ImageVerifierCode 换一换
格式:PDF , 页数:17 ,大小:165.35KB ,
资源ID:434738      下载积分:5000 积分
快捷下载
登录下载
邮箱/手机:
温馨提示:
如需开发票,请勿充值!快捷下载时,用户名和密码都是您填写的邮箱或者手机号,方便查询和重复下载(系统自动生成)。
如填写123,账号就是123,密码也是123。
特别说明:
请自助下载,系统不会自动发送文件的哦; 如果您已付费,想二次下载,请登录后访问:我的下载记录
支付方式: 支付宝扫码支付 微信扫码支付   
注意:如需开发票,请勿充值!
验证码:   换一换

加入VIP,免费下载
 

温馨提示:由于个人手机设置不同,如果发现不能下载,请复制以下地址【http://www.mydoc123.com/d-434738.html】到电脑端继续下载(重复下载不扣费)。

已注册用户请登录:
账号:
密码:
验证码:   换一换
  忘记密码?
三方登录: 微信登录  

下载须知

1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。
2: 试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。
3: 文件的所有权益归上传用户所有。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 本站仅提供交流平台,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

版权提示 | 免责声明

本文(ANSI ESTA E1.3-2001 Entertainment Technology Lighting Control Systems 0 to 10V Analog Control Specification (Formerly PLASA E1.3).pdf)为本站会员(eastlab115)主动上传,麦多课文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知麦多课文库(发送邮件至master@mydoc123.com或直接QQ联系客服),我们立即给予删除!

ANSI ESTA E1.3-2001 Entertainment Technology Lighting Control Systems 0 to 10V Analog Control Specification (Formerly PLASA E1.3).pdf

1、ANSI E1.3 - 2001 (R2011)Entertainment TechnologyLighting Control Systems0 to 10 V Analog Control SpecificationCP/1997-1003r11blank pageANSI E1.3 - 2001 (R2011)Entertainment TechnologyLighting Control Systems0 to 10 V Analog Control SpecificationCopyright 2011 PLASA NA. All rights reserved.CP/1997-10

2、03r11Approved as an American National Standard by the ANSI Board of Standards Review on 28 June 2011.This document is a reaffirmation without substantive changes of ANSI E1.3 - 2001.Notice and DisclaimerPLASA does not approve, inspect, or certify any installations, procedures, equipment or materials

3、 for compliance with codes, recommended practices or standards. Compliance with an PLASA standard or recommended practice is the sole and exclusive responsibility of the manufacturer or provider and is entirely within their control and discretion. Any markings, identification, or other claims of com

4、pliance do not constitute certification or approval of any type or nature whatsoever by PLASA.PLASA neither guarantees nor warrants the accuracy or completeness of any information published herein and disclaim liability for any personal injury, property or other damage or injury of any nature whatso

5、ever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on this document. In issuing and distributing this document, PLASA does not either (a) undertake to render professional or other services for or on behalf of any

6、 person or entity, or (b) undertake any duty to any person or entity with respect to this document or its contents. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable

7、care in any given circumstance. ANSI E1.3 - 2001 (R2011), Entertainment Technology Lighting Control Systems 0 to 10 V Analog Control Specifiation 2011 PLASA North America CP/1997- 1003r11Published By:PLASA North America630 Ninth Avenue, Suite 609New York, NY 10036USAPhone: 1-212-244-1505Fax: 1-212-2

8、44-1502Email: standards.naplasa.orgFor additional copies of this document contact:The ESTA Foundation630 Ninth Avenue, Suite 609New York, NY 10036USAPhone: 1-212-244-1505Fax: 1-212-244-1502http:/www.estafoundation.orgThe PLASA Technical Standards ProgramThe PLASA Technical Standards Program was crea

9、ted to serve the PLASA membership and the entertainment industry in technical standards related matters. The goal of the Program is to take a leading role regarding technology within the entertainment industry by creating recommended practices and standards, monitoring standards issues around the wo

10、rld on behalf of our members, and improving communications and safety within the industry. PLASA works closely with the technical standards efforts of other organizations within our industry, including USITT and VPLT, as well as representing the interests of PLASA members to ANSI, UL, and the NFPA.

