ImageVerifierCode 换一换
格式:PDF , 页数:32 ,大小:2MB ,
资源ID:398977      下载积分:5000 积分
快捷下载
登录下载
邮箱/手机:
温馨提示:
快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。 如填写123,账号就是123,密码也是123。
特别说明:
请自助下载,系统不会自动发送文件的哦; 如果您已付费,想二次下载,请登录后访问:我的下载记录
支付方式: 支付宝扫码支付 微信扫码支付   
验证码:   换一换

加入VIP,免费下载
 

温馨提示:由于个人手机设置不同,如果发现不能下载,请复制以下地址【http://www.mydoc123.com/d-398977.html】到电脑端继续下载(重复下载不扣费)。

已注册用户请登录:
账号:
密码:
验证码:   换一换
  忘记密码?
三方登录: 微信登录  

下载须知

1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。
2: 试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。
3: 文件的所有权益归上传用户所有。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 本站仅提供交流平台,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

版权提示 | 免责声明

本文(BS PD ISO TS 18870-2014 Lifts (elevators) Requirements for lifts used to assist in building evacuation《升降机 (电梯) 用于协助建筑疏散的升降机的要求》.pdf)为本站会员(李朗)主动上传,麦多课文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文库(发送邮件至master@mydoc123.com或直接QQ联系客服),我们立即给予删除!

BS PD ISO TS 18870-2014 Lifts (elevators) Requirements for lifts used to assist in building evacuation《升降机 (电梯) 用于协助建筑疏散的升降机的要求》.pdf

1、BSI Standards Publication PD ISO/TS 18870:2014 Lifts (elevators) Requirements for lifts used to assist in building evacuationPD ISO/TS 18870:2014 PUBLISHED DOCUMENT National foreword This Published Document is the UK implementation of ISO/TS 18870:2014. The UK participation in its preparation was en

2、trusted to Technical Committee MHE/4, Lifts, hoists and escalators. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct applic

3、ation. The British Standards Institution 2014. Published by BSI Standards Limited 2014 ISBN 978 0 580 85218 3 ICS 91.140.90 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of the Standards Policy and Strategy

4、 Committee on 31 August 2014. Amendments issued since publication Date Text affectedPD ISO/TS 18870:2014 ISO 2014 Lifts (elevators) Requirements for lifts used to assist in building evacuation Ascenseurs Exigences pour les ascenseurs utiliss en cas dvacuation de btiments TECHNICAL SPECIFICATION ISO/

5、TS 18870 First edition 2014-08-15 Reference number ISO/TS 18870:2014(E)PD ISO/TS 18870:2014ISO/TS 18870:2014(E)ii ISO 2014 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2014 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in

6、 any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case po

7、stale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in SwitzerlandPD ISO/TS 18870:2014ISO/TS 18870:2014(E) ISO 2014 All rights reserved iii Contents Page Foreword iv Introduction v 1 Scope . 1 2 Normative references 1 3 T erms and

8、 definitions . 1 4 A ut omatic e v acuation lift specification 3 4.1 Determining the number and size of lifts 3 4.2 Protection of lift equipment 3 4.3 Waiting and travelling environment for users . 4 4.4 Removal or suspension of lifts from evacuation service . 4 4.5 Lift system reliability . 4 4.6 A

9、utomatic recovery system 4 4.7 Remote lift car surveillance . 5 4.8 Communication system requirements . 5 4.9 Lift signs and passenger announcements 6 4.10 Prevention and detection of car overloading 6 4.11 Initiation of evacuation service 6 4.12 Description of evacuation service 6 4.13 Removal of l

10、ifts cars from service . 8 4.14 Change of main evacuation exit floor (MEEF) 9 4.15 Cancellation of evacuation service . 9 5 Information to be provided to the building owner . 9 6 Other information to be provided .10 Annex A (informative) Building design considerations for automatic lift e v acuation

11、 specification 11 Annex B (informative) Information to be provided .19 Bibliography .21PD ISO/TS 18870:2014ISO/TS 18870:2014(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing Internat

