1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C78.62035-2016Electric Lamps Discharge Lamps (Excluding Fluorescent Lamps) Safety SpecificationsANSI C78.62035-2016 Page 1 2016 National Electrical Manufacturers Association ANSI C78.62035-2016 American National Standard for
2、 Electric Lamps Discharge Lamps (Excluding Fluorescent Lamps) Safety Specifications Secretariat: National Electrical Manufacturers Association Approved: July 7, 2016 American National Standards Institute, Inc. ANSI C78.62035-2016 Page 2 2016 National Electrical Manufacturers Association NOTICE AND D
3、ISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in t
4、he development of this document. ANSI standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in
5、the topic covered by this publication. While NEMA administers the process to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments cont
6、ained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance
7、 on this document. NEMA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA doe
8、s not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity
9、, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circum
10、stances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with
11、 the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health- or safety-related information in this document shall not be attributable to NEMA and is solel
12、y the responsibility of the certifier or maker of the statement. ANSI C78.62035-2016 Page i 2016 National Electrical Manufacturers Association AMERICAN NATIONAL STANDARD Approval of an American National Standard requires verification by The American National Standards Institute, Inc. (ANSI) that the
13、 requirements for due process, consensus, and other criteria for approval have been met by the standards developer. An American National Standard implies a consensus of those substantially concerned with its scope and provisions. Consensus is established when, in the judgment of the ANSI Board of St
14、andards Review, substantial agreement has been reached by directly, and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made towa
15、rd their resolution. The existence of an American National Standard does not in any respect preclude anyone, whether s/he has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. It is intended as a guid
16、e to aid the manufacturer, the consumer, and the general public. The American National Standards Institute, Inc., does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interp
17、retation of an American National Standard in the name of the American National Standards Institute, Inc. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on this title page. CAUTION NOTICE: This American National Standard may be revised or withdrawn a
18、t any time. The procedures of the American National Standards Institute, Inc., require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American Natio
19、nal Standards Institute, Inc. Published by National Electrical Manufacturers Association 1300 North 17thStreet, Suite 900 Rosslyn, Virginia 22209 2016 National Electrical Manufacturers Association All rights, including translation into other languages, reserved under the Universal Copyright Conventi
20、on, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American copyright conventions. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written permission of the publisher. Prin
21、ted in the United States of America ANSI C78.62035-2016 Page ii 2016 National Electrical Manufacturers Association Foreword (This foreword is not part of ANSI C78.62035) Suggestions for improvement of this standard should be submitted to the Secretariat C78, NEMA, 1300 North 17thStreet, Suite 900, R
22、osslyn, VA 22209. This standard was processed and approved by Accredited Standards Committee on Electric Lamps, C78. Committee approval of the standard does not necessarily imply that all committee members voted for that approval.ANSI C78.62035-2016 Page 1 2016 National Electrical Manufacturers Asso
23、ciation Chapter I United States of Americas Deviations to IEC 62035 (2014-04) Ed. 2.0 Introduction This standard sets forth safety specifications for discharge lamps (excluding fluorescent lamps) with deviations to IEC 62035 (2014-04) Ed. 2.0. 1 Additions to Normative References Add the following to
24、 Clause 2, Normative References: ANSI C81.61 American National Standard for Electrical Lamp BasesSpecifications for Bases (Caps) for Electric Lamps ANSI C81.62 American National Standard for Electric Lampholders ANSI C81.63 American National Standard for Gauges for Electric Lamp Bases and Lampholder
25、s ANSI C81.64 American National StandardGuidelines and General Information for Electrical Lamp Bases, Lampholders and Gauges ANSI C78.40 American National Standard for Electric LampsSpecifications for Mercury Lamps ANSI C78.41 American National Standard for Electric LampsGuidelines for Low-Pressure
26、Sodium Lamps ANSI C78.42 American National Standard for Electric LampsHigh-Pressure Sodium Lamps ANSI C78.43 American National Standard for Electric LampsSingle-Ended Metal Halide Lamps ANSI C78.44 American National Standard for Electric LampsDouble-Ended Metal Halide Lamps ANSI C78.389 American Nat
27、ional Standard for Electric LampsHigh-Intensity DischargeMethods of Measuring Characteristics ANSI C82.4 American National Standard for Lamp BallastsBallasts for High-Intensity Discharge and Low-Pressure Sodium Lamps UL 1029 Standard for High-Intensity-Discharge Lamp Ballasts UL 1598 Luminaires Alte
28、rnate standards can be substituted for the corresponding IEC standard as listed here: IEC 60061-1 ANSI C81.61 IEC 60061-2. ANSI C81.62 IEC 60061-3. ANSI C81.63 IEC 60188 . ANSI C78.40 IEC 60192 . ANSI C78.41 IEC 60598-1 . UL 1598 IEC 60662 . ANSI C78.42 IEC 60922 . UL 1029 IEC 60923 . ANSI C82.4 IEC
29、 61167 . ANSI C78.43, ANSI C78.44 ANSI C78.62035-2016 Page 2 2016 National Electrical Manufacturers Association 2 Deviations to Clause 5.1 Clause 5.1 does not apply. 3 Deviations to Table 2 Lamps shall be designed to contain all particles within the outer bulb in case an arc tube rupture occurs in a
30、ccordance with either ANSI C78.389, or use Annex I or Annex J as appropriate. 4 Deviations to Annex B In Annex B, Table B.2, the heating temperature for E26 and E39 bases shall be identical to, or greater than, the maximum base temperature given in the ANSI lamp designation code for each lamp type.
31、5 Deviations to Annex E Annex E, Measurement of pulse height for lamps with internal starting device does not apply. 6 Deviations to Annex F Part “a” of clause F.6 does not apply. Add the following note to clause F.6: Note: Lamps operated on lead circuits with a capacitor in series with the lamp or
32、on electronic ballasts will operate such that maximum lamp currents associated with rectification are restricted to values that will not be excessive for the system ANSI C78.62035-2016 Page 3 2016 National Electrical Manufacturers Association Chapter II IEC 62035 (2014-04) Ed. 2.0 The referenced IEC
33、 standard is not included in this document and must be obtained separately. IEC standards are available through the US National Committee of ANSI or IEC. This information is offered for your convenience. American National Standards Institute Attn: “eStandard Store” 25 West 42nd Street, 4th Floor New
34、 York, NY 10036 Call 212-642-4900 during normal business hours. It may also be purchased electronically at www.ansi.org or http:/webstore.ansi.org/ansidocstore/default.asp. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION 1300 NORTH 17TH STREET, SUITE 900 ROSSLYN. VA 22209www.NEMA.orgTO ORDER ADDITIONAL NEMA STANDARDS VISITWWW.GLOBAL.IHS.COM OR CALL 1-800-854-7179/1-303-397-79565612_0514TB