1、 2013 Standard for Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets Approved by ANSI on October 1, 2013 ANSI/AHRI Standard 1201 (SI) Copyright 2013, by Air-Conditioning, Heating and Refrigeration Institute Registered United States Patent and Trademark Office P
2、rice $10.00 (Members) $20.00 (Non-Members) Printed in U. S.A. IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline.
3、It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines
4、 employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes ANSI/AHRI Standard 1200-2010. For I-P ratings, see ANSI/AHRI Standard 1200 (
5、I-P) 2013. i TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope .1 Section 3. Definitions .1 Section 4. Test Requirements .4 Section 5. Rating Requirements for Remote Commercial Refrigerated Display Merchandisers and Storage Cabinets .4 Section 6. Rating Requirements for Self-conta
6、ined Commercial Refrigerated Display Merchandisers and Storage Cabinets .8 Section 7. Symbols and Subscripts .9 Section 8. Minimum Data Requirements for Published Ratings 10 Section 9. Marking and Nameplate Data 10 Section 10. Conformance Conditions .10 TABLES Table 1. COP for Remote Commercial Refr
7、igerated Display Merchandisers and Storage Cabinets .6 Table 2. Presentation of Data for Remote Commercial Refrigerated Display Merchandisers and Storage Cabinets .11 Table 3. Presentation of Data for Self-contained Commercial Refrigerated Display Merchandisers and Storage Cabinets 11 ii APPENDICES
8、Appendix A. References - Normative 12 Appendix B. References - Informative.12 Appendix C. Commercial Refrigerated Display Merchandiser and Storage Cabinet Load Line Volume Calculation - Normative .13 Appendix D. Commercial Refrigerated Display Merchandiser Total Display Area (TDA) Calculation - Norm
9、ative 16 Appendix E. Example Energy Performance Representation for a Remote Commercial Refrigerated Display Merchandiser or Storage Cabinet - Informative .22 Appendix F. Example Energy Performance Representation for a Self-contained Commercial Refrigerated Display Merchandiser or Storage Cabinet - I
10、nformative 25 TABLES FOR APPENDICES Table E1. Sample Presentation of Data for Remote Commercial Refrigerated Display Merchandisers and Storage Cabinets 24 Table F1. Sample Presentation of Data for Self-contained Commercial Refrigerated Display Merchandisers and Storage Cabinets 26 FIGURES FOR APPEND
11、ICES Figure C1.1. Sample Isometric View of Commercial Refrigerated Display Merchandisers for Illustrating Length of Refrigerated Space 13 Figure C1.2. Sample Cross Sections of Commercial Refrigerated Display Merchandisers for Load Line Volume Calculation 14 Figure C2. Sample Cross Section of Commerc
12、ial Refrigerated Storage Cabinets for Volume Calculation .15 Figure D1. Vertical Open Multi-deck 16 Figure D2. Vertical Open Multi-deck with Transparent Front 16 Figure D3. Semi-vertical Open Multi-deck .17 Figure D4. Semi-vertical Open Multi-deck with Transparent Front .17 iii Figure D5. Horizontal
13、 Open Single-deck 17 Figure D6. Horizontal Open Single-deck with Transparent Front 17 Figure D7. Service Over Counter with Flat Transparent Front .18 Figure D8. Service Over Counter with Curved Transparent Front 18 Figure D9. Horizontal Open Single-deck Island .18 Figure D10. Horizontal Open Single-
14、deck Island with Transparent Walls .18 Figure D11. Horizontal Open Single-deck Island with Transparent Walls .19 Figure D12. Vertical Closed Multi-deck with Transparent Doors 19 Figure D13. Vertical End Wall with Transparent Section .19 Figure D14. Semi-vertical End Wall with Transparent Section 19
15、Figure D15. Horizontal Single-deck and Single-deck Island End Wall with Transparent Section .20 Figure D16. Service Over Counter End Wall with Transparent Section .20 Figure D17. Example TDA for Unique Geometries 20 Figure D18. Radius Cases with Transparent Sides 21 ANSI/AHRI STANDARD 1201 (SI)2013
16、1 PERFORMANCE RATING OF COMMERCIAL REFRIGERATED DISPLAY MERCHANDISERS AND STORAGE CABINETS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Commercial Refrigerated Display Merchandisers and Storage Cabinets: definitions; test requirements; rating requirements; symbols
17、 and subscripts; minimum data requirements for Published Ratings; marking and nameplate data and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. The values reported using this sta
18、ndard allow comparison of energy consumption within each of the following product categories: Remote Commercial Refrigerated Display Merchandisers, Remote Commercial Refrigerated Storage Cabinets, Self-contained Commercial Refrigerated Display Merchandisers and Self-contained Commercial Refrigerated
