1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 609 Local Burglar Alarm Units and SystemsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR
2、FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Local Burglar Alarm Units and Systems, UL 609 Eleventh Edition, Dated August 28, 1996 Summary of Topics The revisions were issued to incorporate the revision to minimum spacing requirements. The revised requir
3、ements are substantially in accordance with Proposal(s) on this subject dated October 7, 2011. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin
4、and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechani
5、cal photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any
6、 special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damag
7、e. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, cl
8、aim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/
9、or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. The
10、 following table lists the future effective dates with the corresponding reference. MARCH 20, 2015 UL 609 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Future Effective Date Reference March 20, 2018 Table 23.1 MARCH 20, 2015 UL 609 tr2U
11、L COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 28, 1996 (Title Page Reprinted: March 20, 2015) 1 UL 609 Standard for Local Burglar Alarm Units and Systems Previous unnumbered editions of standards covering this material have been publ
12、ished prior to 1928. The standards were titled Local Mercantile Burglar Alarm Systems and Local Burglar Alarm Systems for Bank Vaults and Safes. The rst through fourth editions were titled Local Burglar Alarm System and numbered both UL 609 and UL 610. First Edition April, 1942 Second Edition Novemb
13、er, 1947 Third Edition November, 1950 Fourth Edition October, 1959 Fifth Edition May, 1963 Sixth Edition May, 1971 Seventh Edition January, 1972 Eighth Edition March, 1978 Ninth Edition June, 1982 Tenth Edition November, 1990 Eleventh Edition August 28, 1996 This ANSI/UL Standard for Safety consists
14、 of the Eleventh Edition including revisions through March 20, 2015. The most recent designation of ANSI/UL 609 as an American National Standard (ANSI) occurred on March 20, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date informati
15、on. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed n
16、or electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 609-2015UL COPYRIGHTED MATERIAL NOT AUTHO
17、RIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 10, 2010 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .
18、7 2 General 8 2.1 Components .8 2.2 Units of measurement .8 2.3 Undated references .8 2.4 Terminology .8 3 Glossary .9 4 Installation and Operating Instructions 11 4A Installation and Operating Instructions Physical Media 12 5 Electric Shock 12A CONSTRUCTION ASSEMBLY 6 General .12A 6.1 Product assem
19、bly 12A 6.2 Electrical protection 13 7 Protection of Service Personnel .16 8 Enclosures 16 8.1 General 16 8.2 Doors and covers .17 8.3 Enclosure openings 17 8.4 Screens and expanded metal .20 8.5 Cast metal 20 8.6 Sheet metal .20A 8.7 Product enclosure mounting 23 8.8 Polymeric materials 23 9 Corros
20、ion Protection .24 FIELD WIRING CONNECTIONS 10 General 24 11 Cord Connected Products .24 12 Permanently Connected Products .25 12.1 General .25 12.2 Field-wiring terminals .26 12.3 Field wiring leads .28 12.4 Polarity identication 28 13 Grounding .29 13.1 General .29 13.2 Cord Connected Appliances .
21、29 SEPTEMBER 10, 2010 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTERNAL WIRING 14 General 30 15 Wiring Methods .31 16 Separation of Circuits .32 17 Bonding for Grounding 32 COMPONENTS, E
22、LECTRICAL 18 General 35 18.1 Mounting of components 35 18.2 Insulating materials .36 18.3 Fuseholders .37 18.4 Current-carrying parts .37 18.5 Power-on indicator .37 19 Overcurrent protection .37 20 Semiconductors 38 21 Switches .38 22 Transformers and Coils 38 SPACINGS 23 General 38 24 Components .
23、41 PERFORMANCE ALL UNITS 25 General 41 25.1 Test units and data .41 25.2 Test samples and miscellaneous data 41 25.3 Test voltages 41 25.4 FCC requirements 41 26 Normal Operation Test 42 27 Current Protection Test 42 28 Input Test 42 29 Output Measurement Test .43 30 Electrical Supervision Test .43
24、31 Undervoltage Operation Test .44 32 Overvoltage Operation Test 44 33 Variable Ambient Test .44 34 Humidity Test 44 35 Leakage Current Tests for Cord-Connected Products .45 36 Electric Shock Current Test .48A 37 Overload Test 52 37.1 General .52 37.2 Separately energized circuits 52 38 Endurance Te
25、st 52 38.1 General .52 38.2 Separately energized circuits 52 39 Jarring Test 53 40 Dielectric Voltage-Withstand Test .54 41 Temperature Test .54 42 Abnormal Operation Test 58 SEPTEMBER 10, 2010 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODU
26、CTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 43 Electrical Transient Tests 59 43.1 General .59 43.2 Supply line transients .59 43.3 Internally induced transients .59 43.4 Input/output circuit transients 59 44 AC Induction Test .61 45 Polymeric Materials Test .62 46 Battery Replacement Test .62 4
27、7 Drop Test 62 48 Strain Relief Test .63 48.1 Supply Cord .63 48.2 Field-wiring leads .63 49 Ignition Through Bottom-Panel Openings Tests .63 49.1 General .63 49.2 Hot aming oil .63 49.3 Molten pvc and copper 64 50 Mechanical Strength Tests for Enclosures .64 51 Special Terminal Assemblies Tests .65
28、 51.1 General .65 51.2 Disconnection and reconnection .65 51.3 Flexing test 65 51.4 Millivolt drop test .65 51.5 Temperature test .66 PROTECTED PREMISES EQUIPMENT 52 Subscribers Control Units .66 53 Outside Alarm Devices 66 54 Intrusion Detection 67 MERCANTILE PREMISES ALARM SYSTEMS GRADE A REQUIREM
