1、C22.2 No. 41-13Grounding and bonding equipmentLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing var
2、ied viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liabilityThi
3、s document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third
4、partys intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation. IN NO E
5、VENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAG
6、ES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS B
7、EEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to ano
8、ther person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this doc
9、ument. CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes. Intellectual property rights and ownershipAs between
10、 CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secret
11、s that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Groups and/or others int
12、ellectual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.Patent rightsAttention is drawn to t
13、he possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely
14、their own responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form:sLOADTHISDOCUMENTONTOACOMPUTERFORTHESOLEPURPOSEO
15、FREVIEWINGITsSEARCHANDBROWSETHISDOCUMENTANDsPRINTTHISDOCUMENTIFITISIN0$ relevant clause, table, and/or figure number; wording of the proposed change; and rationalefor the change.To purchase CSA Group Standards and related publications, visit CSA Groups Online Store atshop.csa.ca or call toll-free 1-
16、800-463-6727 or 416-747-4044.Copyright 2013 Underwriters Laboratories Inc.ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standardshould be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regardingthose Standards shall re
17、main the sole and exclusive property of UL.This ANSI/UL Standard for Safety consists of the Tenth edition. The most recent designation ofANSI/UL 467 as an American National Standard (ANSI) occurred on March 22, 2013. ANSI approvalfor a standard does not include the Cover Page, Transmittal Pages, Tit
18、le Page, or effective dateinformation.The Department of Defense (DoD) has adopted UL 467 on June 12, 1987. The publication of revisedpages or a new edition of this Standard will not invalidate the DoD adoption.Comments or proposals for revisions on any part of the Standard may be submitted to UL at
19、any time.Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative StandardsDevelopment System (CSDS) at http:/.To purchase UL Standards, visit Comm 2000 at http:/m- call toll-free 1-888-853-3503.CONTENTSPreface .61 Scope .82 Reference publications 83 Units of measurement 104
20、 Definitions 105 Components 116 Construction .116.1 General 116.2 Protective-type ground clamps 126.3 Strap-type clamps .136.4 Protection against corrosion 136.5 Ground clamps 146.6 Bushings .156.7 Fittings .156.8 Water-meter shunts 166.9 Armored grounding wire 166.10 Grounding electrodes .166.11 Gr
21、ound mesh 196.12 Miscellaneous devices 197 Test requirements 197.1 Wire connectors .197.2 Tightening force for ground clamps 197.3 Pull protective-type ground clamp 207.4 Grounding and bonding devices with throat liners .207.5 Short-time current .207.6 Thickness of protective coating 207.7 Rod elect
22、rodes 217.8 Coating integrity .217.9 Temperature conditioning (communications strap-type clamp) .217.10 Grounding and bonding devices for the termination of armor 218 Sampling requirements .218.1 Wire connectors .218.2 Tightening force for ground clamps 228.3 Pull protective-type ground clamp 228.4
23、Grounding and bonding devices with throat liners .228.5 Short-time current .228.6 Thickness of protective coating 228.7 Rod electrodes 228.8 Coating integrity .238.9 Temperature conditioning (communications strap-type clamp) .238.10 Grounding and bonding devices for the termination of armor 239 Test
24、 methods 239.1 Wire connectors .239.2 Tightening force for ground clamps 239.3 Pull protective-type ground clamp 249.4 Grounding and bonding devices with throat liners .249.5 Short-time current .249.6 Thickness of protective coating 259.7 Rod electrodes 27MARCH 22, 2013 NMX-J-590-ANCE CSA C22.2 NO.
25、41-13 UL 467 39.8 Coating integrity .279.9 Temperature conditioning (communications strap-type clamp) .279.10 Grounding and bonding devices for the termination of armor 2710 Marking, labeling, and packaging .27Annex A (Normative United States and Mexico only) Hospital Grounding EquipmentA.1 General
26、.37A.2 Construction .37A.2.1 Cord .37A.2.2 Field-wiring terminals and leads .37A.2.3 Grounding jacks .38A.2.4 Samples 38A.3 Performance 38A.3.1 Contact resistance .38A.3.2 Endurance 38A.3.3 Strain relief .39A.3.4 Flame resistance 39A.3.5 Dielectric voltage withstand .39A.3.6 Accelerated aging .39A.4
27、 Marking .39Annex B (informative) French translations and markings (See Clause 10.)Annex C (Normative United States only) Protector Grounding Conductor For Use inCommunications CircuitsINTRODUCTIONC.1 Scope 41CONSTRUCTIONC.2 Conductors 41C.3 Covering 41C.4 Marking .42C.4.1 General 42C.4.2 Month and
28、year of manufacture .43C.4.3 Multiple manufacturing locations .43PERFORMANCEC.5 Physical properties .43C.6 Flammability .43MARCH 22, 2013NMX-J-590-ANCE CSA C22.2 NO. 41-13 UL 4674Annex D Normative Exothermic Welding Connection Systems (Normative)INTRODUCTIOND.1 Scope 44CONSTRUCTIOND.2 General .44D.3
29、 Markings 44D.4 Installation instructions .44PERFORMANCED.5 Short-time current 45D.6 Mechanical sequence 45MARCH 22, 2013 NMX-J-590-ANCE CSA C22.2 NO. 41-13 UL 467 5PrefaceThis is the harmonized ANCE, CSA Group, and UL Standard for Grounding and Bonding Equipment. It isthe first edition of NMX-J-590
30、-ANCE, the sixth edition of CSA C22.2 No. 41, and the tenth edition of UL467. This edition of CSA C22.2 No. 41 supersedes the previous edition published in 2007. This edition ofUL 467 supersedes the previous edition published in 2007.This harmonized standard was prepared by the Association of Standa
