1、AECMA STANDARD NORME AECMA AECMA NORM Edition approved for publication 31 July 2004 prEN 461 1-002 Edition P 1 July 2004 Comments should be sent within six months after the date of publication to Electrical Domain AECMA-STAN ICs: Descriptors: ENGLISH VERSION Aerospace series Cables, electrical, for
2、general purpose, single and multicore assembly XLETFE Family Part 002: General Srie arospatiale Cbles, lectriques, dusage gnral, mono et multiconducteurs Famille XLETFE Partie 002 : Gnralits Luft- und Raumfahrt Ein- und mehradrige elektrische Leitungen fr allgemeine Vewendung XLETFE Familie Teil 002
3、: Allgemeines This “Aerospace Series“ frestandard has been drawn up under the responsibility of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the co
4、ncerned Domain following member comments. Subsequent to the publication of this frestandard, the technical content shall not be changed to an extent that interchangeabilify is affected, physically or functionally, without re-identification of the standard. After examination and review by users and f
5、ormal agreement of AECMA-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the sta
6、tus of a national standard and by withdrawing any national standards conflicting with the EN. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 2 prEN
7、 461 1-002:2004 Foreword This standard was reviewed by the Domain Technical Coordinator of AECMA-STANS Electrical Domain. After inquiries and votes carried out in accordance with the rules of AECMA-STAN defined in AECMA- STANS General Process Manual, this standard has received approval for Publicati
8、on. Contents Page 1 2 3 4 5 5.1 5.2 6 7 Scope Normative references . Definitions and symbols . List of product standards Materials and construction Materials Construction . Identification and marking Technical specification Copyright Association Europeene des Constructeurs de Materiel Aerospatial Pr
9、ovided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 3 prEN 461 1-002:2004 1 Scope This standard specifies the list of product standards and common characteristics of electrical cables for use in the on-board electrical systems o
10、f aircraft operating at temperatures between - 65 OC or 135 OC, dependant upon conductor type, and 150 OC, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 O00 Hz. (unless otherwise specified in product standards). 2 Normative references This European Standard incorpor
11、ates by dated or undated reference provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. Dated references, subsequent amendments to or revisions of any of these publications apply to this European Sta
12、ndard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. 1802635, Aircraft - Conductors for general purpose aircraft electrical cables and aerospace applications -Dimensions and characteristics EN 2084, Aerospace s
13、eries - Cables, electric, single-core, general purpose, with conductors in copper or copper alloy - Technical specification1) EN 3475-1 00, Aerospace series - Cables, electrical, aircraft use - Test methods - Part 700: General EN 3838, Aerospace series - Requirements and tests on user-applied markin
14、gs on aircraft electrical cables EN 4434, Aerospace series - Copper or copper alloy lightweight conductors for electrical cables - Product standard ) FED-STD-595B, Colors used in government procurement2) TR 6058, Aerospace series - Cable code identification lisp) 3 Definitions and symbols See EN 347
15、5-100. 1) Published as AECMA Prestandard at the date of publication of this standard 2) Published by: General Services Administration - Federal Supply Service Bureau - Specification Section - Suite 8100 - 470 East lEnfant Plaza, SW - Washinton, DC 20407 3) Published as AECMA Technical Report at the
16、date of publication of this standard Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 4 prEN 461 1-002:2004 Number of cores Specified code 4 List of
17、product standards 1 2 3 4 5 6 7 a 9 10 A B C D E F G H J K EN 461 1-003, EN 461 1-004, EN 461 1-005, EN 461 1-006, EN 461 1-007, EN 461 1-008, EN 461 1-009, Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 003: Tin plated copper - Opera
18、ting temperatures, between - 65 “C and 135 “C - Single extruded wall for enclosed applications - UV laser printable - Product standard Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 004: Tin plated copper - Operating temperatures, bet
19、ween - 65 “C and 135 “C - Dual extruded wall for open applications, UV laser printable - Product standard Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 005: Silver plated copper- Operating temperatures, between - 65 “C and 150 “C - S
20、ingle extruded wall for enclosed applications, UV laser printable - Product standard Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 006: Silver plated copper- Operating temperatures, between - 65 “C and 150 “C - Dual extruded wall for
21、 open applications, UV laser printable - Product standard Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 007: Nickel plated copper - Operating temperatures, between - 65 “C and 150 “C - Dual extruded wall for open applications, UV las
22、er printable - Product standard Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 008: BP - Nickel plated copper - Operating temperatures, between - 65 “C and 150 “C - Dual extruded wall for open applications, with additional protection,
23、 in areas of high vibration, cable flexing and fluid contamination, UV laser printable - Product standard Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 009: BJ - Nickel plated copper - Operating temperatures, between -65 “C and 150 “
24、C - Single extruded wall for use as cable cores or within equipment, in areas of high vibration, cable flexing and fluid contamination, UV laser printable - Product standard 5 Materials and construction 5.1 Materials The cable conductors shall be made of copper or copper alloy and nickel or silver o
25、r tin-plated conforming to IS0 2635 Table 2 - conductor, electric cable, lightweight, in copper or copper alloy or as specified in the product standards. 5.2 Construction See individual product standards. 5.2.1 Number of cores See Table 1. Copyright Association Europeene des Constructeurs de Materie
26、l Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 5 prEN 461 1-002:2004 5.2.2 Unless specified by the purchaser coding shall be as follows: See Table 2. Colour coding of single core cables Table 2 - Colour code
27、 Code A B C D E F G H J K L M N P Q R S T U V W Colour a Red (2) Blue (6) Yellow (4) Green (5) White (9) Black (O) Brown (1) Orange (3) Purple (7) Grey (8) Light Red (2L) Not allocated Not allocated Not allocated Not allocated Not allocated Not allocated Not allocated Not allocated Not allocated Not
28、 allocated I a For information: International colour code Unless otherwise specified in the product standard or contract when UV markable red is specified as the cable outer insulation or jacket then light red (2L) shall be used. Light red shall be a good match to Munsell 2.5R 6.9 to 7.4 or Federal
29、Standard 595B - 31638 to 31668 or RAL 3015. 5.2.3 Colour coding of unscreened, multicore cables Unless specified by the purchaser coding shall be as follows: See Table 3. Table 3 Colours Number of cores in cables 2 3 4 5 6 7 8 9 10 Red Red Red Red Red Red Red Red Red Blue Blue Blue Blue Blue Blue Bl
30、ue Blue Blue Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Green Green Green Green Green Green Green White White White White White White Black Black Black Black Black Brown Brown Brown Brown Orange Orange Orange Purple Purple Grey I Jacket colour shall be white unless specified by the purc
31、haser. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 6 prEN 461 1-002:2004 Reference to EN standard cable 4 spaces mandatory i 6 Identification an
32、d marking The identification and marking of cables by the manufacturer shall be in accordance with EN 2084. As the designation, required for orders, is generally too long, for use in electrical drawings a shorter designation (without colour information) is given in TR 6058. Example: Designation: EN
33、461 1 -004A006P Cross reference: XLETFE 20 This shorter designation is used for identification and marking as in the following example: . i I Size code I ? I &b I Manufacturer country code I Manufacturer code Year of manufacturing EN zz C 20 ? & 55 For multicore cable with jacket, the marking shall
34、be optional on core(s) and mandatory on jacket. For multicore cable without jacket, each core shall be marked with his own designation. The cables (single core or jacketed cable) shall be capable of being printed with user-applied UV laser markings according to EN 3838. Aggressive marking techniques are not permitted. 7 See EN 2084. Tech n i cal specification Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-