1、 IEC/TR 62669 Edition 1.0 2011-05 TECHNICAL REPORT Case studies supporting IEC 62232 Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure IEC/TR 62669:2011(E) colour inside THIS PUBLICATION IS COPYRIGHT PROTECTED
2、Copyright 2011 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member
3、 National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. Droits de reproduction rs
4、ervs. Sauf indication contraire, aucune partie de cette publication ne peut tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de la CEI ou du Comit national de la CEI du pays du demandeur
5、. Si vous avez des questions sur le copyright de la CEI ou si vous dsirez obtenir des droits supplmentaires sur cette publication, utilisez les coordonnes ci-aprs ou contactez le Comit national de la CEI de votre pays de rsidence. IEC Central Office 3, rue de Varemb CH-1211 Geneva 20 Switzerland Ema
6、il: inmailiec.ch Web: www.iec.ch About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub T
7、he IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,). It also gives information on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Pub
8、lished details twice a month all new publications released. Available on-line and also by email. Electropedia: www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms i
9、n additional languages. Also known as the International Electrotechnical Vocabulary online. Customer Service Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: cs
10、ciec.ch Tel.: +41 22 919 02 11 Fax: +41 22 919 03 00 IEC/TR 62669 Edition 1.0 2011-05 TECHNICAL REPORT Case studies supporting IEC 62232 Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure INTERNATIONAL ELECTROTE
11、CHNICAL COMMISSION XK ICS 13.280; 17.240 PRICE CODE ISBN 978-2-88912-528-9 Registered trademark of the International Electrotechnical Commission colour inside 2 TR 62669 IEC:2011(E) CONTENTS FOREWORD . 3 INTRODUCTION . 5 1 Scope . 6 2 Normative references . 6 3 Terms, definitions, symbols and abbrev
12、iated terms . 6 4 Overview of case studies 6 4.1 Case study synopsis . 6 4.2 Micro cell case study . 7 4.3 Roof-top case study with nearby apartment buildings 8 4.4 Roof-top / tower case study in residential area 9 4.5 Roof-top case study with direct access to antennas . 10 4.6 Roof-top case study w
13、ith large antennas and no direct access 11 4.7 Circular cylindrical compliance boundary determination case study with large antennas and no direct access 11 4.8 Tower case study in parkland 12 4.9 Multiple towers case study at sports venue 13 4.10 In-building base station case study 14 Annex A (info
14、rmative) Micro cell case study . 16 Annex B (informative) Roof-top case study with nearby apartments . 41 Annex C (informative) Roof-top / tower case study in residential area 68 Annex D (informative) Roof-top case study with direct access to antennas 98 Annex E (informative) Roof-top case study wit
15、h no direct access to antennas 126 Annex F (informative) Circular cylindrical compliance boundary determination case study 143 Annex G (informative) Tower case study in parkland 155 Annex H (informative) Tower case study at sports venue . 170 Annex I (informative) In-building base station case study
16、 . 191 Annex J (informative) Evaluation template and sample uncertainty table 212 Figure 1 Micro cell case study 7 Figure 2 Roof-top case study with nearby apartment buildings . 8 Figure 3 Roof-top / tower case study in residential area . 9 Figure 4 Roof-top case study with direct access to antennas
17、 . 10 Figure 5 Roof-top case study with large antennas and no direct access . 11 Figure 6 Cylindrical compliance boundary determination for dual band antenna on building . 12 Figure 7 Tower case study in parkland . 13 Figure 8 Multiple towers case study at sports venue 14 Figure 9 Office building IB
18、C case study . 15 TR 62669 IEC:2011(E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ CASE STUDIES SUPPORTING IEC 62232 DETERMINATION OF RF FIELD STRENGTH AND SAR IN THE VICINITY OF RADIOCOMMUNICATION BASE STATIONS FOR THE PURPOSE OF EVALUATING HUMAN EXPOSURE FOREWORD 1) The International Electrotech
19、nical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To thi
20、s end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National
21、Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO)
22、in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from
23、 all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be hel
24、d responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any di
25、vergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IE
26、C marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual e
27、xperts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IE
28、C Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IE
29、C Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. The main task of IEC technical committees is to prepare International Standards. However, a technical committee may propose the publication of a technical report when i
30、t has collected data of a different kind from that which is normally published as an International Standard, for example “state of the art“. IEC 62669, which is a technical report, has been prepared by IEC technical committee 106: Methods for the assessment of electric, magnetic and electromagnetic