12、ional Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with I

13、SO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, P

14、art 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of th

15、e elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations r

16、eceived (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement. For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISO

17、s adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information The committee responsible for this document is ISO/TC 178, Lifts, escalators, and moving walks.iv ISO 2014 All rights reservedPD ISO/TS 18870:2014ISO/TS 18870:2014(E

18、) Introduction This Technical Specification has been prepared in response to ISO/TC 178 Resolution 273/2007 in which the Technical Committee requested that WG 6 undertake to write a specification for lift features that if incorporated into an appropriate lift would enable it to be used in safety to

19、evacuate persons from a building that was suitably designed. This work results from a detailed study undertaken by TC 178/WG6 into the feasibility of using lifts for evacuation of persons. The study ISO/TR 25743 indicated that it was feasible to use lifts, provided that certain features were incorpo

20、rated in the lift and also in the building. Lift engineers and other specialists have been involved in the production of this specification. It has been recognized that lift engineers are not experts in building design or fire engineering. The writing of this Technical Specification does not indicat

21、e if it is acceptable or permitted to use lifts for building evacuations. It only indicates the features required should those persons responsible wish to make such a decision. This Technical Specification does not define, in any detail, building features that will have to be provided in conjunction

22、 with a lift intended to be used for evacuation. Its aim is to make clear to those persons involved in building design and fire engineering the issues that they shall address to enable the lift to be used safely. There are many reasons why a building might need to be evacuated, such as a fire, explo

23、sion, chemical or biological attack, flooding, storm damage, earthquake, etc. Not all of these are relevant to every building and other hazardous situations, while existing, are so unlikely to occur that they can be disregarded. Designers of buildings have to determine if a particular hazard is suff

24、iciently great as to require addressing. If, for example, a small office block is being designed that will be located in a mid-town area, it is within the realm of possibility that it could be subjected to an explosion or chemical attack (terrorism). It is not, however, very likely to be the case un

25、less it has some particular reason to make it vulnerable. In most cases, the risk of these events is probably so low as to make it unnecessary for them to be addressed. If the building is to be the headquarters of National Security, this will increase the likelihood of it being subjected to some for

26、m of attack. It might be necessary to consider the effects of an explosion in or close to the building or a chemical agent being introduced into the building. Clearly, a building constructed in an area where earthquakes do not normally occur need not have provisions made for such an event. If a buil

27、ding is to be built in the centre of a major city to form a prestigious landmark, it might be essential to consider all likely events that could occur. The designer of the building has to determine, by risk assessment or other methods, what hazardous events needs to be reasonably addressed. Once thi

28、s is completed, ISO/TR 25743 can be used to understand the lift and building features that might be required for each evacuation scenario envisaged. A lift or lifts can enable disabled persons to evacuate a building in relative ease, but if it is thought, lifts could play a role in general evacuatio

29、n, they might or might not make a significant contribution to reducing the general evacuation time. It will depend on the building size, number of lifts, etc. This Technical Specification defines lift requirements to address common hazards that all users could be exposed to if lifts are used for eva

30、cuation. Even if it is thought that lifts could play a part in a general evacuation, it might prove to be uneconomical. It is not suggested for lifts to replace or change the requirements for escape stairs, and that using lifts instead of stairs can increase evacuation times in many building designs

31、. The intention is to allow lifts to play a positive role in assisting and improving the efficiency of the building evacuation strategy. This Technical Specification is divided into sections covering the key items that have to be addressed. There is no priority intended from the order in which the i

32、tems are listed. ISO 2014 All rights reserved vPD ISO/TS 18870:2014PD ISO/TS 18870:2014Lifts (elevators) Requirements for lifts used to assist in building evacuation 1 Scope This Technical Specification details requirements for passenger carrying lifts, which are installed in buildings having a suit

33、able comprehensive building evacuation strategy. It does not define building requirements that will have to be provided as part of the overall evacuation strategy for the building. Excluded from this Technical Specification are the following: details of a building evacuation strategy; details of bui