19、 Storage Cabinets. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to the following manufacturers standard catalog Commercial Refrigerated Display Merchandisers and Storage Cabinets, provided that
20、the cases are equipped and designed to work with electrically driven, direct expansion type systems: 2.1.1 Self-contained and Remote Commercial Refrigerated Display Merchandisers and Storage Cabinets 2.1.2 Open and Closed Commercial Refrigerated Display Merchandisers 2.2 Exclusions. This standard do
21、es not apply to the following: 2.2.1 Refrigerated vending machines 2.2.2 Ice makers 2.2.3 Soft serve extruders 2.2.4 Secondary coolant applications Section 3. Definitions All terms in this document will follow the standard industry definitions in the ASHRAE Wikipedia website (http:/wiki.ashrae.org/i
22、ndex.php/ASHRAEwiki) unless otherwise defined in this section. 3.1 Anti-condensate Energy Consumption (AEC). The Total Daily Energy Consumption used in condensate removal on the outside of the Commercial Refrigerated Display Merchandiser or Storage Cabinet, which typically includes fan and condensat
23、e heater energy expressed in kWh per day. 3.2 Calculated Daily Energy Consumption (CDEC). This is a value for Remote Commercial Refrigerated Display Merchandisers or Storage Cabinets based upon the requirements of this standard expressed in kWh per day. 3.3 Coefficient of Performance (COP). A ratio
24、of the cooling capacity in watts W to the power input value in watts W at any given set of Rating Conditions expressed in watts/watt, W/W. 3.4 Commercial Refrigerated Display Merchandiser. A cabinet cooled by a refrigerating system for displaying chilled and/or frozen food to be maintained within pr
25、escribed temperature limits. ANSI/AHRI STANDARD 1201 (SI)-2013 2 3.4.1 Closed Commercial Refrigerated Display Merchandiser. A refrigerated display merchandiser where food is accessible for removal by opening or moving doors or panels. 3.4.2 Open Commercial Refrigerated Display Merchandiser. A refrig
26、erated display merchandiser where food is accessible for removal without opening or moving doors or panels. 3.4.3 Remote Commercial Refrigerated Display Merchandiser. A refrigerated display merchandiser that has a remote condensing unit. 3.4.4 Self-contained Commercial Refrigerated Display Merchandi
27、ser. A refrigerated display merchandiser that has a completely factory assembled and factory tested refrigerating system in which all of the refrigerant-containing parts are permanently connected at the factory. 3.4.5 Service Over the Counter (SOC). A commercial refrigerator or freezer equipped with
28、 sliding or hinged doors in the back intended for use by sales personnel, and with glass or other transparent material in the front for displaying merchandise. The equipment has a height no greater than 167.6 centimeters and is intended to serve as a counter for transactions between sales personnel
29、and customers. 3.5 Commercial Refrigerated Storage Cabinet. A closed cabinet cooled by a refrigerating system for storing chilled and/or frozen food to be maintained within prescribed temperature limits. 3.5.1 Remote Commercial Refrigerated Storage Cabinet. A refrigerated storage cabinet that has a
30、remote condensing unit. 3.5.2 Self-contained Commercial Refrigerated Storage Cabinet. A refrigerated storage cabinet that has a completely factory assembled and factory tested refrigerating system in which all of the refrigerant-containing parts are permanently connected at the factory. 3.6 Compress
31、or Energy Consumption (CEC). The energy consumed by the compressor expressed in kWh per day. 3.7 Condensate Evaporator Pan Energy Consumption (PEC). The amount of heat energy required to change condensate from liquid to a vapor in the evaporator pan expressed in kWh per day. 3.8 Defrost Energy Consu
32、mption (DEC). The energy consumed during defrost cycles expressed in kWh per day. 3.9 Dew Point. Refrigerant vapor saturation temperature at a specified pressure expressed in C. 3.9.1 Adjusted Dew Point. An adjusted temperature lower than actual Dew Point temperature expressed in C, resulting from s
33、uction line pressure losses, equal to saturated suction temperature at the compressor. 3.10 Fan Energy Consumption (FEC). The energy consumed by fan motors expressed in kWh per day. 3.11 Integrated Average Temperature. The average of all test package measurements taken during the test expressed in C
