1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1610 Central-Station Burglar-Alarm Units STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL
2、NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Central-Station Burglar-Alarm Units, UL 1610 Fourth Edition, Dated July 5, 2016 Summary of Topics This new edition was issued to incorporate the following changes: 1. Single-path communicati
3、ons, alarm control unit 2. Remote access to alarm panels, via smart devices and/or the internet 3. Expansion of electronic media to include website The new/revised requirements are substantially in accordance with Proposal(s) on this subject dated June 5, 2015, July 17, 2015, August 14, 2015, Octobe
4、r 23, 2015 and January 15, 2016. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is wit
5、hout warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss
6、 of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of
7、 the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while
8、 purchaser is storing an electronic Standard on the purchasers computer system. JULY 5, 2016 UL 1610 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 5, 2016 UL 1610 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR F
9、URTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 5, 2016 1 UL 1610 Standard for Central-Station Burglar-Alarm Units First Edition January, 1985 Second Edition May, 1994 Third Edition October, 1998 Fourth Edition July 5, 2016 This ANSI/UL Standard for Safety consists of the Fourth
10、Edition. The most recent designation of ANSI/UL 1610 as an American National Standard (ANSI) occurred on July 5, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to U
11、L at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and a
12、ll copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 1610-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 5, 2016 C
13、ENTRAL-STATION BURGLAR-ALARM UNITS - UL 1610 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .8 2 General 9 2.1 Components .9 2.2 Units of measurement .9 2.3 Undated references .9 2.4 Termi
14、nology .9 3 Glossary 10 4 Installation and Operating Instructions 13 5 Installation and Operating Instructions Physical Media 14 6 Electric Shock .15 CONSTRUCTION ASSEMBLY 7 General .15 7.1 Product assembly .15 7.2 Electrical protection 15 8 Protection of Service Personnel .21 9 Enclosures 21 9.1 Ge
15、neral 21 9.2 Doors and covers .23 9.3 Enclosure openings 23 9.4 Screens and expanded metal .25 9.5 Cast metal 25 9.6 Sheet metal 26 9.7 Product enclosure mounting 29 9.8 Polymeric materials 29 10 Corrosion Protection 30 FIELD WIRING CONNECTIONS 11 General 30 12 Cord-Connected Products .30 13 Permane
16、ntly-Connected Products .31 13.1 General .31 13.2 Field-wiring terminals .32 13.3 Field wiring leads .35 13.4 Polarity identication 35 14 Grounding .36 INTERNAL WIRING 15 General 37 16 Wiring Methods .38 17 Separation of Circuits .39 18 Bonding for Grounding 39 JULY 5, 2016 CENTRAL-STATION BURGLAR-A
17、LARM UNITS - UL 1610 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL COMPONENTS, ELECTRICAL 19 General 43 19.1 Mounting of components 43 19.2 Insulating materials .44 19.3 Fuseholder 45 19.4 Current-carrying parts .45 20 Overcurrent Protect
18、ion 45 21 Semiconductors 45 22 Switches .45 23 Transformers and Coils 46 SPACINGS 24 General 46 25 Components .49 PERFORMANCE ALL UNITS 26 General 49 26.1 Test units and data .49 26.2 Test samples and miscellaneous data 50 26.3 Test voltages 50 26.4 FCC requirements 50 27 Normal Operation Test 50 28
19、 Incorrect Connection Tests .51 29 Input Test 51 30 Output Measurement Test .51 31 Electrical Supervision Test .52 32 Undervoltage Operation Test .53 33 Overvoltage Operation Test 53 34 Variable Ambient Test .53 35 Humidity Test 54 36 Leakage Current Tests for Cord-Connected Products .54 37 Electric
20、 Shock Current Test 58 38 Overload Test 62 38.1 General .62 38.2 Separately energized circuits 62 39 Endurance Test 63 39.1 General .63 39.2 Separately energized circuits 63 40 Jarring Test 63 41 Dielectric Voltage-Withstand Test .64 42 Temperature Test .65 43 Abnormal Operation Test 69 44 Electrica
