1、- MIL-D-51533A 42 = 9999906 0500879 1 *- 4 I MIL-D-51533A(EA) - SUPERSEDING MIL-D-5 15 3 3 (EA) 13 December 1989 MILITARY SPECIFICATION DECONTAMINATING APPARATUS: PORTABLE, 14 LITER, M13 This specifcation is approved for use by the US. Army Chemical Research, Development and Engineering Center, Depa
2、rtment of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of assembled decontaminating apparatus (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 Government documents. O 2.1.1 Specifications, standards, and
3、 handbooks. The following specifications, stan- dards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Depart- ment of Defense Index of Specifications and Standards (DODISS) and
4、supplement thereto, cited in the solicitation (see 6.2). Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, U.S. Army Chemical Research, Development and Engineering Center, ATTN: SMCCR-P
5、ET-S, Aberdeen Proving Ground, MD 2 10 10-5423 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. b AMSC NIA FSC 4230 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided b
6、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. MIL-D-51533A 42 I 9997906 O500880 8 I t- ;Q MIL-D-5 15 33A(EA) SPECIFICATIONS FEDERAL PPP-B-5 85 - Boxes, Wood, Wirebound PPP-B-636 - Boxes, Shipping Fiberboard PPP-F-32 O - Fiberboard: Corrugated and Solid She
7、et Stock (Container Grade) and Cut Shapes. STANDARDS MILITARY MIL-STD-1168 - Ammunition Lot Numbering (Unless otherwise indicated, copies of federal and military specifications, standards, and handbooks are available from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Phi
8、ladelphia, PA 191 11-5094.) 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicita- tion. U.
9、S. ARMY CHEMICAL RESEARCH, DEVELOPMENT AND ENGINEERING CENTER DRAWINGS 5-51-527 - Decontaminating Apparatus: Portable, 14 Liter, M13 5-51-573 - Packaging and Marking 5-51-574 - Palletization and Marking 5-51-582 - Packing and Marking I (Copies are available from Commander, U.S. Army Information Syst
10、ems Command, AT“: ASQNC-ARI-IOT, Rock Island, IL 61299-7210.) 2.2 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulatio
11、ns unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Materials. All materials cited on Drawing 5-51-527 and on the subsidiary drawings shall conform to the specifications and drawings listed thereon. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without lice
12、nse from IHS-,-,-MIL-D-51533A 42 W 99999Gb 05001 T 3.2 Components. All components of the decontaminating apparatus shall conform to the specifications and drawings listed on Drawing 5-51-527 and subsidiary drawings. O 3.3 Manufacture and assembly. The decontaminating apparatus shall be manufactured
13、and assembled in accordance with Drawing 5-51-527. 3.4 Spray characteristics. At room conditions the decontaminating apparatus shall be capable of being primed with no more than 10 strokes of the pump piston. With the wand held horizontally a minimum of 4 feet above the outlet of fluid container, sp
14、ray shall be projected a horizontal distance of at least 3 feet and no leakage shall occur when the pump is activated and tested in accordance with 4.4.6.1. 3.5 First article. Unless otherwise specified in the contract, a sample of decontaminat- ing apparatus shall be subjected to the first article
15、inspection specified in 4.3 prior to the start of regular production and whenever there is a lapse in production for a period in excess of 90 days or whenever a change occurs in manufacturing process, material, drawings, speci- fications, or source of supply as to significantly affect product unifor
16、mity as determined by the Government. 3.6 Workmanship. The decontaminating apparatus shall be free from cracks, dents, sharp edges, unpainted surfaces, rust, and foreign matter such as dirt, grease, and oily or viscous materials. 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unl
17、ess otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements (ex- aminations and tests) as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any other fac
18、ilities suitable for the per- formance of the inspection requirements specified herein, unless disapproved by the Govern- ment. The Government reserves the right to perform any of the inspections set forth in this specification where such inspections are deemed necessary to ensure supplies and servi
19、ces conform to prescribed requirements. 4.1.1 Responsibility for compliance. All items shall meet all requirements of sections 3 and 5. The inspection set forth in this specification shall become a part of the contractors overall inspection system or quality program. The absence of any inspection re
