1、AECMA STANDARD NORME AECMA AECMA NORM prEN 41 65-005 Edition P 1 December 2001 PUBLISHED BY THE EUROPEAN ASSOCIATION OF AEROSPACE INDUSTRIES - STANDARDIZATION (AECMA-STAN) Gulledelle 94 - 6-1200 BRUXELLES - Tel. (+32) 2 775 81 10 - Fax. (+32) 2 775 81 1 1 ICs: Descriptors: ENGLISH VERSION Aerospace
2、series Connectors, electrical, rectangular, modular Operating temperature 175 “C continuous Part 005: Stackable mounting receptacle 2 and 4 modules series 3 Srie arospatiale Luft- und Raumfahrt Connecteurs lectriques rectangulaires modulaires Temprature dutilisation 175 “C continu Partie 005 : Embas
3、e empilable 2 et 4 modules, srie 3 Elektrische Rundsteckverbinder Dauebetriebstemperaturen 175 “C konstant Teil 005: Plutton steckverbinder, 2 und 4 module, serie 3 This “Aerospace Series“ Prestandard has been drawn up under the responsibility of AECMA-STAN (The European Association of Aerospace Ind
4、ustries - Standardization). It is published on green paper for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be change
5、d fo an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of AECMA-STAN it will be submifted as a draft European Standard to CEN (European Committee for Standardization) for fo
6、rmal vote. Nota - Extra copies can be supplied by B.N.A.E. - Technopolis 54 - 199, rue Jean-Jacques Rousseau - 92138 ICSY-LES-MOULINEAUX CEDEX - Edition approved for publication I Comments should be sent within six months I Electrical Domain 2001-12-28 after the date of publication to Gulledelle 94
7、AECMA-STAN 6-1200 BRUXELLES Mr Peuetta 1 I 0 aecma 2001 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 2 prEN 41 65-005: 2001 Blank page Copyrigh
8、t Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 3 prEN 4165-005: 2001 1 Scope This standard defines the stackable mounting receptacle series 3, for 2 or 4
9、 modules used in the family of rectangular electrical modular connectors, operating temperature 175 “C continuous. The plug corresponding to those receptacle are defined in EN 4165-002. The protective cover corresponding to those receptacle are defined in EN 41 65-018. 2 Norm at ive references This
10、European standard incorporates by dated or undated reference provisions from other publications. The normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references subsequent amendments to or revisions of any of these publications
11、 apply to this European standard only when incorporated in it by amendment or revision. For undated references the lasted edition of the publication refereed to applies. EN 2424 Aerospace series - Marking of aerospace product EN 41 65-001 Aerospace series - Connectors, electrical, rectangular, modul
12、ar - Operating temperature 175 “C continuous - Part O01 : Technical specification - Product standard 1) EN 41 65-002 Aerospace series - Connectors, electrical, rectangular, modular - Operating temperature 175 “C continuous - Part 002: Specification of performance and contact arrangements 1) EN 41 65
13、-003 Aerospace series - Connectors, electrical, rectangular, modular - Operating temperature 175 “C continuous - Part 003: Modules series 2 and series 3 - Product standard 1) EN 41 65-01 8 Aerospace series - Connectors, electrical, rectangular, modular - Operating temperature 175 “C continuous - Par
14、t 018: Protective cover for receptacle 2 or 4 modules, series 2 and series 3 - Product standard 2) EN 41 65-020 Aerospace series - Connectors, electrical, rectangular, modular - Operating temperature 175 “C continuous - Part 020: Coupling system Keyway for receptacle - Product standard 2) 3 Term i n
15、o1 og y See EN 4165-001. 4 Required characteristics See figures 1 and 2. 1) Published as AECMA Prestandard at the date of publication of this standard. 2) In preparation at the date of publication of this standard. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by
16、 IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 4 prEN 4165-005: 2001 5 5.1 For 2 modules See EN 41 65-003. Dimensions are in millimetres. Stackable mounting receptacle for male or female modules 44.52 p-44.42 -1 15 20 1 maxi r O0
17、49.62 4 z: 49.42 Figure 1 Mass (9) = 19,OO Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 5 prEN 4165-005: 2001 Classes W 5.2 For 4 modules See E
18、N 4165-003. Dimensions are in millimetres. Description Receptacle with housing (shell) olive drab cadmium plated, aluminium alloy, conducting finish, 500 h resistance to salt mist. Rectangular grounding device, or not, maximum operating temperature 175 “C continuous II ,1 75.00 74.90 80.10 79.90 81.
19、10 cT,Ss“eF pn# for 00.90 and A Figure 2 Mass (9) = 24,80 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 6 prEN 41 65-005: 2001 Number of the bas
20、ic standard Class (see table 1) Type O = Receptacle (see EN 41 65-002) Type B = Series 3 Shell type 6 Designation EXAMPLE: 4 = Stackable receptacle 4 modules 2 = Stackable receptacle 2 modules Receptacle keying coupling (see EN 41 65-020) Not marked on the connector Dash = Not delivered O = Universa
21、l Special coding 4 5 6 State of delivery receptacle keying coupling (see EN 41 65-020) I Not marked on the connector O = Delivered not mounted Mounting in the receptacle 4 5 6 7 Marking Unless there are other specific contractual requirements, the marking shall be in accordance with EN 2424, category P. *. 8 Technical specification See EN 4165-001. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-