1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Thermoplastics piping systems for soil and waste discharge inside buildings - Test method for airtightness of jointsBS EN ISO 13255:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 13255 October 2017 ICS 23.
2、040.20; 91.140.80 Supersedes EN 1054:1995English Version Thermoplastics piping systems for soil and waste discharge inside buildings - Test method for airtightness of joints (ISO 13255:2010) Systmes de canalisations thermoplastiques pour vacuation des eaux-vannes et des eaux uses lintrieur des btime
3、nts - Mthode dessai de ltanchit des assemblages lair (ISO 13255:2010)Rohrleitungssysteme aus Thermoplasten zum Ableiten von Abwasser innerhalb von Gebuden - Prfverfahren fr die Gasdichtheit von Verbindungen (ISO 13255:2010) This European Standard was approved by CEN on 19 September 2017. CEN members
4、 are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application
5、to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
6、 Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lit
7、huania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Mar
8、nix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 13255:2017 ENational forewordThis British Standard is the UK implementation of EN ISO 13255:2017, incorporating correction notice 31 January 2018. It
9、is identical to ISO 13255:2010. It supersedes BS ISO 13255:2010 and BS EN 1054:1996, which are withdrawn.The UK participation in its preparation was entrusted to Technical Committee PRI/88, Plastics piping systems.A list of organizations represented on this committee can be obtained on request to it
10、s secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2018 Published by BSI Standards Limited 2018ISBN 978 0 580 97994 1ICS 91.140.80; 23.040.20Compliance with a Britis
11、h Standard cannot confer immunity from legal obligations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2010.Amendments/corrigenda issued since publicationDate Text affected30 June 2018 This corrigendum renumbers BS ISO 13255:2010 a
12、s BS EN ISO 13255:201730 June 2018 Implementation of CEN correction notice 31 Janu-ary 2018: DOW corrected in the forewordBRITISH STANDARDBS EN ISO 13255:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 13255 October 2017 ICS 23.040.20; 91.140.80 Supersedes EN 1054:1995English Version Th
13、ermoplastics piping systems for soil and waste discharge inside buildings - Test method for airtightness of joints (ISO 13255:2010) Systmes de canalisations thermoplastiques pour vacuation des eaux-vannes et des eaux uses lintrieur des btiments - Mthode dessai de ltanchit des assemblages lair (ISO 1
14、3255:2010)Rohrleitungssysteme aus Thermoplasten zum Ableiten von Abwasser innerhalb von Gebuden - Prfverfahren fr die Gasdichtheit von Verbindungen (ISO 13255:2010) This European Standard was approved by CEN on 19 September 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulati
15、ons which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
16、This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN m
17、embers are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Por
18、tugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation
19、 in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 13255:2017 EBS EN ISO 13255:2017EN ISO 13255:2017 (E) 3 European foreword The text of ISO 13255:2010 has been prepared by Technical Committee ISO/TC 138 “Plastics pipes, fittings and valves for the transport o
20、f fluids” of the International Organization for Standardization (ISO) and has been taken over as EN ISO 13255:2017 by Technical Committee CEN/TC 155 “Plastics piping systems and ducting systems” the secretariat of which is held by NEN. This European Standard shall be given the status of a national s
21、tandard, either by publication of an identical text or by endorsement, at the latest by April 2018, and conflicting national standards shall be withdrawn at the latest by October 2020. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent right
22、s. CEN shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1054:1995. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgiu
23、m, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
24、Switzerland, Turkey and the United Kingdom. Endorsement notice The text of ISO 13255:2010 has been approved by CEN as EN ISO 13255:2017 without any modification. BS EN ISO 13255:2017ISO 13255:2010(E) ISO 2010 All rights reserved iiiForeword ISO (the International Organization for Standardization) is
25、 a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represen
26、ted on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are dr
27、afted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International S
28、tandard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 13255 was prepare
29、d by Technical Committee ISO/TC 138, Plastics pipes, fittings and valves for the transport of fluids, Subcommittee SC 1, Plastics pipes and fittings for soil, waste and drainage (including land drainage). BS EN ISO 13255:2017INTERNATIONAL STANDARD ISO 13255:2010(E) ISO 2010 All rights reserved 1Ther
30、moplastics piping systems for soil and waste discharge inside buildings Test method for airtightness of joints 1 Scope This International Standard specifies a method for testing the airtightness of joints of thermoplastics piping systems for soil and waste discharge inside buildings. 2 Principle A t
31、est assembly of pipes and/or fittings is subjected to a given internal air pressure for a given time period during which the leaktightness of the joint is verified by inspection. NOTE It is assumed that the following test parameters are set by the referring standard: a) the sampling procedure (see 4