20、quirements in the specification shall not relieve the contractor of the responsibility of ensuring that all products or supplies submitted to the Government for acceptance comply with all require- ments of the contract. Sampling inspection, as part of manufacturing operations, is an ac- ceptable pra
21、ctice to ascertain conformance to requirements, however, this does not authorize submission of known defective material, either indicated or actual, nor does it commit the Government to accept defective material. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license
22、from IHS-,-,-MIL-D-51533A 42 9999906 0500882 I MIL-D-5 15 33A(EA) 4.1.2 Contractor assurance of compliance. The contractors quality program or de- tailed inspection system shall provide assurance of compliance of all characteristics with the applicable drawing, special packaging instruction, and spe
23、cification requirements using, as a minimum, the conformance criteria specified herein. 4.1.3 Alternative inspection provisions. Alternative inspection procedures, methods, or equipment, such as statistical process control, tool control, and other types of sampling procedures may be used by the cont
24、ractor when they provide, as a minimum, the level of quality assurance required by the inspection provisions specified herein. Prior to applying such alternative procedures, methods, or equipment, the contractor shall describe them in a written proposal submitted to the Government for evaluation and
25、 approval. (See 6.3.) When required, the contractor shall demonstrate that the effectiveness of each proposed alternative is equal to or better than the quality assurance provisions specified herein. In cases of dispute as to whether the contractors proposed alternative provides equal quality assura
26、nce, the provisions of this specification shall apply. All approved alternative inspec- tion provisions shall be specifically incorporated into the contractors quality program or detailed inspection system, as applicable. 4.2 Classification of inspections. The inspection requirements specified herei
27、n are clas- sified as follows: (a) First article inspection (see 4.3) (b) Quality conformance inspection (see 4.4) 4.3 First article inspection. 4.3.1 Inspections to be performed. As determined by the Government, the first article sample items shall be examined and tested in accordance with this spe
28、cification using either the first article procedures in 4.3.3 or other first article procedures which will be provided by the Government. As determined by the Government, the sample first article items may be subjected to any or all of the examinations and tests specified in this specification and b
29、e inspected for compliance with any or all of the requirements of the applicable drawings and special packaging instructions. 4.3.2 Sample. The first article sample shall consist of 100 decontaminating apparatus manufactured and packaged using the same methods, materials, equipment, and processes as
30、 will be used during regular production. The first article sample shall be submitted for inspection and approval in accordance with the terms of the contract. . 4.3.3 Inspection procedure (see 6.4). 4.3.3.1 For examination and test. Twenty decontaminating apparatus shall be taken at random from the
31、first article sample and subjected to the spray characteristics test specified in 4.4.6.1. Twenty decontaminating apparatus and the packaging thereof shall be taken at 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-v MIL-D-51533A 42 W 999998b 0500
32、883 3 MIL-D- 5 1 5 3 3A(EA) random from the first article sample and examined for all of the remaining characteristics in the classification of characteristics using the inspection methods specified therein. 4.3.4 Acceptance criteria. If any first article sample item fails to comply with any of the
33、applicable requirements, the first article sample shall be rejected. The Government re- serves the right to terminate inspection upon any failure to comply with any of the require- ments. The contractor shall obtain written approval from the contracting activity prior to proceeding with regular prod
34、uction. 4.4 Quality conformance inspection. 4.4.1 Lotting. A lot of decontaminating apparatus shall consist of those like items pro- duced at the same place utilizing the same batches of materials, lot of components, process runs, fabrication techniques, assembly methods, tools, equipment and facili