31、fields associated with human exposure. This publication contains attached files in the form of a CD-ROM for the paper version and embedded files for the electronic version. These files are intended to be used as a complement and do not form an integral part of the technical report. 4 TR 62669 IEC:20
32、11(E) The text of this technical report is based on the following documents: Enquiry draft Report on voting 106/199/DTR 106/208/RVC Full information on the voting for the approval of this technical report can be found in the report on voting indicated in the above table. This publication has been dr
33、afted in accordance with the ISO/IEC Directives, Part 2. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publi
34、cation will be reconfirmed, withdrawn, replaced by a revised edition, or amended. A bilingual version of this publication may be issued at a later date. IMPORTANT The colour inside logo on the cover page of this publication indicates that it contains colours which are considered to be useful for the
35、 correct understanding of its contents. Users should therefore print this document using a colour printer. TR 62669 IEC:2011(E) 5 INTRODUCTION This technical report contains a series of case studies for the evaluation of electromagnetic (EM) sources in the frequency range 100 kHz - 300 GHz to suppor
36、t the methods detailed in the international standard IEC 62232, Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure. Using the methods detailed in the standard, each case study has been chosen to illustrate a typ
37、ical radio base station (RBS) evaluation scenario. 6 TR 62669 IEC:2011(E) CASE STUDIES SUPPORTING IEC 62232 DETERMINATION OF RF FIELD STRENGTH AND SAR IN THE VICINITY OF RADIOCOMMUNICATION BASE STATIONS FOR THE PURPOSE OF EVALUATING HUMAN EXPOSURE 1 Scope This technical report presents a series of c
38、ase studies in which electromagnetic (EM) fields are evaluated in accordance with IEC 62232. It also provides a reporting template cross referenced to IEC 62232. Each case study has been chosen to illustrate a typical radio base station (RBS) evaluation scenario and employs the methods detailed in I
39、EC 62232. Some of the case studies demonstrate more than one evaluation method. However, in most situations only one method would be required to complete an evaluation. The case studies documented in this report are provided for guidance only and are not a substitute for a thorough understanding of
40、the requirements of IEC 62232. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) appl
41、ies. IEC 62232: Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure 3 Terms, definitions, symbols and abbreviated terms For the purposes of this document, the terms, definitions, symbols and abbreviated terms giv
42、en in IEC 62232 apply. 4 Overview of case studies 4.1 Case study synopsis This clause provides a summary of worked evaluation examples at a number of RBS sites using a range of methods described in IEC 62232. The example sites include roof-tops, towers, poles, micro cells and in-building cells. The
43、case studies have been chosen to illustrate typical RBS sites and common evaluations. Some of the case studies demonstrate multiple evaluation methods. However in most situations only one method would be required to complete an evaluation. NOTE The coloured left-side page margins in the annexes indi
44、cates the pages are unchanged versions of sample RF exposure evaluation reports contributed by TC 106 project team members. TR 62669 IEC:2011(E) 7 4.2 Micro cell case study The purpose of this case study was to evaluate the RF exposure compliance boundaries from a particular micro cell installation
45、on a building wall to determine whether they would extend to a nearby awning. Compliance boundaries were determined based on a) basic restrictions and b) reference levels to determine the minimum distance from the antenna to the compliance boundary. The maximum values were compared against internati
46、onal safety guidelines known as ICNIRP (International Commission on Non-Ionizing Radiation Protection) guidelines. The assessment establishes compliance against the basic restrictions known as specific absorption rate (SAR) and the spatially averaged field strength reference levels. SAR testing was
47、performed in a laboratory and frequency selective field measurements were performed on site. The equipment under test (EUT) was categorised as a simple RBS due to the single technology and single antenna of the micro cell. Nearby base stations, known as secondary sources, had negligible impact on bo
48、th SAR and field strength evaluations. The measured SAR and field strength levels were extrapolated to assess the maximum power configuration for the site. The “best estimate” uncertainty model was applied and the measured levels are reported including the extrapolation for maximum base station powe
49、r configuration. The uncertainty is stated for all assessment methods used. The compliance boundary distance for general public exposure using the on-site field strength measurement was 0,8 m and 0,08 m using the SAR evaluation. Both the SAR evaluation and the on-site field strength measurements confirm that the general public exposure compliance boundary from the micro cell antenna does not extend onto the building awning, therefore access is permitted on the awning. Th
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1