1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 61800-5-2Standard for Adjustable Speed Electrical Power Drive Systems - Part 5-2: Safety Requirements -FunctionalUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPR
2、ODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 61800-5-2Standard for Adjustable Speed Electrical Power Drive Systems - Part 5-2: Safety Requirements -FunctionalEdition: 1Edition Date: August 28, 2012Adoption of IEC 61800-5-2, Adjustable Speed Electrical Power Drive Syst
3、ems Part 5-2: SafetyRequirements Functional (First edition, issued by the IEC July 2007) as a new IEC-based ULstandard, UL 61800-5-2.Please note that the national difference document incorporates all of the U.S. nationaldifferences for UL 61800-5-2.This document provides a single listing of the Nati
4、onal Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission
5、 of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar
6、damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damag
7、e ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableatt
8、orneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2012 Underwriters Laboratories Inc.AUGUST 28, 2012NATIONAL DIFFERENCES FOR UL UL 61800-5-22UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REP
9、RODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type,
10、 andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are de
11、viations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a
12、particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference enta
13、ils. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding select words
14、 to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or deletion
15、 of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.AUGUST 28, 2012 NATIONAL DIFFERENCES FOR UL UL 61800-5-2 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1DV.
16、1 D2 Modification to scope by adding the following:1DV.1.1 This document is only applicable to the power conversion and drive controlequipment, servo drives and integral servo drive/motor combinations.1DV.1.2 Only devices connected to line voltages of up to 1.5 kV a.c. are covered.1DV.2 DR Modificat
17、ion to scope by adding the following:This equipment is for use in ordinary locations (unclassified locations) in accordance withthe National Electrical Code, NFPA 70.1DV.3 D1 Modification to scope by adding the following:1DV.3.1 Requirements with respect to electrical, thermal and energy safety cons
18、iderationsare covered in the Standard for Adjustable Speed Electrical Power Drive Systems Part5-1: Safety Requirements Electrical, Thermal and Energy, UL 61800-5-1 or the Standardfor Power Conversion Equipment, UL 508C.1DV.3.2 For the purposes of this standard, all PDS(SR) are considered to be in hi
19、ghdemand or continuous mode.2DV.1 D2 Modification by adding the following to 2:IEC 61000-1-2: 2008,Electromagnetic compatibility (EMC) Part 1-2: General Methodology for theachievement of functional safety of electrical and electronic systems including equipmentwith regard to electromagnetic phenomen
20、aIEC 62061:2005,Safety of machinery Functional safety of safety-related electrical, electronic andprogrammable electronic control systems2DV.2 D2 Modification by adding the following to 2:See Annex 101.DVA for U.S. Normative References and Component Standards. See Annex101.DVB for IEC Normative Refe
21、rences that do not apply and for IEC Normative Referencesreplaced by U.S. Standards.Table 1DV DE Modification of Table 1:AUGUST 28, 2012NATIONAL DIFFERENCES FOR UL UL 61800-5-24UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 1DV Alphabet
22、ical list of definitionsTerm Definition number Term Definition numbercommon cause failure 3.1 safe failure 3.14dangerous failure 3.2 safe failure fraction (SFF) 3.15diagnostic coverage (DC) 3.3 safety function(s) (of aPDS(SR)3.16diagnostic test(s) 3.4 safety integrity 3.17fault reaction function 3.5
23、 safety integrity level (SIL) 3.18functional safety 3.6 safety-related system 3.19hazard 3.7 safety requirementsspecification (SRS)3.20installation 3.8 SIL capability 3.21mission time 3.9 subsystem 3.22mode of operation 3.10 systematic failure 3.23PDS(SR) 3.11 systematic safety integrity 3.24PFH 3.1
24、2 validation 3.25proof test 3.13 verification 3.264.1DV.1 DE Modification to 4.1 by adding the following note to the third paragraph:NOTE Integrity could address mechanical, ergonomic, electrical and communication considerations.Reference 5.4.2, 6.1.8, 6.2.4.1.2 and 6.4 for additional information.4.