35、ties but shall not exceed one months production. Each lot shall be controlled and identified in accordance with MIL-STD-1168. No more than one interfix lot number of filled fluid containers shall be contained in any one lot of decontaminating apparatus. 4.4.2 Sampling. Sampling shall be conducted in
36、 accordance with the classification of characteristics in 4.4.5 and, when specified, table I. Samples shall be selected at random. 4.4.3 Inspection procedure (see 6.4). Every item in the lot shall be inspected for criti- cal characteristics. The lot represented shall be rejected when nonconformance
37、to a critical characteristic is found. Sample items and, when applicable, the packaging thereof shall be examined and tested in accordance with the classification of characteristics in 4.4.5. Failure of any sample item to conform to any characteristic in the classification of characteristics based o
38、n the sampling and acceptance criteria specified therein shall be cause for rejection of the lot represented. 0 4.4.4 Inspection characteristics. Critical characteristics are characteristics whose non- conformance to specified requirements is likely to result in hazardous or unsafe conditions for in
39、dividuals using, maintaining, or depending upon the product or whose nonconformance to specified requirements is likely to prevent performance of the tactical function of a major end item. Major characteristics are characteristics whose nonconformance to specified re- quirements is likely to result
40、in failure or to reduce materially the usability of the item for its intended purpose. Minor characteristics are characteristics whose nonconformance to specified requirements is not likely to reduce materially the operation or usability of the item for its intended purpose. 5 Provided by IHSNot for
41、 ResaleNo reproduction or networking permitted without license from IHS-,-,-7 MIL-D-51533A 42 M 99999b 0500884 5 M Lot size 2 to 8 9 to 15 16 to 25 26 to 50 51 to 90 91 to 150 151 to 280 281 to 500 501 to 1200 1201 to 3200 3201 to 10000 10001 to 35000 35001 to 150000 150001 to 500000 500001 and over
42、 MIL-D-51533A(EA) TABLE I. Samriline I * * * * * * * * * 1250 1250 1250 1250 1250 1250 II * * * * * * * 315 315 315 315 315 490 715 715 Inspection levels and sami m - * * * 9 * 125 125 125 125 125 192 294 294 345 435 IV - * * * * 50 50 50 50 75 116 116 135 170 200 244 V * Y * 32 32 32 32 48 73 73 86
43、 108 123 156 189 VI - * * 20 20 20 20 20 47 47 53 68 77 96 119 143 - VII - * 13 13 13 13 13 20 29 34 42 50 60 74 90 102 - e sizes WI * 8 8 8 8 12 19 21 27 35 38 46 56 64 64 - Ix 5 5 5 5 7 11 13 16 19 23 29 35 40 40 40 - X 3 3 3 5 6 7 10 11 15 18 22 29 29 29 29 - - *Indicates one hundred percent insp
44、ection. If sample size exceeds lot size, perform one hundred percent inspection. Accept the lot represented on zero nonconforming characteristics and reject the lot represented on one or more nonconforming characteristics for all inspection levels. - XI 2 2 3 5 5 6 7 9 11 13 15 15 1.5 15 15 - - 4.4.
45、5 Classification of characteristics. Quality conformance examinations and tests shall be as specified in the following classification of characteristics paragraphs. When specified herein, accept on O and reject on 1 attributes sampling inspection shall be per- formed on the designated characteristic
46、s using the stated levels in table I for selection of sample sizes. 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ARAGRAPH i. 4.5 (a) ITLE Iecontaminating apparatus: portable, 14 liter, M13 CAT EGO RY DRAWING NUM 5-51-527 SHEET OF NEXTHIGHERL Cri
47、tical Major 101 102 103 104 105 Minor 201 202 NIL-D-51533A 42 W 9999906 0500885 7 MIL-D-5 1533A(EA) CLASSIFICATION OF CHARACTERISTICS CHARACTERISTIC None defined Width Height Length Spray characteristics Specified components correctly assembled Labels evident and correctly assembled Workmanship VOTE
48、S: CE - Commercial inspection equipment VI - Visual inspection SAMPLING AND ACCEPTANCE CRITERIA Table I, Level VII Table I, Level VII Table I, Level VII 4; Acc O, Rej 1 able I, Level VII Table I, Level IX Table I, Level W IEQUIREMENl PARAGRAPH 3.2 3.2 3.2 3.4 3.2 and 3.3 3.2 3.6 INSPECTI( METHO1 CE
49、CE CE 4.4.6.1 VI VI VI Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PARAGRAPH I. 4.5 (b) CATEGORY Critical Major 101 102 103 104 105 i 06 107 108 Minor 201 MIL-D-51533A 42 9999906 R50RAb 9 MIL-D-5 1533A(EA) CLASSIFICATION OF CHARACTERISTICS ITLE ackaging - Packing - Palletization DRAWING NUMBER 5-51-573, 5-51-574 5-51-582 OF NEXTHIGHERASSY CHARACTERISTIC None defined Item compl