11、The Technical Standards Program is accredited by the American National Standards Institute.The Technical Standards Council (TSC) was established to oversee and coordinate the Technical Standards Program. Made up of individuals experienced in standards-making work from throughout our industry, the Co

12、uncil approves all projects undertaken and assigns them to the appropriate working group. The Technical Standards Council employs a Technical Standards Manager to coordinate the work of the Council and its working groups as well as maintain a “Standards Watch” on behalf of members. Working groups in

13、clude: Camera Cranes, Control Protocols, Electrical Power, Floors, Fog and Smoke, Followspot Position, Photometrics, Rigging, and Stage Lifts.PLASA encourages active participation in the Technical Standards Program. There are several ways to become involved. If you would like to become a member of a

14、n existing working group, as have over four hundred people, you must complete an application which is available from the PLASA office. Your application is subject to approval by the working group and you will be required to actively participate in the work of the group. This includes responding to l

15、etter ballots and attending meetings. Membership in PLASA is not a requirement. You can also become involved by requesting that the TSC develop a standard or a recommended practice in an area of concern to you.The Control Protocols Working Group, which authored this Standard, consists of a cross sec

16、tion of entertainment industry professionals representing a diversity of interests. PLASA is committed to developing consensus-based standards and recommended practices in an open setting. ANSI E1.3 - 2001 (R2011), Entertainment Technology Lighting Control Systems 0 to 10 V Analog Control Specifiati

17、on 2011 PLASA North America CP/1997- 1003r11Table of Contents1 Scope42 History43 Purpose.44 Applicability45 Terminology and use.55.1 General.55.2 Zero55.3 Full55.4 Scale56 Electrical specifications56.1 Transmitter specifications.56.1.1 Amplitude (Transmitter).56.1.2 Current source capacity and outpu

18、t impedance (Transmitter).66.1.3 Diode protection66.2 Receiver specifications.66.2.1 Amplitude (Receiver).66.2.2 Input impedance (Receiver)76.2.3 Input filtering76.3 Short circuit protection76.4 Isolation77 Cabling.87.1 Cable length.87.1.1 Channel conductors87.1.2 Common conductor.88 Connectors89 Ma

19、rkings9Contact Information10Acknowledgments.11ANSI E1.3 - 2001 (R2011), Entertainment Technology Lighting Control Systems 0 to 10 V Analog Control Specifiation 2011 PLASA North America CP/1997- 1003r111 ScopeThis standard describes a method of controlling equipment by means of an analog control volt

20、age. It is primarily intended for lighting control equipment (controllers and dimmers) although any equipment which might be controlled by a lighting controller (intelligent lighting, strobe lights, fog machines, etc.) could use this control method.Some 0 to 10 V controlled devices (such as dimmable

21、 fluorescent ballasts) require current-sink controllers. E1.3 controllers are current-source devices and cannot control these receivers without modification or additional interface components. This standard does not address electro-magnetic compatibility (EMC) issues, which might result from control

22、 line oscillations caused by poorly designed controllers or cabling practices.2 HistoryPrior to digital and analog multiplex control systems, most remote control of lighting dimmers was done using a wire-per-dimmer system. Each dimmer had a dedicated control wire (or pair of wires). The output volta

23、ge of the dimmer was proportional to the signal on the control wire. Some of these wire-per-dimmer systems required that the control voltage be the same frequency and in phase with the dimmers AC output. Some systems used high voltage control signals. Some systems used low voltage direct current con

24、trol signals.The safety and flexibility of the low voltage DC control system gradually made it the system of choice. Many different low voltage systems were used. Some common control signals were 0 to 10 V, 0 to 15 V, 0 to 24 V, 0 to 28 V. In most cases zero volts was considered “off.“ Negative cont

25、rol voltages were also common: 0 to -10 V, 0 to -15 V, 0 to -28 V. Again in most cases zero volts was off. Some control signals used a voltage other than zero for off; for example 2 to 7.6 V and 2 to 10.5 V. In these, the lower voltage was typically “off.“Over time the 0 to 10 V control system becam

26、e the most popular. As of the writing of this specification, 0 to 10 V control systems are popular not only in lighting but for motor control and industrial automation as well. Many digital to analog converters have a standard 0 to 10 V setting. The 0 to 10 V control system is easy to convert to per

27、centage (add a zero), is easy to implement using operational amplifiers and consumer circuits, is a low enough voltage to be safe and is a high enough voltage to avoid most noise problems.3 PurposeThe purpose of this specification is to document the now common 0 to 10 V direct current control system

28、 as typically used in lighting applications and provide specifications for new designs.4 ApplicabilityThis specification is intended for the use of: System specifiers who wish to insure that the equipment they specify meets an industry standard control system. Equipment manufacturers seeking to adop

29、t an industry standard control system for basic controller/receiver interfacing. Lighting technicians who wish to understand and troubleshoot analog control systems.Adoption of this standard is strictly voluntary. It is not intended as a replacement for existing protocols already in use, but as an a

30、ddition to existing protocols and a basis for future products. The goal is to broaden the installed base of controllers, dimmers and other equipment that can communicate with each other.ANSI E1.3 - 2001 (R2011), Entertainment Technology Lighting Control Systems 0 to 10 V Analog Control Specifiation

31、2011 PLASA North America CP/1997- 1003r115 Terminology and use5.1 GeneralThis specification does not require adherence to any particular level of performance. The guidelines presented here are intended to show typical uses of 0 to 10 V control.5.2 ZeroWhen a controller is sending a level of “zero“ i

