1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C78.1505-2001Electric lamps: Tungsten-Halogen Lamps with G38 Bases and 127 mm LCLANSI C78.1505-2001 Revision of ANSI C78.1505-I 993 r American National Standard Approved June 18,2001 Secretariat: American National Standards
2、Lighting Group - NEMA Tungsten-Halogen Lamps with G38 Bases and 127 mm LCL INSTRUCTIONS: This revision is intended to replace ANSI C78.1505-1993. Discard this instruction sheet when finished. Copyright O 2001 by American National Standards Lighting Group in Affiliation with National Electrical Manuf
3、acturers Association, 1300 North 17th Street, Suite 1847. Rosslyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 Am e rica n National Standard Approval of an American National Standard requires verification by 0 ANSI that the requirements for due process, consensus, and other criteria f
4、or approval have been met by the standards developer. An American National Standard implies a consensus of those substantially concerned with its scope and provisions. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by dire
5、ctly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The use of American National Standards is
6、completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not deve
7、lop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the righ or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations
8、 should be addressed to the Committee Secretariat whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to r
9、eaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by Information Handling ServiceslGlobal Engineering Documents 15 Inverness Way East, Engle
10、wood, CO 801 12-5776 Under Contract with National Electrical Manufacturers Association hln n-vt nC +hi- nn nhlin-+inn m-ii hn renrrrrlt #,-er4 in cnr IYV pail VI uiia puuiibariuii iiiay UG icpuuuu u III aiiy form, in an electronic retrieval system or otherwise, without prior written permission of th
11、e publisher. Printed in the United States of America Copyright O 2001 by American National Standards Lighting Group in Affiliation with National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-I 993 CONTENTS For
12、eword . i 1 .o 2.0 3.0 4.0 5.0 6.0 7 .O Scope 1 Normative References . 1 Lamp Designations 2 Physical Characteristics . 2 Restrictions 3 Test Procedures 4 Information for Luminaire Design . 5 Annex A : Tables (Normative) 9 Annex 8: Drawings (Normative) . 13 Annex C: Informative References . 17 I Cop
13、yright O 2001 by American National Standards Lighting Group in Affiliation with National Electrical Manufacturers Association. 1300 North 17th Street. Suite 1847. Rosslyn. VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 Foreword (This Foreword is not part of ANSI C78.1505-2001.) Suggestio
14、ns for improvement of this standard should be submitted to the Secretariat C78, National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209. This standard was processed and approved by Accredited Standards Committee on Electric Lamps, C78, and its Sub-Committ
15、ee, C78-1 for Incandescent Lamps. Committee approval of the standard does not necessarily imply that all committee members voted for that approval. At the time this standard was published, the C78 Committee had the following members: AI Rousseau, Chair, C78 all compromises with the actual space are
16、in excess of the actual space required. (2) All excursions of a lamp bulb are shown relative to a fixed-position base. (3) Bulb ?eccentricity? with respect to the base axis is a combination of allowances for angular tilt and lateral displacement. (4) The base shown in the drawing represents a typica
17、l form. The essential dimensions are controlled by the ?Go? gauge for G38 based lamps described in ANSI C81.63. (5) All dimensions are in millimeters unless otherwise specified. 4.4.2 The light source dimensions, diameter (D) and height (H) in Table 1 and width (W), height (H), and thickness (T) in
18、Table 2, define a maximum size volume centered on the Light Center Length and base axis within which all luminous parts of the filament are located. This volume accounts for all positions of the filament. Actual filament size may be significantly smaller than the defined light source volume. 5 Restr
19、ictions 5.1 Operating Positions Lamp types in this standard may operate properly in any position or they may be restricted as to position. Such restrictions are indicated in the Operating Position column of Tables 1 and 2. Copyright O 2001 by American National Standards Lighting Group in Affiliation
20、 with National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847. Rosslyn. VA 22209 3 ANSI C78.1505-2001 Revision of ANSI C78.1505-I 993 5.2 Seal Temperature In the lamps covered by this standard, the metal-to-envelope seal is intended for operation at temperatures not to exce
21、ed 35OOC for lamps with rated life of 500 hours and 4OOOC for lamps with a rated life of 500 hours or less. 5.3 Bulb Wall Temperature A lamps bulb wall temperature shall be maintained about 25OOC for proper operation of the halogen cycle. An upper limit of approximately 900C is recommended for maint
22、aining the integrity of fused silica bulbs. 5.4 Shielding A protective shield shall be provided relevant to the following cautionary notice. To assure maximum safety during handling and use of the subject lamps, observe the following notices: (1) Tungsten-halogen-lamps operate at high temperature an
23、d at internal gas pressures above atmospheric pressure. Consequently, a lamp could shatter. Certain lamps may also emit some amount of ultraviolet radiation. Therefore a suitable protective shield, screening technique, or both shall be used with the luminaire to protect people and surroundings from
24、both hazards. (2) Always read and observe the information contained in the lamp manufacturers caution notice. 6 Test Procedures B 6.1 Life Lamps shall be tested in open racks or fixtures in their specified operating position with cooling to maintain the bulb and seal temperature limits. Suggested te
