1、ASD STANDARD NORME ASD ASD NORM prEN 6059-501 Edition P 1 April 2009 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATIONAvenue de Tervuren, 270 - B-1150 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 775 8131 - www.asd-stan.orgICS: Descriptors: ENGLISH VERSION Ae
2、rospace series Electrical cables, installation Protection sleeves Test methods Part 501: Voltage proof test Srie arospatiale Cbles lectriques, installation Gaines de protection Mthodes dessais Partie 501: Tenue en tension Luft- und Raumfahrt Elektrische Leitungen, Installation Schutzschluche Prfverf
3、ahren Teil 501: Spannungsfestigkeit This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically app
4、roved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examina
5、tion and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national le
6、vel by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 15 April 2009 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2009 by ASD-STAN Co
7、pyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 6059-501:2009 2 Contents Page Foreword2 1 Scope 3 2 Normative references 3 3 Dielectric test .3 Annex A (informative) Schematic drawing of the dielectric
8、equipment 4 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. Copyrig
9、ht ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 6059-501:2009 3 1 Scope This standard specifies a method of performing voltage proof tests on finished protection sleeves. It shall be used together with EN 60
10、59-100. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 6059-100, Aeros
11、pace series Electrical cables, installation Protection sleeves Test methods Part 100: General. 3 Dielectric test 3.1 Equipment The dielectric equipment is composed of an electrical generator and a test fixture. The test fixture is composed of a structure containing several rows of metallic ball chai
12、ns and a metallic mandrel. The negative pole of the electrical generator is connected to the metallic mandrel with a clip. The positive pole is connected to the metallic ball chains and the metallic frame. See a type of equipment in Annex A (informative). 3.2 Preparation of specimens The specimen an
13、d the metallic mandrel are 50 cm long. The external diameter of the metallic mandrel shall be as closed as possible to the internal diameter of the protection sleeve to test. The specimen is installed on the metallic mandrel which is connected to the negative pole of the generator. The assembly is i
14、nstalled into the chamber so that the ball chains are only in contact with the specimen and not with the mandrel. The not protected part of the metallic mandrel which allows the connection must be kept out of the chamber. 3.3 Test procedure The protection sleeve shall be subject to a voltage test at
15、 ambient temperature. The voltage specified by the technical specification with a frequency of 40 Hz to 60 Hz, shall be applied for at least 1 minute between the metallic ball chains and the mandrel. The voltage rise time shall be between 300 V per second and 500 V per second. After one minute at th
16、e value defined in the product standard, the test should be stopped. 3.4 Requirement There shall be no electrical perforation of the sleeve and no evidence of damage. Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license fro
17、m IHS-,-,-prEN 6059-501:2009 4 Annex A (informative) Schematic drawing of the dielectric equipment Key 1 Specimen under test: 400 mm 2 Metallic mandrel 3 Metallic ball chains 4 Test fixture 5 Sleeve protection 6 Electrical Generator 7 Value kV 1 6 7 5 4 3 2Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-