32、.1 and Clause 5); b) the number of test pieces (see 4.2). 3 Apparatus 3.1 End-sealing devices, having a size and using a sealing method that are appropriate to the type of joint assembly under test. The devices shall be restrained in such a manner that does not exert longitudinal forces on the joint
33、 assembly and prevents the devices or the assembly under test from separating under pressure. The mass of the devices shall not be permitted to influence the angular deflection to be applied (see 5.8). 3.2 Air pressure source, connected via a shut-off valve to one end of at least one end-sealing dev
34、ice, and capable of maintaining the required pressure within 10 % (see Clause 5). 3.3 Pressure-measuring device, capable of checking conformity to the required test pressure (see 3.2 and Clause 5). 3.4 Water supply and outlet devices, each connected via a shut-off valve to at least one end-sealing d
35、evice to admit water to the appropriate level within the test piece (see Figure 1). BS EN ISO 13255:2017ISO 13255:2010(E) 2 ISO 2010 All rights reserved4 Test pieces 4.1 Preparation of test pieces The test piece shall comprise an assembly of (a) pipe section(s) (with or without sockets) and/or fitti
36、ng(s), one part of the test piece being a pipe or a fitting with a spigot mounted in two clamped blocks (see Figure 1). Dimensions in millimetres Key 1 fixed points 2 sealing plug with water outlet and end restraint (see 3.1) 3 loose bushes enabling all sizes of pipes to be accommodated on the same
37、test fixture 4 fixed component 5 sealing plug with water inlet, air outlet and end restraint aWater inlet. bAir outlet. cLevel of water for test (half of pipe internal bore). dWater outlet. eDirection of movement for angular deflection, if applicable (see 5.8). Figure 1 Typical arrangement One end o
38、f the pipe shall be sealed with a plug that has a combined water and air inlet. A fitting or a joint shall be assembled with the open end of the fixed component. The fitting or joint shall then be sealed at all open ends with plugs, one of which has a centrally mounted water outlet and shut-off valv
39、e (see Figure 2). The assembly of the joint(s) shall be carried out in accordance with the manufacturers instructions. The assembly shall comprise the combination of the smallest available spigot end and the largest available socket or socket groove diameter within the applicable tolerance(s) and ob
40、tained by sampling in accordance with the referring standard. The relevant diameters of the selected spigots and sockets shall be measured and recorded. 4.2 Number of test pieces The number of test pieces shall be specified in the referring standard. BS EN ISO 13255:2017ISO 13255:2010(E) ISO 2010 Al
41、l rights reserved 35 Procedure 5.1 Carry out the following procedure at a temperature of (23 5) C using cold tap water, without permitting any condensation to form on the surface of the test piece. 5.2 Mount the test piece horizontally in the apparatus (see Figure 1). 5.3 When testing in accordance
42、with 5.4 to 5.8, monitor the joint for and record any leaks which are evident by the formation of bubbles of soap solution (see 5.4) and the escape of water. 5.4 Apply a solution of soapy water or equivalent leak-detecting agent around the annular space between the spigot and the mouth of the socket
43、. Afterwards, remove any excess, dripping liquid with a dry cloth. 5.5 Open the water outlet valve and close the air inlet valve. 5.6 Open the water inlet valve. When the assembly is half-full, as indicated by water flow from the outlet, close first the water inlet valve and then the water outlet va
44、lve. 5.7 Open the air inlet valve and increase the internal air pressure to (0,1 0,01) bar1)using air at the temperature specified in 5.1. 5.8 Maintain this pressure for 5 min, then deflect the fitting or joint manually on the spigot end of the clamped component, until their consecutive axes reach t
45、he maximum angular deflection, as stated by the manufacturer for the specific joint under test. Apply this angular deflection at 0, 90, 180 and 270 (see Figure 2), maintaining it for 1 min in each of these directions. 5.9 Depressurize, drain and dismantle the test piece. Inspect for and record any c
46、hanges in the appearance of the components tested. Key 1 blocks split and held together with wing-nut 2 sealing plug aDirection of movement of fitting during test (end elevation). Figure 2 Directions of deflection 1) 1 bar = 0,1 MPa = 105Pa; 1 MPa = 1 N/mm2. BS EN ISO 13255:2017ISO 13255:2010(E) 4 I
47、SO 2010 All rights reserved6 Test report The test report shall include the following information: a) a reference to this International Standard, i.e. ISO 13255:2010, and the referring standard; b) the complete identification of the components (e.g. fittings, pipes, assemblies) comprising the joints
48、under test and their respective diameters, in millimetres (see 4.1); c) the test temperature (see 5.1), in degrees Celsius; d) the test pressure, in bar; e) the time period under pressure, in minutes; f) the angle of deflection applied to the joint, if applicable (see 5.8); g) a statement that the j
49、oint did not leak or, if applicable, a report of the signs of leakage or rupture, their position(s) and the pressure at which they occurred; h) any change in the appearance of the components of the test piece(s) during testing, or immediately afterwards; i) any factor that could have affected the results, such as any incident or any operating details not specified in this International Standard; j) the date of the test. BS EN ISO 13255:2017This page deliberately left blankBSI is the national body re
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1