25、st cycles and additional testing procedures are defined in ANSI C78.1450. It should be noted that life test results from an open rack test procedure may not be representative of lamp life in luminaires or projection equipment. Consult the lamp manufacturer for specific test criteria. 62 Sea! (Pinch)
26、 Temperature The measurement procedure is defined in ANSMEC C78.682. 6.3 Operating Temperature 4 Copyright O 2001 by American National Standards Lighting Group in Affiliation with National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 ANSI C78.1505-2001
27、Revision of ANSI C78.1505-1993 0 Standard methods of measuring other lamp operating temperatures (bulb and base) are under consideration. 7 Information for Luminaire Design Proper luminaire design must take into account the several aspects of lamp restrictions mentioned in Section 5, operating posit
28、ion, seal temperature, bulb wall temperature, and shielding. copyright O 2001 by American National Standards Lighting Group in Affiliation with National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 5 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 THI
29、S PAGE INTENTIONALLY LEFT BLANK 6 Copyright O 2001 by American National Standards Lighting Group in Atfiliation with National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 ANNEXES Copyright O 2001 by Amer
30、ican National Standards Lighting Group in Affiliation with National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 7 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 THIS PAGE INTENTIONALLY LEFT BLANK 8 Copyright O 2001 by American National Standards Lig
31、hting Group in Affiliation with National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn. VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-I 993 ANNEX A - TABLES ( Normative) 9 Copyright O 2001 by American National Standards Lighting Group in Affiliation with N
32、ational Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 THIS PAGE INTENTIONALLY LEFT BLANK 10 Copyright O 2001 by American National Standards Lighting Group in Affiliation with National Electrical Manufactu
33、rers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-I 993 Rated Light ANSI Rated Rated Nominal Avg. Correlated Source” Filament Design. Wattage Voltage Bulb Life Color dimensions Config. Size (Hr.) Temp. (K) (mm) (+I OOK) DH (W) (V) BW
34、A 2000 120 T25(T8) 500 3200 45.0 I 13.0 CC-8 TABLE 1 - Lamp Characteristics Operating Position BD3 TABLE 2 - Lamp Characteristics T40 (T12) or BT40 (BT12) and Smaller Bulbs G38 Mogul Bipost,Base 127 mm Nominal Light Center Length ANSI Design. cw4 cxz CYX FKK Rated Wattage (W) 1 O00 1500 2000 2000 Ra
35、ted Voltage (VI 120 120 120 220,230, 240 216 mm MOL with 1 Size Life T;i (19.5) 13 or C13D Filaments Correlated Color Temp. (K) (+loOK) 3200 3200 3200 3200 Light Source” Dimensions (mm) W 21 18.5 23 23 27 22 27.5 22 - H 20 18.5 24 20.5 29 28 28 25 T 15 15 15 15 15 15 15 15 - Filament Config. C13 CI
36、3D C13 C13D C13 C13D CI 3 C13D Operating Position BDTH” BDTH3 BDTH3 BDTH3 BDTH3 BDTH3 BDTH3 BDTH3 Notes: 1) Lamp manufacturers published values of rated life may vary. 2) See definition of light source in Section 4.4.2. 3) Base down to horizontal. 4) MOL 210mm. 11 Copyright O 2001 by American Nation
37、al Standards Lighting Group in Affiliation with National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 THIS PAGE INTENTIONALLY LEFT BLANK 12 Copyright O 2001 by American National Standards Lighting Group
38、in Affiliation with National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 ANNEX B - DRAWINGS (Normative) Copyright O 2001 by American National Standards Lighting Group in Affiliation with National Electr
39、ical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 13 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 THIS PAGE INTENTIONALLY LEFT BLANK 14 Copyright O 2001 by American National Standards Lighting Group in Affiliation with National Electrical Manufacturers Associ
40、ation, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 Figure 1 Space Limits for Tungsten-Halogen Stage/Studio Lamps T-40 (T12) or BT40 (BT12) and Smaller Bulbs, G38 Base, 127 mm Nominal Light Center Length (LCL) 210 mm Maximum Overall Length (
41、MOL) 216 MOL I Figure 2 Space Limits for Tungsten-Halogen Stage/Studio Lamps T-40 (T12) or BT40 (BT12) and Smaller Bulbs, G38 Base, 127 mm Nominal Light Center Length (LCL) 216 mm Maximum Overall Length (MOL) 15 Copyright O 2001 by American National Standards Lighting Group in Affiliation with Natio
42、nal Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosciyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 THIS PAGE INTENTIONALLY LEFT BLANK 16 Copyright O 2001 by American National Standards Lighting Group in Affiliation with National Electrical Manufacturers
43、 Association, 1300 North 17th Street, Suite 1847, Rocslyn, VA 22209 ANSI C78.1505-2001 Revision of ANSI C78.1505-1993 ANNEX C Informative References ANSI C78.1500-2000, American National Standard for Electric Lamps, Tungsten- Halogen Lamps with P28 Medium Prefocus Bases and 89 mm (3-1/2 in.) LCL. AN
44、SI C78.1501-2000, American National Standard for Electric Lamps, Tungsten- Halogen Lamps with G22 Medium Bipost Bases and 63.5 mm (2-1/2 in.) LCL. ANSI C78.1503-2000, American National Standard for Electric Lamps, Tungsten- Halogen Lamps with G9.5 Medium Two-pin Bases and 60.5 mm (2-3/8 in.) LCL. AN
45、SI C78.1504-2000, American National Standard for Electric Lamps, Tungsten- Halogen Lamps with P28 Medium Prefocus Bases and 55.5 mm (2-3/16 in.) LCL. IEC 60357-1 982, Tungsten Halogen Lamps (non vehicle). Copyright O 2001 by American National Standards Lighting Group in Atfiliation with National Ele
46、ctrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn, VA 22209 17 NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION 1300 NORTH 17TH STREET, SUITE 900 ROSSLYN. VA 22209www.NEMA.orgTO ORDER ADDITIONAL NEMA STANDARDS VISITWWW.GLOBAL.IHS.COM OR CALL 1-800-854-7179/1-303-397-79565612_0514TB