1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C78.1460-2004 (R2015)Electric Lamps Single-Ended Tungsten-Halogen Lamps GZ9.5 Base, T6 Bulb, 36.5mm LCL, 76.2mm MOL with Proximity Reflector 2015 National Electrical Manufacturers Association C78.1460-2004 (R2015) American N
2、ational Standard for Electric Lamps Single-Ended Tungsten-Halogen Lamps GZ9.5 Base, T6 Bulb, 36.5mm LCL, 76.2mm MOL with Proximity Reflector Secretariat: National Electrical Manufacturers Association Approved: November 20, 2015 American National Standards Institute, Inc. C78.1460-2004 (R2015) Page 2
3、 2015 National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that th
4、ere is unanimous agreement among every person participating in the development of this document. ANSI standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteer
5、s and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or comple
6、teness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly
7、resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document
8、 will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render profess
9、ional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in
10、 determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no p
11、ower, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health- or safety-related information
12、 in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. C78.1460-2004 (R2015) Page i 2015 National Electrical Manufacturers Association AMERICAN NATIONAL STANDARD Approval of an American National Standard requires verification
13、by the American National Standards Institute, Inc. (ANSI) that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. An American National Standard implies a consensus of those substantially concerned with its scope and provisions. Cons
14、ensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly, and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and
15、objections be considered, and that a concerted effort be made toward their resolution. The existence of an American National Standard does not in any respect preclude anyone, whether s/he has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or pr
16、ocedures not conforming to the standards. It is intended as a guide to aid the manufacturer, the consumer, and the general public. ANSI does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or author
17、ity to issue an interpretation of an American National Standard in the name of the ANSI. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on this title page. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The
18、procedures of ANSI require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing ANSI. Published by National Electrical Manufacturers Association 1300 North 17
19、th Street, Suite 900 Rosslyn, Virginia 22209 2015 National Electrical Manufacturers Association All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and
20、 Pan American copyright conventions. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written permission of the publisher. Printed in the United States of America C78.1460-2004 (R2015) Page ii 2015 National Electrical Manufactur
21、ers Association Foreword (This foreword is not part of American National Standard C78.1460-2004) Suggestions for improvement of this standard should be submitted to: Secretariat C78 National Electrical Manufacturers Association 1300 North 17th Street, Suite 900 Rosslyn, Virginia 22209 This standard
22、was processed and approved by Accredited Standards Committee on Electric Lamps, C78, and its Sub-Committee, C78 WG 01. Committee approval of the standard does not necessarily imply that all committee members voted for that approval. C78.1460-2004 (R2015) Page iii 2015 National Electrical Manufacture
23、rs Association CONTENTS Foreword. ii 1 Scope 1 2 Normative References 1 3 Lamp Designations. 1 4 Physical Characteristics. 1 4.1 Base specifications. 1 4.2 Bulb designations. 2 4.3 Lamp characteristics 2 4.4 Dimensions. 2 4.5 Life. 2 5 Restrictions. 2 5.1 Operating position. 2 5.2 Seal temperature.
24、2 5.3 Bulb wall temperature. 3 5.4 Shielding. 3 6 Test Procedures 3 6.1 Life 3 6.2 Seal (pinch) temperature. 3 6.3 Operating temperature. 3 7 Information for luminaire design. 3 Figure 1 Dimensions of GZ9.5 based T-H projection lamps. 4 Table 1 GZ9.5 based, single-ended T-H lamps with T6 (T19) bulbs
25、, 36.5 mm LCL, 76.2 mm MOL, and proximity reflector. 5 Table 2 Maximum seal temperature. 5 Annex A (Informative). 6 C78.1460-2004 (R2015) Page iv 2015 National Electrical Manufacturers Association C78.1460-2004 (R2015) Page 1 2015 National Electrical Manufacturers Association 1 Scope This standard d
26、efines the dimensional, physical, and other characteristics to assist in the proper application of tungsten-halogen lamps with GZ9.5 bases, T6 (T19) bulbs at 36.5 mm LCL and 76.2 mm maximum overall length with internal proximity reflectors. Lamps of various wattage and voltage designs are included.