31、rdization and Certification (ANCE),the CSA Group, and Underwriters Laboratories Inc. (UL). The efforts and support of the TechnicalHarmonization Committee for Connectors, of the Council on the Harmonization of ElectrotechnicalStandards of the Nations of the Americas (CANENA), are gratefully acknowle
32、dged.This Standard is considered suitable for use for conformity assessment within the stated scope of theStandard.This standard was reviewed by the CSA Integrated Committee on Electrical Connectors, under thejurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steeri
33、ngCommittee on Requirements for Electrical Safety, and has been formally approved by the CSA TechnicalCommittee.This standard has been approved by the American National Standards Institute (ANSI) as an AmericanNational Standard.Where reference is made to a specific number of samples to be tested, th
34、e specified number is to beconsidered a minimum quantity.Note: Althoughtheintendedprimaryapplicationofthisstandardisstatedinitsscope,itisimportanttonotethatitremainsthe responsibility of the users of the standard to judge its suitability for their particular purpose.Level of harmonizationThisstandar
35、dusestheIECformatbutisnotbasedon,norisitconsideredequivalentto,anIECstandard.This standard is published as an equivalent standard for ANCE, CSA Group and UL.Anequivalentstandardisastandardthatissubstantiallythesameintechnicalcontent,exceptasfollows:Technical national differences are allowed for code
36、s and governmental regulations as well as thoserecognizedasbeinginaccordancewithNAFTAArticle905,forexample,becauseoffundamentalclimatic,geographical, technological, or infrastructural factors, scientific justification or the level of protection thatthe country considers appropriate. Presentation is
37、word for word except for editorial changes.Reasons for differences from IECThe Technical Harmonization Committee identified one IEC standard, IEC 60364-5-54, that addressesgrounding and bonding equipment included in the scope of this Standard, Electrical installations ofbuildings Part 5-54: Selectio
38、n and erection of electrical equipment Earthing arrangements, protectiveconductors and protective bonding conductors. This standard addresses the earthing arrangements,protectiveconductors,andprotectivebondingconductorsinordertosatisfythesafetyrequirementsoftheelectrical installation. It has the sta
39、tus of a basic safety publication in accordance with IEC Guide 104.MARCH 22, 2013NMX-J-590-ANCE CSA C22.2 NO. 41-13 UL 4676The IEC standards for grounding and bonding equipment are recognized as being generally systemspecific. The THC determined that the safe use of grounding and bonding equipment i
40、s dependent on thedesign and performance of the grounding and bonding equipment in relation to the North Americanelectrical codes with which they are intended to be installed.InterpretationsThe interpretation by the standards development organization of an identical or equivalent standard isbased on
41、 the literal text to determine compliance with the standard in accordance with the proceduralrules of the standards development organization. If more than one interpretation of the literal text has beenidentified, a revision is to be proposed as soon as possible to each of the standards developmento
42、rganizations to more accurately reflect the intent.ANCE effective dateThe effective date for ANCE will be announced through the Diario Oficial de la Federacin (OfficialGazette) and is indicated on the cover page.CSA Group effective dateThe effective date for CSA Group will be announced through CSA I
43、nforms or a CSA Group certificationnotice.UL effective dateAs of March 22, 2013, all products Listed or Recognized by UL must comply with the requirements in thisstandard except for annexes in the following list, which are effective March 22, 2016.Annex C and Annex DA UL effective date is one establ
44、ished by Underwriters Laboratories Inc. and is not part of the ANSIapproved standard.MARCH 22, 2013 NMX-J-590-ANCE CSA C22.2 NO. 41-13 UL 467 71 Scope1.1 This Standard applies to grounding and bonding equipment for use in accordance with the CanadianElectrical Code, Part I, CSA C22.1, in Canada, the
45、 National Electrical Code, NFPA 70, in the UnitedStates, or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico.1.2 This Standard applies to the following grounding and bonding equipment:a) ground clamps, bonding devices, grounding bushings, water-meter shunts, groundingelectrodes, an
46、d the like used in a grounding system;b) equipment for making electrical connections betweeni) the grounding conductors used in electrical power systems, non-current-carryingmetal parts of electrical equipment, armored grounding wires, metal raceways, and thelike; andii) grounding electrodes;c) equi
47、pment for making electrical connections betweeni) the grounding conductors used in telecommunications systems such as telephone,radio, CATV, network power broadband, and the like; andii) grounding electrodes;d) hospital grounding jacks and mating grounding cord assemblies (for Mexico and the UnitedS
48、tates, see Annex A);e) bonding devices for making electrical connections betweeni) the hex head of a brass fitting used in a piping system in accordance with 250.104 ofNFPA 70; andii) the grounding electrodes; andf) intersystem bonding terminations for connecting intersystem bonding and groundingcon
49、ductors for other systems in accordance with NFPA 70.Notes:1) In Canada, “hospital grounding jacks” are not defined in CSA C22.1, Canadian Electrical Code, Part I.2) In Canada, mating ground cord assemblies are covered in CSA C22.2 No. 21 and CSA C22.2 No. 42.2 Reference publicationsFor undated references to S