCES FOR
39、 UL UL 60730-2-66UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL11.11.104DV.10 Connections for piping shall be threaded in accordance with the Standardfor General Purpose (Inch) Pipe Threads, ANSI/ASME B1.20.1-1983.11.11.105DV DE Modification
40、 of 11.11.105 of the part 2 by adding the following:External fluid leakage shall be limited to the levels specified in 18.101.11.11.106DV DE Modification of 11.11.106 of the part 2:Replace, .pressure, following the endurance test, and the control conforms to one of thefollowing: with . pressure, fol
41、lowing the endurance test. If leakage occurs, the controlshall conform to one of the following:15.1.101DV D2 Modification of 15.1.101 of the part 2 by adding the following:Refer to Table AA.101DV in Annex AA for maximum allowable variations of MANUFACTURINGDEVIATION and DRIFT.15.4DV D2 Modification
42、of 15.4 of the part 2 by adding:For Type 2 pressure SENSING CONTROLS, see Table AA.101DV in Annex AA.17.2.3.1DV D2 Modification to 17.2.3.1 of the UL part 1 by adding the following:208 V for controls rated at any voltage between 200 to 208 volts.17.16.102DV DE Modification of 17.16.102 of the part 2
43、:17.16.102DV.1 For 17.7 and 17.8, revise by the manufacturer in 7.2. to by themanufacturer in accordance with Table 7.2.17.16.102DV.2 For 17.9, delete as specified in 17.16.102.17.16.102DV.3 For the first paragraph beginning 17.10 to 17.13, replace limit controlswith limiters.17.16.102DV.4 For the s
44、econd paragraph beginning 17.10 to 17.13 replace limit controlwith limiter.17.16.103DV DE Modification of 17.16.103 of the part 2:For 17.7 and 17.8, replace 7.2 with accordance with Table 7.2.18.101DV.1 D2 Modification of 18.101 of the part 2 by adding the following note to item(a):NOTE In the U.S.,
45、 the In the countries. is not applicable.18.101DV.2 D2 Modification of 18.101 of the part 2 by adding the following note to item(b):NOTE In the U.S., the In the countries. is not applicable.JUNE 10, 2014 NATIONAL DIFFERENCES FOR UL UL 60730-2-6 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REP
46、RODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL18.101DV.3 D2 Modification of 18.101 of the part 2:Delete under consideration.18.102.2DV DE Modification of 18.102.2 of the part 2 by adding the following note:NOTE This requirement applies only to pressure SENSING CONTROLS rated 2 000 kPa or more.1
47、8.102.3DV DE Modification of 18.102.3 of the part 2 by adding the following note:NOTE This test does not apply to refrigeration limiters or cutouts.H.26.11DV DE Modification of H.26.11 of the part 2 by adding the following note:NOTE In the United States this applies.Table AA.1DV D2 Replacement of AA
48、.1 of the part 2:Table AA.1DV Number of cycles for INDEPENDENTLY MOUNTED CONTROLSTypeAUTOMATIC ACTION MANUAL ACTIONwith load no load with load no loadSelf-resetting cut-out 100 000 Non-self-resettingcut-out1 000a)5 000 1 000a)5 000Self-resetting limiterc)6 000b)Non-self-resettinglimiter6 000 6 000 P
49、ressure operatingc)6 000 Manual 6 000 In the U.S.A., the number of cycles specified apply for independently mounted, integrated and incorporated pressurecontrols.a)Break only.b)100 000 for gas appliances and furnace applications.c)30 000 cycles for refrigeration applications.Table AA.101DV D2 Addition to the part 2:JUNE 10, 2014NATIONAL DIFFERENCES FOR UL UL 60730-2-68UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable AA.101DV