27、The grouping of lamps in this standard is based on general physical characteristics. It does not imply that the lamps listed are interchangeable with each other in a particular application. Lamps included in this standard are intended for photographic projection applications.12 Normative References
28、The following standards contain provisions which, through reference in this text, constitute provisions of this American National Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this American National
29、Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. ANSI C78.370-1997, Method for the Designation of Photo Lamps ANSI C78.1450-1983, Method for Life Testing Incandescent Projection Lamps ANSI C79.1-2002, Nomenclature for Glass
30、 Bulbs Intended for Use with Electric Lamps ANSI C81.61-2003, Electric Lamp Bases ANSI/IEC C78.682-1997, Standard Method for Measuring the Seal (pinch)Temperature of Quartz Tungsten-Halogen Lamps 3 Lamp designations The systems for assigning lamp designations, as defined in ANSI C78.370 is commonly
31、employed for the lamps described in this standard. 4 Physical characteristics 4.1 Base specifications Finished lamps employing the GZ9.5 base shall comply with the requirements given in ANSI C81.61. 4.2 Bulb designations 1Informative: In general, the lamps in this standard are compatible with those
32、in IEC Publication 60357. C78.1460-2004 (R2015) Page 2 2015 National Electrical Manufacturers Association Bulb designations are defined in ANSI C79.1. Due to the long-term use of the conventional method of designation, its use will continue herein. Equivalent metric designations are shown in parenth
33、esis, in contrast to the use of metric primary dimensions elsewhere in this standard. 4.3 Lamp characteristics Nominal electrical, physical, and other characteristics of standard lamps are listed in Table 1. 4.4 Dimensions 4.4.1 The lamp drawing of Figure 1 defines the various dimensions and provide
34、s specific values where appropriate. A typical product drawing is shown. Due to eccentricity and offset between the base and the bulb, the bulb may take up more room relative to the fixed position base. Dimension E is the radius of cylindrical space that defines the limit of bulb excursion relative
35、to the centerline between the base pins. The dimension LCL identifies the light center length and is a reference value. Dimension MOL is the maximum overall length. 4.4.2 The light source dimensions width (W), height (H), and thickness (T), define a volume centered on the light center length (LCL) a
36、nd the base centerline within which all luminous parts of the filament shall be located. This is a maximum volume accounting for all possible positions of the filament. Actual filament size may be significantly smaller than the defined light source volume. 4.5 Life The acceptability of life test res
37、ults shall be ascertained in accordance with ANSI C78.1450. 5 Restrictions 5.1 Operating position The lamps specified in this standard are restricted in operating position to that of base down through base horizontal position, unless noted otherwise in Table 1. 5.2 Seal temperature The lamps covered
38、 by this standard are limited in regards to the endurance of the metal-to-envelope seal. These lamps fall into two limiting classes; 400C maximum and 450C maximum. Table 2 shows the limitations of particular lamps. 5.3 Bulb wall temperature C78.1460-2004 (R2015) Page 3 2015 National Electrical Manuf
39、acturers Association The lamps bulb wall temperature shall be maintained above 250C for proper operation of the halogen cycle. An upper limit of approximately 900C is recommended for maintaining the integrity of fused silica bulbs. 5.4 Shielding A protective shield shall be provided relevant to the
40、following cautionary notice: - Tungsten-halogen lamps operate at high temperature and at internal gas pressures above atmospheric pressure. Consequently, a lamp could shatter. Certain lamps may also emit some amount of ultraviolet radiation. Therefore, a suitable protective shield, screening techniq
41、ue, or both, shall be used with the luminaire to protect people and surroundings from both hazards. - The information contained in the lamp manufacturers caution notice shall always be read and observed. 6 Test procedures 6.1 Life Lamps shall be tested in open racks, at the base-down operating posit
42、ion with cooling to maintain temperature limits. Additional procedures are defined in ANSI C78.1450. 6.2 Seal (pinch) temperature The measurement procedure is defined in ANSI/IEC C78.682. 6.3 Operating temperature Standard methods of measuring other lamp operating temperatures (bulb and base) are un
43、der consideration. 7 Information for luminaire design The proper luminaire design must take into account the several aspects of lamp restrictions mentioned in clause 4, operating position, seal temperature, bulb wall temperature, and shielding. C78.1460-2004 (R2015) Page 4 2015 National Electrical M
44、anufacturers Association Standard Dimensions (Millimeters) Lamp designation A nom E max LCL ref MOL W max H max T max FSX FSY EPD EHA EGZ EMG 19.0 19.0 19.0 19.0 19.0 19.0 12.70 12.70 12.70 12.70 12.70 12.70 36.50 36.50 36.50 36.50 36.50 36.50 76.20 76.20 76.20 76.20 76.20 76.20 10.70 10.70 10.67 10
45、.67 11.68 10.67 12.20 12.20 12.85 10.67 11.68 12.19 5.72 5.72 5.72 5.72 5.72 5.72 Figure 1 Dimensions of GZ9.5 based T-H projection lamps C78.1460-2004 (R2015) Page 5 2015 National Electrical Manufacturers Association Table 1 GZ9.5 based, single-ended T-H lamps with T6 (T19) bulbs, 36.5 mm LCL, 76.2
46、 mm MOL, and proximity reflector Lamp designation Rated wattage (watts) Rated voltage (volts) Rated life (hours) Correlated color temp. (K) Operating position FSX FSY EPD EHA EGZ EMG 400 400 485 500 500 500 220 240 240 120 120 220 75 75 50 50 100 75 3200 3200 3250 3250 3200 3100 BDTH BDTH BDTH BDTH
47、BDTH BDTH Table 2 Maximum seal temperature Lamp designation Maximum seal temperature C FSX FSY EPD EHA EGZ EMG 400 400 450 450 450 450 C78.1460-2004 (R2015) Page 6 2015 National Electrical Manufacturers Association Annex A (Informative) IEC 60357-2002, Tungsten Halogen Lamps ANSI/IEC C78.60432-3, 2004, Safety Specifications for Incandescent Lamps Part 2: Tungsten Halogen Lamps NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION 1300 NORTH 17TH STREET, SUITE 900 ROSSLYN. VA 22209www.NEMA.orgTO ORDER ADDITIONAL NEMA STANDARDS VISITWWW.GLOBAL.IHS.COM OR CALL 1-800-854-7179/1-303-397-79565612_0514TB