29、ENTS 55 Construction .67 56 Circuit and Operation 67 57 Maintenance .68 58 Attack Tests 69 58.1 General .69 58.2 Test method .69 59 Tamper Protection 70 60 Circuit and Operation 71 MERCANTILE SAFE AND VAULT ALARM SYSTEMS DETAILS 61 General 72 62 Circuit and Operation 72 SEPTEMBER 10, 2010 LOCAL BURG
30、LAR ALARM UNITS AND SYSTEMS - UL 609 4AUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL BANK SAFE AND VAULT ALARM SYSTEMS DETAILS 63 General 72 64 Circuit and Operation 72 65 Maintenance .74 66 Attack Test .75 GRADE A REQUIREMENTS DELETED 67
31、General 76 68 Tamper Protection 76 69 Circuit and Operation 76A GRADE B REQUIREMENTS DELETED 70 General 76A 71 Tamper Protection .76A 72 Circuit and Operation 76A POWER SUPPLIES DETAILS 73 General 76A RECHARGEABLE (SECONDARY) BATTERIES 74 General 76B NONRECHARGEABLE (PRIMARY) BATTERIES 75 General 77
32、 PERFORMANCE 76 Power Failure Test 78 SHORT RANGE RADIO FREQUENCY (RF) DEVICES 77 General 80 78 Time to Report Alarm 80A 79 Inoperative Transmitter Reporting .80A 80 Battery Status Indication .81 81 Tamper Protection 81 82 Interference Protection 81 83 Reference Level Determination .82 83.1 General
33、.82 83.2 Method I 82 83.3 Method 2 84 84 Interference Immunity .86 85 Frequency Selectivity 87 SEPTEMBER 10, 2010 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 4BUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 86 Clash 88 87 Clash Error 88
34、88 Error (Falsing) Rate .89 89 Throughput Rate 90 90 Transmitter Stability Test 91 91 Transmitter Accelerated Aging Test .91 92 Installation Instructions and User Manual 91 MANUFACTURING AND PRODUCTION LINE TESTS FOR HIGH-VOLTAGE PRODUCTS 93 General 92 94 Production Line Dielectric Voltage-Withstand
35、 Test 92 95 Production Line Grounding Continuity Test .93 MARKING 96 General 93 97 Marking Permanency Tests 95 OUTDOOR USE EQUIPMENT 98 Assembly 95 98.1 General .95 99 Construction .96 99.1 General .96 99.2 Corrosion protection 96 100 Field-Wiring Connections .98 101 Internal Wiring .98 102 Componen
36、ts, Electrical Insulating Material 99 PERFORMANCE 103 Rain Test .99 104 Dust Test 103 105 Variable Ambient Test .103 106 Metallic Coating Thickness Test 103 107 Corrosion Tests 105 107.1 General .105 107.2 Salt spray (Fog) 106 107.3 Moist hydrogen sulde (H 2 S) air mixture .106 107.4 Moist carbon di
37、oxide (CO 2 ) sulfur dioxide (SO 2 ) air mixture 106 108 Ultraviolet Light and Water Exposure Test .106 109 Accelerated Aging Tests for Gaskets, Sealing Compounds, and Adhesives 107 MARKING 110 General .109 SEPTEMBER 10, 2010 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 4CUL COPYRIGHTED MATERIAL N
38、OT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 17, 2005 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 4D No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL ACCESSORY EQUIPMENT 111 Ge
39、neral .109 112 Construction .109 113 Performance (Installation) Test .110 114 Markings 110 APPENDIX A Standards for ComponentsA1 FEBRUARY 24, 1999 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM U
40、L This page intentionally left blank. MARCH 17, 2005 LOCAL BURGLAR ALARM UNITS AND SYSTEMS - UL 609 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover construction, performance, and maintenance
41、 of local burglar-alarm units and systems for use in mercantile premises, mercantile safes and vaults, and bank safes and vaults. 1.2 As covered by these requirements, a local alarm system consists of protective circuits and devices, connected through control apparatus to an enclosed tamper-protecte
42、d sounding device mounted on an outside wall of the building in which the protected property is situated. Intrusion into or disturbance of the units or wiring causes the sounding device to be actuated. The sounding device continues to operate until it is stopped by using the proper control key, by e
43、xhaustion of the power supply, or by action of an automatic timing element that is preset for a denite operating period. These systems usually operate within the limits of Class 2 remote control and signal circuits of Class 2 remote control and signal circuits as dened by Article 725 of the National
44、 Electrical Code, NFPA 70. 1.3 The operation of a local alarm system is partially under the control and domination of the owners or others interested in the property. However, it is required that systems be maintained under the care and regular inspection service of the installing company. The insta
45、lling company is expected to respond to troubles or calls for service promptly on report of the owner. See Maintenance, Sections 57 and 65. It is the responsibility of the owner to switch the system ON and OFF duty and to report malfunctioning of the system to the service company. 1.4 Local mercanti
46、le burglar-alarm systems are intended for the protection of mercantile premises or mercantile safes and vaults. Revised 1.4 effective March 17, 2007 1.5 Local bank burglar-alarm systems are intended for the protection of bank safes and vaults. Revised 1.5 effective March 17, 2007 1.6 Equipment inten
47、ded for combination burglar-alarm and re-protective signaling systems shall comply with the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864. 1.6 revised January 6, 2010 1.7 Devices installed on individual properties are further classied as to extent of protection at each lo
48、cation. Rules covering installation and classication (of extent) of alarm equipment at individual locations are published in the Standard for Installation and Classication of Burglar and Holdup Alarm Systems, UL 681, which should be consulted by burglar-alarm installers. Revised 1.7 effective March
49、17, 2007 1.8 A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of re or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials