1、 INCITS/ISO/IEC 29109-10:2010 2011 ISO/IEC 29109-10:2010 Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 10: Hand geometry silhouette data INCITS/ISO/IEC 29109-10:2010 2011 PDF disclaimer This PDF file may contain embedded t
2、ypefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not in
3、fringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were o
4、ptimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. Adopted by INCITS (InterNational Committee for Informatio
5、n Technology Standards) as an American National Standard. Date of ANSI Approval: 8/17/2011 Published by American National Standards Institute, 25 West 43rd Street, New York, New York 10036 Copyright 2011 by Information Technology Industry Council (ITI). All rights reserved. These materials are subje
6、ct to copyright claims of International Standardization Organization (ISO), International Electrotechnical Commission (IEC), American National Standards Institute (ANSI), and Information Technology Industry Council (ITI). Not for resale. No part of this publication may be reproduced in any form, inc
7、luding an electronic retrieval system, without the prior written permission of ITI. All requests pertaining to this standard should be submitted to ITI, 1250 Eye Street NW, Washington, DC 20005. Printed in the United States of America ii ITIC 2011 All rights reserved ISO/IEC 29109-10:2010(E) ISO/IEC
8、 2010 All rights reserved iiiContents Page Foreword iv Introduction.v 1 Scope1 2 Conformance .1 3 Normative references2 4 Terms and definitions .2 5 Symbols and abbreviated terms 3 6 Conformance testing methodology.3 Annex A (informative) Guidance for Level 3B testing.10 ISO/IEC 29109-10:2010(E) iv
9、ISO/IEC 2010 All rights reservedForeword ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) form the specialized system for worldwide standardization. National bodies that are members of ISO or IEC participate in the development of Intern
10、ational Standards through technical committees established by the respective organization to deal with particular fields of technical activity. ISO and IEC technical committees collaborate in fields of mutual interest. Other international organizations, governmental and non-governmental, in liaison
11、with ISO and IEC, also take part in the work. In the field of information technology, ISO and IEC have established a joint technical committee, ISO/IEC JTC 1. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of the joint technica
12、l committee is to prepare International Standards. Draft International Standards adopted by the joint technical committee are circulated to national bodies for voting. Publication as an International Standard requires approval by at least 75 % of the national bodies casting a vote. Attention is draw
13、n to the possibility that some of the elements of this document may be the subject of patent rights. ISO and IEC shall not be held responsible for identifying any or all such patent rights. ISO/IEC 29109 consists of the following parts, under the general title Information technology Conformance test
14、ing methodology for biometric data interchange formats defined in ISO/IEC 19794: Part 1: Generalized conformance testing methodology Part 2: Finger minutiae data Part 4: Finger image data Part 5: Face image data Part 6: Iris image data Part 8: Finger pattern skeletal data Part 9: Vascular image data
15、 Part 10: Hand geometry silhouette data The following parts are under preparation: Part 7: Signature/sign time series data Part 14: DNA data ISO/IEC 29109-10:2010(E) ISO/IEC 2010 All rights reserved vIntroduction ISO/IEC 19794-10:2007 specifies a data record interchange format for recording, storing
16、, and transmitting one or more hand geometry silhouette records. This part of ISO/IEC 29109 establishes tests for checking the correctness of the binary record. The objective of ISO/IEC 19794-10:2007 cannot be completely achieved until biometric products can be tested to determine whether they confo
17、rm to those specifications. Conforming implementations are a necessary prerequisite for achieving interoperability among implementations; therefore there is a need for a standardized conformance testing methodology, test assertions, and test procedures as applicable to specific modalities addressed
18、by each part of ISO/IEC 19794. The test assertions will cover as much as practical of the ISO/IEC 19794 requirements (covering the most critical features), so that the conformity results produced by the test suites will reflect the real degree of conformity of the implementations to ISO/IEC 19794 Da
19、ta Interchange Format records. This is the motivation for the development of this conformance testing methodology. This part of ISO/IEC 29109 supports those applications that require use of hand geometry silhouette data according to ISO/IEC 19794-10:2007. It defines a testing methodology to ensure c
20、onformance of a vendors application or service to ISO/IEC 19794-10:2007. Thus this part of ISO/IEC 29109 is intended to: establish elements of the Conformance Testing Methodology framework that are specific to the Hand Geometry Silhouette-based Data Record requirements of ISO/IEC 19794-10:2007 confo
21、rmance testing, define requirements and guidelines for specifying confor mance test suites and related test methods for measuring conformity of products and services to the Hand Geometry Silhouette Data Record requirements of ISO/IEC 19794-10:2007, and define testing and reporting procedures to be f
22、ollo wed before, during, and after conformance testing. This part of ISO/IEC 29109 is applicable to the development and use of conformity test method specifications, conformity test suites for ISO/IEC 19794-10:2007 records, and conformance testing programs for ISO/IEC 19794-10:2007 conformant produc
23、ts. It is intended primarily for use by testing organizations, but may be applied by developers and users of test method specifications and test method implementations. The table of assertions in Clause 6 specifies levels of testing for the conformance requirements of ISO/IEC 19794-10:2007. INTERNAT
24、IONAL STANDARD ISO/IEC 29109-10:2010(E) ISO/IEC 2010 All rights reserved 1Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 10: Hand geometry silhouette data 1 Scope This part of ISO/IEC 29109 specifies elements of conformance
25、 testing methodology, test assertions, and test procedures as applicable to ISO/IEC 19794-10. This part of ISO/IEC 29109 establishes test assertions of the struct ure of the hand geometry silhouette data format as specified in ISO/IEC 19794-10:2007 (Type A Level 1 as defined in ISO/IEC 29109-1:2009)
26、, test assertions of internal consistency by checking the types of values that may be contained within each field (Type A Level 2 as defined in ISO/IEC 29109-1:2009), informative guidance for testing the consistency of selected encoded data fields with the input biometric data (Type B Level 3 as def
27、ined in ISO/IEC 29109-1:2009). This part of ISO/IEC 29109 does not establish test of conformance of CBEFF stru ctures required by ISO/IEC 19794-10:2007, test of consistency with input biometric data record (Level 3 as defined in ISO/IEC 29109-1:2009), test of other characteristics of biometric produ
28、cts or other types of testing of biometric products (e.g. acceptance, performance, robustness, security), test of conformance of systems that do not produce ISO/IEC 19794-10:2007 records. 2 Conformance Biometric data interchange format Conformance Test Suites (CTS) conform to this part of ISO/IEC 29
29、109 if they satisfy all of the normative requirements related to Clause 6. Additionally, implementations of Level 1 or Level 2 tests shall use the assertions defined in Table 2 and fill out an Implementation Conformance Statement (ICS) based on Table 1. Implementations of ISO/IEC 19794-10:2007 teste
30、d according to the methodology specified shall be able to claim conformance only to those Biometric Data Record (BDR) requirements specified in ISO/IEC 19794-10:2007 that are tested by the test methods established by this methodology. ISO/IEC 29109-10:2010(E) 2 ISO/IEC 2010 All rights reservedImplem
31、entations of ISO/IEC 19794-10:2007 do not necessarily need to conform to all possible aspects of ISO/IEC 19794-10:2007, but only to those ISO/IEC 19794-10:2007 requirements that are claimed to be supported by the implementation in an Implementation Conformance Statement, filled out in accordance wit
32、h Clause 8 of ISO/IEC 29109-1:2009 and Table 1 of this part of ISO/IEC 29109. A system does not need to be capable of using biometric data records that cover all possible aspects of ISO/IEC 19794-10:2007, but only those that are claimed to be supported by the system in an Implementation Conformance
33、Statement, filled out using the template provided in A.2. NOTE Level 3 and higher are not tested. 3 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest
34、 edition of the referenced document (including any amendments) applies. ISO/IEC 19794-10:2007, Information technology Biometric data interchange formats Part 10: Hand geometry silhouette data ISO/IEC 29109-1:2009, Information technology Conformance testing methodology for biometric data interchange