25、1DV.2 DE Modification to 4.1 by adding the following note to the fourth paragraph:NOTE “Monitoring only” may or may not include a reaction when limits are exceeded or when there isa lack of communication with other safety system components.6.1.2DV D2 Modification of 6.1.2 by adding the following:The
26、 PDS(SR) shall be designed in accordance with the Standard for Adjustable SpeedElectrical Power Drive Systems Part 5-1: Safety Requirements Electrical, Thermal andEnergy, UL 61800-5-1, and, as necessary, other applicable standards of the IEC 61800series.6.2.5.1DV D2 Modification of 6.2.5.1 by adding
27、 the following:The Standard for Adjustable Speed Electrical Power Drive Systems Part 3: EMCRequirements and Specific Test Methods, IEC 61800-3, does not apply to non-safetyrelated functions of the PDS(SR) on the basis that analysis has determined that thenon-safety related functions do not interact
28、with the safety related functions.6.2.5.2DV D2 Modification of 6.2.5.2 by adding the following:6.2.5.2DV.1 In no case shall the test levels used be less than those required in theStandard for Adjustable Speed Electrical Power Drive Systems Part 3: EMCRequirements and Specific Test Methods, IEC 61800
29、-3.AUGUST 28, 2012 NATIONAL DIFFERENCES FOR UL UL 61800-5-2 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL6.2.5.2DV.2 Where the EM environment is not known by the PDS(SR) manufacturer, thetest levels used for the safety related functions sh
30、all be based on the levels in the Standardfor Safety of Machinery Functional Safety of Safety-Related Electrical, Electronic andProgrammable Electronic Control Systems, IEC 62061. Where the application is outside ofthe scope of IEC 62061, the methods indicated in the Standard for ElectromagneticComp
31、atibility (EMC) Part 1-2: General Methodology for the Achievement of FunctionalSafety of Electrical and Electronic Systems Including Equipment with Regard toElectromagnetic Phenomena, IEC 61000-1-2, or another appropriate safety-related systemstandard can be employed.6.2.6DV D2 Addition:6.2.6DV.1 El
32、ectromagnetic emissions requirements of a PDS(SR)6.2.6DV.1.1 A PDS(SR) shall comply with the high frequency electromagnetic emissionsrequirements specified in the Standard for Adjustable Speed Electrical Power DriveSystems Part 3: EMC Requirements and Specific Test Methods, IEC 61800-3.Requirements
33、for low frequency electromagnetic emissions are not applicable.6.5.1DV D1 Modification to 6.5.1 by adding the following:In addition to applying the requirements for hardware integration, a PDS(SR) shall complywith the appropriate requirements: in 6.2.5; type testing in accordance with the Standardfo
34、r Adjustable Speed Electrical Power Drive Systems Part 5-1: Safety Requirements Electrical, Thermal and Energy, UL 61800-5-1; and either the Standard for AdjustableSpeed Electrical Power Drive Systems Part 1: General Requirements RatingSpecifications for Low Voltage Adjustable Speed d.c. Power Drive
35、 Systems, NEMA ICS61800-1, the Standard for Adjustable Speed Electrical Power Drive Systems Part 2:General Requirements Rating Specifications for Low Voltage Adjustable Frequency a.c.Power Drive Systems, NEMA ICS 61800-2, or the Standard for Adjustable Speed ElectricalPower Drive Systems Part 4: Gen
36、eral Requirements Rating Specifications for a.c.Power Drive Systems above 1 000 V a.c. and not Exceeding 35 kV, NEMA ICS 61800-4, asappropriate.7.1DV D1 Modification to 7.1(c):Reference should be made to NEMA ICS 61800-1 or NEMA ICS 61800-2 or NEMA ICS61800-4, and UL 61800-5-1.10.2.5DV D2 Addition:1
37、0.2.5DV.1 Identification/Marking10.2.5DV.1.1 Sufficient configuration management information shall be provided to theuser to allow the SIL levels to be maintained during the life of the apparatus: During repair/replacement of components; During firmware or hardware updates; and,During product evolut