21、l Transient Tests 69 44.1 General .69 44.2 Supply line transients .69 44.3 Internally induced transients .71 44.4 Input/output circuit transients 71 45 AC Induction Test .72 46 Polymeric Materials Test .73 47 Battery Replacement Test .73 JULY 5, 2016 CENTRAL-STATION BURGLAR-ALARM UNITS - UL 1610 4UL
22、 COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 48 Drop Test 74 49 Strain Relief Test .74 49.1 Supply cord .74 49.2 Field-wiring leads .75 50 Ignition Through Bottom-Panel Opening Tests 75 50.1 General .75 50.2 Hot, aming oil .75 50.3 Molten P
23、VC and copper .76 51 Mechanical Strength Tests for Enclosures .76 52 Special Terminal Assemblies Tests .77 52.1 General .77 52.2 Disconnection and reconnection .77 52.3 Flexing test 78 52.4 Millivolt drop test .78 52.5 Temperature test .78 INTRUSION DETECTION DEVICES 53 General 78 CONTROL UNITS 54 G
24、eneral 79 DIRECT-WIRE SYSTEMS 55 General 79 56 Alarm Receiving Units .80 57 Subscriber Units 80 TRANSMITTER SYSTEMS 58 General 80 59 Dual Signal Line Transmission Methods .81 60 Single Signal Line Transmission Methods 83 61 Central-Station Units 84 62 Subscriber Control Units .85 COMBINATION SYSTEMS
25、 63 General 85 MULTIPLEX SYSTEMS 64 General 86 65 Operation 86 66 Packet Switched Data Networks 89 67 Central-Station Units 91 68 Subscriber Control Units .91 69 Remotely Accessible Control Units 91 69.1 General .91 69.2 Validation of remote access credential 92 69.3 Communication 93 JULY 5, 2016 CE
26、NTRAL-STATION BURGLAR-ALARM UNITS - UL 1610 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 69.4 Communications data integrity standards 94 69.5 Software/Firmware upgrade .95 69.6 Data integrity standards .96 69.7 Software/Firmware deployme
27、nt process .96 69.8 Event log 97 70 Automated System Units 97 71 Satellite Stations 98 72 Private Radio Facilities 98 ACKNOWLEDGMENT SIGNAL 73 General 99 74 Attack Tests 99 75 Compromise Test 100 76 Encrypted Line Security Equipment .102 POWER SUPPLIES GENERAL 77 Common Requirements 102 RECHARGEABLE
28、 (SECONDARY) BATTERIES 78 General 103 NONRECHARGEABLE (PRIMARY) BATTERIES 79 General 104 PERFORMANCE 80 Power Failure .105 SHORT RANGE RADIO FREQUENCY (RF) DEVICES 81 General 106 82 Time to Report Alarm 107 83 Inoperative Transmitter Reporting 107 84 Battery Status Indication 108 85 Tamper Protectio
29、n .108 86 Interference Protection .109 87 Reference Level Determination 109 87.1 Method 1 .109 87.2 Method 2 .111 88 Interference Immunity 114 89 Frequency Selectivity 115 90 Clash 116 91 Clash Error .117 92 Error (Falsing) Rate 117 93 Throughput Rate 119 94 Transmitter Stability Test .120 95 Transm
30、itter Accelerated Aging Test 120 JULY 5, 2016 CENTRAL-STATION BURGLAR-ALARM UNITS - UL 1610 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 96 Installation Instructions and User Manual .120 MANUFACTURING AND PRODUCTION-LINE TESTS FOR HIGH-V
31、OLTAGE PRODUCTS 97 General 121 98 Production-Line Dielectric Voltage-Withstand Test .121 99 Production-Line Grounding Continuity Test .122 MARKING 100 General .122 101 Marking Permanency Tests 125 ACCESSORY EQUIPMENT 102 General .125 103 Construction .126 104 Performance (Installation) Test .126 105
32、 Marking .126 APPENDIX A Standards for ComponentsA1 APPENDIX B B1 User Validation (Remote Devices) B1 JULY 5, 2016 CENTRAL-STATION BURGLAR-ALARM UNITS - UL 1610 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These
33、requirements cover components of central-station burglar-alarm systems intended and specically designated for burglary-protection use at mercantile and banking premises, on mercantile safes, and on bank safes and vaults. 1.2 The components covered by these requirements are intended for use in a burg
34、lar-alarm system in which the operations of electrical protection circuits and devices are transmitted automatically to, recorded in, maintained from, and supervised from a central-station that employs trained operators and alarm investigators who are in attendance at all times. 1.3 These requiremen