34、. 3.12 Lighting Energy Consumption (LEC). The energy consumed by lighted shelves and lighting internal to the refrigerated display merchandiser or storage cabinet expressed in kWh per day. 3.13 Product Temperature. Commercial Refrigerated Display Merchandisers or Storage Cabinets shall be tested wit
35、h one or more of the following Integrated Average Temperatures: 3.13.1 Ice Cream Applications. Commercial Refrigerated Display Merchandisers and Storage Cabinets intended specifically for the storage, display or dispensing of ice cream and so labeled by the manufacturer shall have an Integrated Aver
36、age Product Temperature of -26.0C 1.1C. 3.13.2 Low Temperature Applications. Commercial Refrigerated Display Merchandisers and Storage Cabinets ANSI/AHRI STANDARD 1201 (SI)2013 3 intended for Low Temperature Applications to include storing and displaying frozen foods, as well as ice cream products,
37、shall have an Integrated Average Product Temperature of -18C 1.1C. 3.13.3 Medium Temperature Applications. Commercial Refrigerated Display Merchandisers and Storage Cabinets intended for Medium Temperature Applications, shall have an Integrated Average Temperature of 3.3C 1.1C. 3.13.4 Application Pr
38、oduct Temperature. This test allows Integrated Average Temperatures other than 3.13.1, 3.13.2 and 3.13.3. Note: Requirement 3.13.1 is defined to address products designed and labeled explicitly for Ice Cream Applications as defined in the United States Code of Federal Regulations 10 CFR Part 431 Sec
39、tion IV.B.5. Freezer display merchandisers and storage cabinets that are designed for use in both low temperature (frozen food) and Ice Cream Applications by making set point adjustments will be rated as a low temperature application (3.13.2). 3.14 Published Rating. A statement of the assigned value
40、s of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen for its application. The term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by
41、the manufacturer, at stated Rating Conditions. 3.14.1 Application Rating. A rating based on tests performed at application Rating Conditions (other than Standard Rating Conditions). 3.14.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.15 Rating Conditions. Any s
42、et of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.15.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. 3.16 “Shall“ or “Should“. “Shall“ or “should“ s
43、hall be interpreted as follows: 3.16.1 Shall. Where “shall“ or “shall not“ is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.16.2 Should. “Should“ is used to indicate provisions which are not mandatory but which are desirable as good practic
44、e. 3.17 Total Daily Energy Consumption (TDEC). A calculated energy consumption value for Self-contained Commercial Refrigerated Display Merchandisers and Storage Cabinets based upon the requirements of this standard expressed in kWh per day. 3.18 Total Display Area (TDA). The sum of the projected ar
45、ea(s) for visible product expressed in m2. 3.18.1 Transparent Surface. A transparent surface shall have a minimum of 65% light transmission or 65% clear surface. For example, silk-screened glass may or may not be transparent depending on the amount of silkscreen applied.” 3. 19 Volume. Two methods a
46、re defined for determining refrigerated volume. 3.19.1 AHAM Volume Method. The interior volume of a refrigerator as calculated by AHAM HRF-1. 3.19.2 Load Line Volume Method. The gross interior volume of the refrigerator contained within the load limit lines. This gross volume shall be calculated wit
47、hout display devices installed. ANSI/AHRI STANDARD 1201 (SI)-2013 4 Section 4. Test Requirements 4.1 Test Requirements. The tests required for this standard shall be conducted in accordance with ANSI/ASHRAE Standard 72. 4.1.1 Dry-Bulb Temperature. The average test-room dry-bulb temperatureshall be 2
48、4.0C 1.0C, when measured in accordance with ANSI/ASHRAE Standard 72. 4.1.2 Wet-Bulb Temperature. The average test-room wet-bulb temperature shall be 18.0C 1.0C, when measured in accordance with ANSI/ASHRAE Standard 72. 4.1.3 Electrical Conditions. Nameplate voltages for 60 Hertz systems are shown in
49、 Table 1 of AHRI Standard 110. Nameplate voltages for 50 Hertz systems shall include one or more of the utilization voltages shown in Table 1 of IEC Standard 60038. Tests shall be performed at the nameplate rated voltage and frequency unless otherwise specified in this standard. For all dual nameplate voltage equipment covered by this standard, tests shall be performed at both voltages or at the lower voltage if only a single rating is to be published. Section 5. Rating Requirements for Remote Commercial Refrigerated Display Merchandisers and