1、A-A-5 O0 40 November 1, 1982 COMMERCIAL ITEM DESCRIPTION FILTER UNIT, COOKING GREASE, PRESSURE The General Services Administration has authorized the use of this commercial item description in preference to type II, size 1 and type III, size 1 of Military Specification MIL-F-2296. Salient characteri
2、stics. Design and construction. The filters shall be designed to filter liquified, solidifying, or nonsolidifying frying medium used in deep fat fryers and doughnut machines at a rate of 3 gallons per minute minimum. electric motor(s), as specified, pump(s), reservoir, hoses, filters, controls and f
3、ittings and have a means for fast draining of the system. the following types and sizes: The filter shall consist of an The filters shall be of Type II - Gravity or pumped drain and pumped refill Size 1 - 50-pound minimum reservoir capacity Style A - 120 V, 60 Hz, single phase Style B - 220 V, 50 Hz
4、, single phase Type III - Pumped suction drain and pumped refill Size 1 - 80 pound minimum reservoir capacity Style A - 120 V, 60 Hz, single phase Style B - 220 V, 50 Hz, single phase Type II, size 1 filters may be equipped with a reversing capability to permit pumped suction, from fryer to filter,
5、or they shall be capable of being rolled under the fryer drains where they can be filled. shall not exceed a height of 13-3/4 inches, exclusive of the handle. Type III, size 1 filters shall have a reversing capability to permit pumped suction as well as pumped refill each at a minimum rate of 3 gall
6、ons per minute. assembly shall be supplied with sufficient filters necessary for 100 filtering operations and each filter be capable of being easily removed and replaced. When a filtering compound is necessary to perform the complete filtering process, a sufficient quantity shall be supplied for at
7、least 100 filtering operations and the compound shall restore color and remove odor and taste from the frying medium. The filters, when used with or without the filtering compound, as recommended by the manufacturer, shall retain particles 10 microns and larger. shall be mounted on swivel casters: t
8、o or greater than the weight of the filter assembly and the rated load of the reservoir. food handling service and be capable of withstanding th& temperatures normally encountered in filtering operations. The filters sanitation standard shall comply with the requirements set forth in the National Sa
9、nitation Foundation Standard No. 4, as applicable. Filters without the reversing capability Each type of filter The filter assemblies the total load rating of which shall be equal All materials in contact with the frying medium shall be acceptable for FSC 7330 THIS DOCUMENT CONTAINS -4 PAGES. Provid
10、ed by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-SOOYO 73 a 747777Y 001750l1 2 A-am so O RwxO, The reservoir shall be fabricated of stainless steel or aluminum of sufficient thickness to prevent dents or damage which would impair function in noml operat
11、ion, the type II, size 1 and 80 pounds for the type III, size 1, The reservoirs shall have a minimum fat capacity of 50 pounds for Electrical requirements. Hp and be equipped with an overload protection device, filters shall be of the reversing type, 120 V, 60 Hz, single phase, motors for style B un
12、its shall be rated for 220 V, 50 Hz, single phase. Filters shall be supplied with a 6 foot (mnimum) power supply cord and have provisions for storing cord when not in use. V, 60 Hz, 1 Ph power shall have a NEMA 5-15P plug assembled to the end of the cord, Controls for motor(s) and pump(s) operation
13、shall be rigidly mounted in a location easily accessible to the operation, capability shall be supplied with a switch clearly indicating wether the filter is in Che pumped suction or the pumped refill mode, Filters shall be supplied with motors of not less than 1/4 Motors for style A units shall be
14、rated for The motors for the type III Filters designed for 120 Filters having the reversing Instruction plate, to it in a readily visible area, The plate shall contain the manufacturers standard operating instructions etched, embossed, or die-stamped. The filters shall have an instruction plate perm
15、anently attached Standard compliance, Sanitation Foundation Standard No, 4 and Underwriters Laboratories Standard No, 197. The cooking grease filters shall comply with the National Identification plate, L Standard No, 197, the identification plate shall include the contract number and national stock
16、 number, In addition to the marking and identification requirements of Certification, salhnt characteristics of this description, and that the product conforms to the The contractor shall certify that the product offered meets the producers l own drawings , specifications , standards and quality ass
17、urance practices and is the same product sold in the commercial marketplace. The Government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract. Regulatory requirements, materials in acco
18、rdance with Public Law 94/580 to the maximum extent practicable. The offeror/contractor is encouraged to use recovered Packaging A, Packagingi, accordance with commercial practice. The cooking grease filters shall be preserved and packaged in B, Uniform Freight Classification or National Motor Freig
19、ht Classification, as applicable Packin&, Packing shall be in accordance with comercial packing complying with 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-SOOLIO 73 W 777777q 0037502 i.I A-A-5 0040 C. Marking. Commercial markings are accept
20、able, provided the following information is included: National Stock Number Item Description Quant it y Date of Pack Contract Numb er Name, Address and Zip Code of Manufacturer Y Source of Information for Non-Government Association Documents P National Electrical Manufacturers Association 2101 L. St
21、reet, N.W. Washing ton, DC 20037 National Sanitation Foundation (NSF) - National Sanitation Foundation P.O. Box 1468 Ann Arbor, MI 48.105 Underwriters Laboratories, Inc. (UL) - Underwriters Laboratories Inc. 33 Pfingsten Road, Northbrook, IL 60062 National Motor Freight Tra-ffic Association, Inc., A
22、gent National Motor Freight Classification American Truckim Associations, Inc., Traffic Department 1616 P. Street, N.W., Washington, DC 20036 Uniform Classification Committee, Agent Uniform Freight Classification Uniform Classification Committee, Suite 1106 222 South Riverside Plaza, Chicago, IL 606
23、06 MILITARY INTERESTS : Custodians L Army - GL Navy - SA Air Force - 99 1 Review Activities Army - MD Navy - MC, MS DLA - GS User Activity Army - CE PREPARING ACTIVITY: Army - GL Project No. 7310-0666 CIVIL AGENCY COORDINATING ACTIVITY: GSA - OPP 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-