35、ts serve as the basis of classication of central-station burglar-alarm system transmission methods. The systems may be classied as either standard line security equipment or encrypted line security equipment by virtue of the construction and performance requirements for components of that system. Ho
36、wever, requirements covering the complete systems are contained in the Standard for Central-Station Alarm Services, UL 827. 1.4 Protective devices installed on individual properties are further classied as to extent of protection at each location, according to the requirements covering installation
37、and classication (of extent) of alarm protective equipment at individual locations as published in the Standard for Installation and Classication of Burglar and Holdup Alarm Systems, UL 681. 1.5 If equipment covered by these requirements is intended for use in a combination burglar-alarm and re-prot
38、ective signaling system, the portion of the equipment serving a re-alarm function is covered by the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864. 1.6 Systems covered by these requirements operate using Class 2 remote-control and signaling circuits as dened by Article 725
39、 of the National Electrical Code, NFPA 70. 1.7 The requirements assume that standard telephone operating practices are acceptable for leased or other lines connecting to a central-station as dened by Article 800 of the National Electrical Code, NFPA 70. JULY 5, 2016 CENTRAL-STATION BURGLAR-ALARM UNI
40、TS - UL 1610 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 General 2.1 Components 2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix
41、A for a list of standards covering components used in the products covered by this standard. 2.1.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, o
42、r b) Is superseded by a requirement in this standard. 2.1.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.1.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended
43、for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 2.2 Units of measurement 2.2.1 If a value for measurement is followed by an equivalent value in other units in parentheses, the second value may be
44、only approximate. The rst stated value is the requirement. 2.2.2 Unless otherwise indicated, all voltage and current values specied in this standard are rms. 2.3 Undated references 2.3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted a
45、s referring to the latest edition of that code or standard. 2.4 Terminology 2.4.1 The term product as used in this standard refers to all types of central-station burglar-alarm units. JULY 5, 2016 CENTRAL-STATION BURGLAR-ALARM UNITS - UL 1610 9UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRO
46、DUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3 Glossary 3.1 For the purpose of this standard, the following denitions apply. 3.2 ACKNOWLEDGMENT SIGNAL An audible and/or visual signal that is sent to the subscriber by the central station to notify the subscriber that a signal has been received
47、indicating that the protection system has been properly armed. The acknowledgment signal can be sent manually or automatically. 3.3 ADMINISTRATOR An authorized entity that is in possession of the credentials necessary for the ability to perform an upgrade to a control units software and/or rmware. 3
48、.4 BIOMETRICS Authentication of human physical characteristics used to identify an individual. 3.5 CIRCUITS, ELECTRICAL: a) High-Voltage A circuit involving a potential of not more than 600 volts and having circuit characteristics in excess of those of a low-voltage power-limited circuit. b) Low-Vol
49、tage A circuit involving a potential of not more than 30 volts rms, 42.4 volts DC or AC peak. c) Power-Limited A circuit whose output is limited as specied in Tables 3.1 and 3.2. The power limitation shall be provided by the construction of the transformer, a xed impedance, a noninterchangeable fuse, a nonadjustable manual reset circuit protective device, or a regulating network. Table 3.1 Power limitations for inherently limited power source (overcurrent protection not required) Circuit vol