1、ASD Technical Report Rapport Technique ASD ASD Fachbericht TR 4633 Edition 1 October 2007 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Avenue de Tervuren, 270 - B-1150 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 763 3565 - www.asd-stan.orgICS: Descripto
2、rs: ENGLISH VERSION Aerospace series Connectors, electrical Change in design qualification Srie arospatiale Connecteurs lectriques Qualification des volutions Luft- und Raumfahrt Elektrische Rundsteckverbinder Qualifikation der Entwicklungen This Technical Report was drawn up by the Electrical Domai
3、n of ASD-STAN. The reason which led to the publication of the document as a Technical Report is explained in the foreword. Edition approved for publication 31 October 2007 Electrical Domain Copyright 2007 by ASD-STANCopyright European Association of Aerospace Industries Provided by IHS under license
4、 with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 2 TR 4633:09-2007 Contents Page Foreword2 1 Scope 3 2 Normative references3 3 Terms and definitions .3 4 Programmes of qualification tests.3 Foreword The main task of ASD Technical Committees is to pr
5、epare EN Standards, in exceptional circumstances however, the publication of Technical Report of one of the following types may be proposed: Type 1, the subject is still under technical development requiring wider exposure; Type 2, a Technical Committee has collected data of a different kind from th
6、at which is normally published as a European Standard. The Electrical Domain decided to publish this document in the form of a Technical Report of type 2 Copyright European Association of Aerospace Industries Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permit
7、ted without license from IHS-,-,-Page 3 TR 4633:09-2007 1 Scope This Technical Report is a guideline for the mandated body and the manufacturer to establish a programme of qualification tests for a change in design of parts of connectors already qualified. 2 Normative references The following refere
8、nced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2591-100*, Aerospace series Elements of electrical and optical con
9、nection Test methods General. EN 2997*, Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures 65 C to 175 C continuous, 200 C continuous, 260 C peak. EN 3372*, Aerospace series Connectors, electrical, circular, mediu
10、m and high contact density, scoop-proof with bayonet coupling, operating temperatures 65 C to 175 C or 200 C continuous. EN 3545*, Aerospace series Connectors, electrical, rectangular, with sealed and non-sealed rear, plastic housing, locking device, operating temperatures 55 C to 175 C. EN 3645*, A
11、erospace series Connectors, electrical, circular, scoop-proof, triple start threaded coupling, operating temperature 175 C or 200 C continuous. EN 3646*Aerospace series Connectors, electrical, circular, bayonet coupling, operating temperature 175 C or 200 C continuous. EN 3682*, Aerospace series Con
12、nectors, plug and receptacle, electrical, rectangular, interchangeable insert type, rack to panel, operating temperature 150 C continuous. EN 3716*, Aerospace series Connector, single-way, with triaxial interface, for transmission of digital data. EN 4067*, Aerospace series Connectors, electrical, c
13、ircular, scoop-proof, coupled by threaded ring, fire-resistant, operating temperature 260 C peak. EN 4165*, Aerospace series Connectors, electrical, rectangular, modular Operating temperature 175 C continuous. 3 Terms and definitions For the purposes of this document, the terms and definitions given