35、formats defined in ISO/IEC 19794 Part 1: Generalized conformance testing methodology 4 Terms and definitions For the purposes of this document, the following terms and definitions apply. 4.1 biometric data interchange record BDIR data package containing biometric data that claims to be in the form p
36、rescribed by a base standard ISO/IEC 29109-1 4.2 Freeman Chain Code FCC compact method for representing the contours of an object NOTE First made popular by Herbert Freeman. ISO/IEC 19794-10 4.3 hand geometry view record HGVR block of data that contains a hand silhouette captured from one camera poi
37、nt of view during one hand placement NOTE The block contains metadata, silhouette data, and optional extended data. ISO/IEC 19794-10 4.4 implementation under test IUT that which implements the base standard being tested ISO/IEC 29109-10:2010(E) ISO/IEC 2010 All rights reserved 3NOTE Depending on the
38、 conformance requirements of the base standard, this may simply be a set of biometric data interchange records or it may be a computer algorithm in the form of an implementation under test that creates the BDIR and/or uses the data contained in the BDIR. ISO/IEC 29109-1 5 Symbols and abbreviated ter
39、ms For the purposes of this document, the symbols and abbreviated terms given in ISO/IEC 29109-1 apply. 6 Conformance testing methodology The testing methodology specified in Clauses 6, 7 and 8 of ISO/IEC 29109-1:2009 shall apply. The content of the tables below is based on the conformance testing m
40、ethodology outlined in ISO/IEC 29109-1:2009 and shall only be used in the context of that testing methodology. Table 1 Requirements of ISO/IEC 19794-10:2007 Require-ment ID Reference in base standard Requirement Summary LevelStatus (see note) IUT Support Supported Range Test ResultR-1 Forward ISO sh
41、all not be held responsible for identifying any or all such patent rights. 3C O-1 N/A N/A R-2 5.2 To conserve space, the hand silhouette shall be recorded using a Freeman Chain Code (FCC). 2 M N/A R-3 5.2.1 Each element of the FCC shall be stored immediately following its predecessor, without regard
42、 to byte boundaries. 2 M N/A R-4 5.2.1 If necessary, the silhouette shall be padded with trailing zeros to ensure that the BDB is an integral number of octets. 2 M N/A R-5 5.2.1 Silhouette data contained in BDBs conforming to this part of ISO/IEC 19794 (see clause 2) shall be body centric. 3B M N/A
43、R-6 5.3 The BDB format specified in this part of ISO/IEC 19794 shall be embedded in a CBEFF-compliant Biometric Information Record (BIR) according to ISO/IEC 19785-1. 3C O-1 N/A N/A R-7 5.3 The CBEFF Format Owner identifier assigned by the CBEFF Registration Authority to ISO/IEC JTC 1/SC 37 shall be
44、 used in This is the sixteen-bit value 0x0101 (hexadecimal 101 or decimal 257). 3C O-1 N/A N/A R-8 5.3 The sixteen-bit CBEFF Type Code 0x0018 (hexadecimal 18 or decimal 24) shall be used for data records specified in this part of 19794. 3C O-1 N/A N/A R-9 6.1 after data acquisition and processing, e
45、ach silhouette shall have the orientation shown in Figure 3a for top-view images, or Figure 3b for side-view images. 3B M N/A ISO/IEC 29109-10:2010(E) 4 ISO/IEC 2010 All rights reservedTable 1 (continued) Require-ment ID Reference in base standard Requirement Summary LevelStatus(see note) IUT Suppor
46、t Supported Range Test ResultR-10 6.2 The silhouette shall represent either the left or right hand and shall be presented in one of the orientations depicted in Figures 3a and 3b. 3B M N/A R-11 6.2 Silhouettes taken from a left hand pinned platen shall be flipped (mirror image) to match the form of
47、Figure 3a. 3B M N/A R-12 6.3 The aspect ratio shall be 1:1, within a tolerance of 2 %. 3B M N/A R-13 6.4 The starting point shall be in the rightmost column of the silhouette in Figure 1, at the uppermost row occupied by the silhouette in that column. 2 M N/A R-14 6.4 Successive points shall trace t
48、he outline in a counterclockwise direction. 2 M N/A R-15 6.4 The silhouette shall be a closed shape (i.e., it shall have no gaps in the outline, and the final outline point shall be collocated with the starting point). 2 M N/A R-16 6.4 The starting point shall occur exactly twice in the silhouette,
49、as the first and last points only (the silhouette will not cross through the starting point at any other time). 2 M N/A R-17 6.4 The right column shall be vertical (i.e., the penultimate point shall occur directly below the starting point, and no points occur to the right of the starting point). 2 M N/A R-18 6.5 The platen shall form a right angle with the side-view reference plan
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1