32、t shall set its control voltage to within the levels defined as “zero” in section 6.1.1. When a dimmer, or other receiving device, has a “zero“ control signal (see section 6.2.1 for voltage limits) it shall be at its minimum state. In the case of motion control, the receiver shall position itself at

33、 one extreme. In the case of speed or rate control, the receiver shall set speed to minimum or stopped.This specification does not define the minimum level, position extreme, or minimum rate. These are performance criteria left up to the users and manufacturers. In the case of dimmers, minimum may b

34、e some idle voltage or may be completely off. In the case of motion control, “zero“ may be fully clockwise, fully counter-clockwise, fully up, or fully down. In the case of a rate control it may be minimum rate or completely stopped. In the case of audio volume it could be off or maximum attenuation

35、.Note that when a console or other transmitting device is powered down or disconnected, it does not send any voltage to the receivers. The “zero“ condition of a receiver shall always be in a state which is acceptable in a default/off situation. 5.3 FullWhen a controller is sending a level of “full“

36、it shall set its control voltage to within the levels defined as “full” in section 6.1.1. When a dimmer, or other receiving device, has a “full“ control signal (see section 6.2.1 for voltage limits) it shall be at its maximum state. In the case of motion control, the receiver should position itself

37、at the opposite extreme from “zero.“ A rate or speed control should go to its fastest speed.This specification does not define the maximum level, extreme, or rate. These are performance criteria left up to the users and manufacturers.5.4 ScaleThe 0 to 10 V control is intended to be linear (as oppose

38、d to logarithmic). It is generally intended that “zero“ be represented by about 0 volts, “full“ be represented by about 10 volts, and midway between “zero“ and “full“ be represented by about 5 volts. Since this specification does not require any specific performance between “zero“ and “full“ there i

39、s no guarantee that these voltages will be met.The response of the receiving device to control input shall be specified in the manufacturers literature. This documentation can be in the form of a table, graph, or other appropriate format.6 Electrical specifications6.1 Transmitter specifications6.1.1

40、 Amplitude (Transmitter)The output of the controller shall be a steady DC. When the control level is constant, the output shall not change by more than +/- 20 mV. The output is intended to vary between 0 and 10 volts. Zero volts shall represent the full off condition and ten volts shall represent th

41、e full on condition. The output voltage shall never be less than -0.2 volts nor more than +12.0 volts with respect to signal common.To allow for variations in manufacturing tolerances the minimum and maximum control voltages may vary as shown in the table below:ANSI E1.3 - 2001 (R2011), Entertainmen

42、t Technology Lighting Control Systems 0 to 10 V Analog Control Specifiation 2011 PLASA North America CP/1997- 1003r11Condition: Minimum: Maximum:Console output at “zero,“ with a load resistance of 100,000 ohms -0.2 volts 0.2 voltsConsole output at “full,“ with a load resistance of 20,000 ohms 10.0 v

43、olts 12.0 voltsIf the controller is capable of varying the maximum or minimum output voltage, then the manufacturers specifications shall state the range of adjustment. Controllers shall be shipped adjusted for 0 to 10 V operation in accordance with this standard. Controllers not adjusted for 0 to 1

44、0 V operation in accordance with this standard shall not be marked “E1.3, 0 to 10 V Analog Control Specification.“ Any printing on the console referring to the E1.3 specification shall be covered with a label that shows the adjusted voltage range. For example:“Outputs adjusted for 0 to 15 volt opera

45、tion“6.1.2 Current source capacity and output impedance (Transmitter)Controllers or output devices should have a low output impedance to minimize loading effects. Passive controllers, with unbuffered outputs, shall use potentiometers with a resistance value of 10K ohms or less (which yields an outpu

46、t impedance of 2.5K ohms or less). Active controllers with buffered outputs shall have a source impedance of 100 ohms or less and be capable of continuously sourcing at least 2.0 milliamperes without dropping below 10 V. Controllers or output devices shall have a sinking impedance greater than 50K o

47、hms, even when power is removed.The more current source capacity a controller has the more receivers it can drive. (More is better). The manufacturers specifications shall state the output capability as both the maximum source current and the lowest load impedance at which an output of 10.0 volts ca

48、n be maintained.6.1.3 Diode protectionControllers and output devices shall be provided with a blocking diode (or equivalent circuit) such that each output presents an open circuit (50K ohms or more) to any source of voltage more positive than itself. The operation of the product shall be unaffected

49、by the presence of such a more positive voltage. This diode or equivalent circuit shall be capable of blocking voltages of +30 D.C. volts or greater.The blocking diodes allow multiple controllers or output devices to be paralleled to control the same dimmers or receiving devices. Whichever controller has the higher control voltage has control of that channel. This method of control is commonly referred to as “highest takes precedence“ or “pile-on.“6.2 Receiver specifications6.2.1 Amplitude (Receiver)The dimmer or other receiving device shall be at

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1