14、 in EN 2591-100 apply. 4 Programmes of qualification tests 4.1 General Program of qualification tests are test groups defined per kind of change in design of connector parts for each EN standard. They precise the sequence tests and the availability test per EN standard. The test severities and the i
15、nitial and final measurement shall be in agreement with the qualification tests in the EN Standard concerned. *Including all its parts. Copyright European Association of Aerospace Industries Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without licens
16、e from IHS-,-,-Page 4 TR 4633:09-2007 4.2 Sampling and definition of specimens The specimens shall be representative of the kind of change in design of connector parts and the sampling equivalent to the number in the qualification groups. 4.3 Qualification test groups The qualification test groups a
17、re defined per the applicability of the following kind of change in design of connector parts: Table 1: Housing; Table 2: Insert Sealing between insert and housing; Table 3: Interfacial seal and/or coupling seal; Table 4: Insert retention in housing. Table 1 Housing Tests EN 2591- Connectors Designa
18、tion No. 2997 3372 3545 3645 3646 3682 3716 4067 4165Surface treatment modification Group 1 Visual examination 101 Y Y Y Y Y Y Y Y Y Rapid change of temperature 305 Y Y Y Y Y Y Y Y Y Mating and unmating forces 408 Y Y Y Y Y Y Y Y Y Salt mist 307 Y Y Y Y Y Y Y Y Y Mating and unmating forces 408 Y Y Y
19、 Y Y Y Y Y Y Housing (shell) electrical continuity 205 Y Y Y Y Y Y Y Y Y Visual examination 101 Y Y Y Y Y Y Y Y Y Group 2 Visual examination 101 Y Y Y Y Y Y Y Y Y Rapid change of temperature 305 Y Y Y Y Y N N Y Y Mating and unmating forces 408 Y Y Y Y Y N N Y Y Mechanical endurance 406 Y Y Y Y Y N N
20、 Y Y Housing (shell) electrical continuity 205 Y Y Y Y Y N N Y Y Shielding effectiveness from 100 MHz to 1 GHz 213 Y Y Y Y Y Y Y Y Y Visual examination 101 Y Y Y Y Y Y Y Y Y continued Copyright European Association of Aerospace Industries Provided by IHS under license with AECMA Not for ResaleNo rep
21、roduction or networking permitted without license from IHS-,-,-Page 5 TR 4633:09-2007 Table 1 Housing (concluded) Tests EN 2591- Connectors Designation No. 2997 3372 3545 3645 3646 3682 3716 4067 4165Coupling system modification Group 1 Visual examination 101 Y Y Y Y Y N Y Y Y Mating and unmating fo
22、rces 408 Y Y Y Y Y N Y Y Y Mechanical endurance 406 Y Y Y Y Y N Y Y Y Sinusoidal and random vibration 403 Y Y Y Y Y N Y Y Y Shock 402 Y Y Y Y Y N Y Y Y Visual examination 101 Y Y Y Y Y N Y Y Y Group 2 Visual examination 101 Y N Y Y N N N Y Y Mating and unmating forces 408 Y N Y Y N N N Y Y Salt mist
23、 307 Y N Y Y N N N Y Y Mating and unmating forces 408 Y N Y Y N N N Y Y Visual examination 101 Y N Y Y N N N Y Y Table 2 Inserts Sealing between insert and housing Tests EN 2591- Connectors Designation No. 2997 3372 3545 3645 3646 3682 3716 4067 4165Material and/or design modification Group 1 Visual
24、 examination 101 Y Y N Y Y Y N Y Y Durability of contact retention system and seals 407 Y Y N Y Y Y N Y Y Rapid change of temperature 305 Y Y N Y Y Y N Y Y Immersion at low air pressure 314 Y Y N Y Y Y N Y Y Damp heat cyclic test 321 Y Y N Y Y Y N Y Y Measurement of insulation resistance 206 Y Y N Y