34、lding features to reduce risks or eliminate hazards; national building requirements which might demand special features. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, o

35、nly the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 4190-5, Lift (Elevator) installation Part 5: Control devices, signals and additional fittings 3 T erms a nd definiti ons For the purposes of this document, the

36、 following terms and definitions apply. 3.1 Alternative Evacuation Exit Floor AEEF level defined by the building designer to be used for evacuation when systems or management determine it should be used 3.2 Building Management System BMS system capable of making appropriate decisions based on inform

37、ation sent to it 3.3 chemical incident introduction of a gas, chemical, bacterial agent, or substance into the building 3.4 building management persons or organization responsible for ensuring the day-to-day safe efficient running of the building and for ensuring the building is safely evacuated in

38、line with the evacuation strategy 3.5 ETA estimated time of arrival of the lift TECHNICAL SPECIFICATION ISO/TS 18870:2014(E) ISO 2014 All rights reserved 1PD ISO/TS 18870:2014ISO/TS 18870:2014(E) 3.6 f ire combustion of material producing, heat, sometimes smoke, and/or flame 3.7 Fire Command Centre

39、FCC room or area provided in the building where information is displayed showing the status of a fire detection system and lifts, etc. and where management can receive audible and visual information to determine what actions to take if lifts are to be used 3.8 f i r e c omp a r t ment f i r e s e p

40、a r a t e d a r e a area within a building bounded by walls, floor, and ceiling constructed from fire resisting material so as to provide resistance to fire for a defined period 3.9 f i r e w a r d e n person appointed by the building management to assist in managing the evacuation of a floor or are

41、a of building during an emergency 3.10 hazardous area area where due to heat, smoke, gas, etc. the environment is considered dangerous to persons 3.11 hazard detection system system of sensors capable of automatically detecting fire, smoke, gas, etc 3.12 impaired mobility difficulty in using stairs

42、because of a physical impairment 3.13 lift evacuation time time a person spends using a lift to evacuate Note 1 to entry: It is expressed in s. Note 2 to entry: This is measured from initiation of evacuation service for a given floor plus the time spent travelling to the floor plus the time to open

43、doors, load the car return nonstop to main exit for evacuation, open doors, and empty lift car. 3.14 Main Evacuation Exit Floor MEEF floor designated by the building designer where persons should exit lifts to leave the building Note 1 to entry: This might or might not be the normal exit floor or gr

44、ound floor of the building. 3.15 required lift evacuation handling capacity number of persons who can be moved to the main evacuation exit floor in a five-minute period, expressed as a percentage of the total number of persons to be evacuated by lifts Note 1 to entry: This is not to be confused with

45、 normal lift handling capacity. 3.16 required lift evacuation time time measured from start of the lift evacuation service to completion of the evacuation of a floor or number of floors2 ISO 2014 All rights reservedPD ISO/TS 18870:2014ISO/TS 18870:2014(E) 3.17 safe area s a f e f l o o r area of the

46、 building, where it is known that heat, smoke, etc. are not present and where it will be safe for people to wait, travel in, or leave the lift 3.18 total lift evacuation time time required to move all persons requiring evacuation by lifts to the Main Evacuation Exit Floor (3.14) Note 1 to entry: Thi

47、s time is measured from start of evacuation service with lift(s) at MEEF to evacuation of all persons and return of lifts to the MEEF. 3.19 building sign information display provided by the building, not the lift, informing building users of the location of evacuation lifts available for use 4 A ut

48、oma tic e v acuation lift specification 4.1 Determining the number and size of lifts To calculate the number and size of lifts required to provide an adequate evacuation service, the handling capacity of a given lift or group of lifts shall be determined. To calculate lift handling capacity, the lif

49、t designer will require certain information as detailed in Annex B. Any other building specific information that might affect the handling capacity or assist the lift designer in understanding the issues related to the evacuation strategy should also be provided. It shall be recognized that there is always a reasonable possibility that a lift or lifts might not be available for some reason. This might occur due to planned maintenance, repairs, etc. An allowance should be made in the handling capacity calculations to take account of this. Thi

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1