38、ion by manufacturer.NOTE This could be accomplished by changing part numbers as the product evolution occurs.AUGUST 28, 2012NATIONAL DIFFERENCES FOR UL UL 61800-5-26UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULB.3.1.2.3DV DE Modification to
39、 B.3.1.2.3 by adding the following:NOTE Use of this simplified method may save resources to be expended during detailed analysis butmay result in failure rates S, DDand DUless favorable (i.e. more conservative) than if a detailedanalysis is conducted.C.2DV D2 Modification to C.2 by adding the follow
40、ing:UL 991Standard for Tests for Safety-Related Controls Employing Solid-State DevicesUL 1998Standard for Software in Programmable ComponentsTable D.2DV D2 Modification of Table D.2 by adding the following under the Remarkscolumn:NOTE 3 Compliance with Type 12 requirements is considered to be suffic
41、ient to demonstratecompliance with IP54 requirements. For other enclosure types, NEMA 250 Table A-1 can be used todetermine whether the IP54 requirements are satisfied.NOTE 4 Considering Remark 3), for clarification, dimensioning clearances and creepage distances toexceed those required for PD2 in i
42、tem 2 complies with the requirements for this exclusion.Table D.4DV D1 Modification of Table D.4 by adding the following:The connector shall be examined to determine whether expected mechanical stressescould cause a reduction of clearances or creepage distances.NOTE 1 Concerning Remark 1), transient
43、 control is not specifically assured and the installer needs totake action unless supply is verified to provide the control.NOTE 2 Concerning Remark 2), compliance with Type 12 requirements is considered to be sufficient todemonstrate compliance with IP54 requirements. For other enclosure types, NEM
44、A 250 Table A-1 can beused to determine whether the IP54 requirements are satisfied.Table D.5DV D1 Modification of Table D.5:AUGUST 28, 2012 NATIONAL DIFFERENCES FOR UL UL 61800-5-2 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable D.5DV
45、Electromechanical devices(for example relay, contactor relays)Fault considered Exclusions RemarksAll contacts remain in the energisedposition when the coil is de-energized(for example due to mechanical fault)None All contacts remain in thede-energised position when power isapplied (for example due t
46、omechanical fault, open circuit of coil)NoneContact will not open NoneContact will not close NoneSimultaneous short-circuit betweenthe three terminals of a change-overcontactSimultaneous short-circuit can beexcluded if remarks 1) and 2) arefulfilled.1) The creepage and clearancedistances are dimensi
47、oned to at leastIEC 60664-1:1992 with pollutiondegree 2 / overvoltage category III.2) Conductive parts which becomeloose cannot bridge the insulationbetween contacts and the coil.U.S. Addition: Form designations(contact arrangements) are defined inPart 1, Section 2 of NEMA ICS 5. Forthe purposes of
48、this table, both FormC and Form Z contact arrangementsare categorized as a change-overcontactU.S. Addition: In addition to remarks1) and 2), U.S. addition remark 3) mustbe fulfilled.U.S. Addition: 3) The Normally Openand Normally Closed contacts mustbe connected to the same polarity.Polarity is desc
49、ribed in Part 1, Section9.2 of NEMA ICS 5 (see note). ForForm Z contacts, the Normally Openand Normally Closed contacts mustalso be connected to the same powersource.Short-circuit between two pairs ofcontacts and/or between contacts andcoil terminalShort-circuit can be excluded ifremarks 1) and 2) are fulfilled.Simultaneous closing of normallyopen and normally closed contactsSimultaneous closing of contacts canbe excluded if remark 3) is fulfilled.3) Positively driven (or mechanicallylinked) contacts are used.Note: The i