25、 Y Y N Y Y Voltage proof test 207 Y Y N Y Y Y N Y Y Visual examination 101 Y Y N Y Y Y N Y Y Group 2 Visual examination 101 Y Y N Y Y Y N Y Y Endurance at temperature (method B) 301 Y Y N Y Y Y N Y Y Contact retention in insert 409 Y Y N Y Y Y N Y Y Insert retention in housing (axial) 410 Y Y N Y Y
26、Y N Y Y Visual examination 101 Y Y N Y Y Y N Y Y continued Copyright European Association of Aerospace Industries Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 6 TR 4633:09-2007 Table 2 Inserts Sealing between insert
27、and housing (concluded) Tests EN 2591- Connectors Designation No. 2997 3372 3545 3645 3646 3682 3716 4067 4165Group 3 Visual examination 101 Y Y N Y Y Y N Y Y Fluid resistance 315 Y Y N Y Y Y N Y Y Measurement of insulation resistance 206 Y Y N Y Y Y N Y Y Voltage proof test 207 Y Y N Y Y Y N Y Y Co
28、ntact retention in insert 409 Y Y N Y Y Y N Y Y Visual examination 101 Y Y N Y Y Y N Y Y Group 4 Visual examination 101 Y Y N Y Y Y N Y Y Contact insertion and extraction forces 412 Y Y N Y Y Y N Y Y Use of tools 506 Y Y N Y Y Y N Y Y Contact retention in insert 409 Y Y N Y Y Y N Y Y Flammability (i
29、f applicable) 317 Y Y N Y Y Y N Y Y Fire-resistance (if applicable) 318 Y N N Y N N N Y N Visual examination 101 Y Y N Y Y Y N Y Y Contact retention design modification Group 1 Visual examination 101 Y Y Y Y Y Y Y Y Y Endurance at temperature (method B) 301 Y Y Y Y Y Y Y Y Y Contact retention in ins
30、ert 409 Y Y Y Y Y Y Y Y Y Visual examination 101 Y Y Y Y Y Y Y Y Y Group 2 Visual examination 101 Y Y Y Y Y Y Y Y Y Sinusoidal and random vibration 403 Y Y Y Y Y Y Y Y Y Shock 402 Y Y Y Y Y Y Y Y Y Contact retention system effectiveness 426 Y Y Y Y Y Y Y Y Y Contact retention in insert 409 Y Y Y Y Y
31、 Y Y Y Y Visual examination 101 Y Y Y Y Y Y Y Y Y Copyright European Association of Aerospace Industries Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 7 TR 4633:09-2007 Table 3 Interfacial seal and/or coupling seal Te
32、sts EN 2591- Connectors Designation No. 2997 3372 3545 3645 3646 3682 3716 4067 4165Interfacial seal modification Group 1 Visual examination 101 Y Y Y Y Y Y N Y Y Mating and unmating forces 408 Y Y Y Y Y Y N Y Y Immersion at low air pressure 314 Y Y Y Y Y Y N Y Y Measurement of insulation resistance
33、 206 Y Y Y Y Y Y N Y Y Voltage proof test 207 Y Y Y Y Y Y N Y Y Visual examination 101 Y Y Y Y Y Y N Y Y Group 2 Visual examination 101 Y Y Y Y Y Y N Y Y Mating and unmating forces 408 Y Y Y Y Y Y N Y Y Rapid change of temperature 305 Y Y Y Y Y N N Y Y Climatic sequence 302 N N N N N Y N N N Cold/lo
34、w pressure and damp heat 303 Y Y N Y N N N Y Y Mating and unmating forces 408 Y Y Y Y Y Y N Y Y Interfacial sealing 324 Y Y Y Y Y Y N Y N Measurement of insulation resistance 206 Y Y Y Y Y Y N Y Y Voltage proof test 207 Y Y Y Y Y Y N Y Y Visual examination 101 Y Y Y Y Y Y N Y Y Group 3 Visual examin
35、ation 101 Y Y Y Y Y Y N Y Y Fluid resistance 315 Y Y Y Y Y Y N Y Y Measurement of insulation resistance 206 Y Y Y Y Y Y N Y Y Voltage proof test 207 Y Y Y Y Y Y N Y Y Mating and unmating forces 408 Y Y Y Y Y Y N Y Y Visual examination 101 Y Y Y Y Y Y N Y Y Table 4 Insert retention in housing Tests E
36、N 2591- Connectors Designation No. 2997 3372 3545 3645 3646 3682 3716 4067 4165Visual examination 101 Y Y N Y Y N N Y N Mating and unmating forces 408 Y Y N Y Y N N Y N Rapid change of temperature 305 Y Y N Y Y N N Y N Insert retention in housing (axial) 410 Y Y N Y Y N N Y N Voltage proof test 207 Y Y N Y Y N N Y N Visual examination 101 Y Y N Y Y N N Y N Copyright European Association of Aerospace Industries Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-