1、L I MIL-D-63147 Lt W 9999906 0252598 1 p- MIL-D=63147(AR) 31 MAY 1977 MILITARY SPECIFICATION DISPENSER TEST ADAPTER ASSEMBLY This specification is approved for use by the U.S. Amy Armament Research and Development Command, and is available for use by all Departments and Agencies of the Department of
2、 Defense, 1_,1 This specification covers the performance and acceptance inspection requirements for the Dispenser Test Adapter Assembly associated with the Purpose Dispenser. M-IL30 Aircraft General 2. APPLICABLE DOCUMENTS 2.1 The following documents of issue in effect on date of invitation for bids
3、 or request for proposal, form a part of this specification to the extent specified herein. SPECIFICATIONS MILITARY MIL-A-48078 - Ammunition, Standard Quality Assurance Provisions, General Specification For STANDARDS MILITARY MIL-STD-105 - Sampling Procedures and Tables for Inspection by Attributes
4、MIL-STD-109 - Quality Assurance Terms and De finitions MIL-STD-810 - Environmental Test Methods MIL-STD-202 - Test Methods for Electronic and Electrical Component Parts MIL-STD-1460 - Soldering of Electrical Connections and Printed Wiring Assemblies, Pro- cedures For . FSC: 4925 t the end of this do
5、cument i / .- ._ i .? - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-63147 47 = 797970b 0252577 3 MIL-D-63149 (KR) DRAWINGS (See 6.5) U.S. ARMY ARMAMENT RESEARCH AND DEVELOPMENT COMMAND 9311275 - Dispenser Test Adapter Assembly 9322169 - Pac
6、king and Marking for BOX, Exterior for Dispenser Test adapter Assembly (Copies of specifications, standards, drawings and publica- tions required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the Contracting Officer.)
7、. 2,2 Other pubI.iea%iuns. - The following documents form a part of this specification to the extent specified her.ein. Unless otherwise indicated, the issue in effect on the date of invitation or bids or request for proposal shall apply. CODE OF FEDERAL REGULATIONS Title 49 - ,Transportation, Parts
8、 100-199 (The Code of Federal Regulations is available from the Superin- tendent of Documents, U.C, Government Printing Officer, Washington, D.C. 20402. Orders should specify, “49 CFR 100-199 (latest revision) . ) f 3. REQUIREMENTS 3.1 Materials. - Materials shall be in accordance with the applicabl
9、e drawings and specifications. 3.2 Components and assemblii-s. - The components and assemblies shall comply with all requirements specified on drawing 9311275 and associated drawings and with all require- ments specified in- applicable specifications and standards. shall be 0.1 ohms between the poin
10、ts in Table 1 when tested in accordance with 4.5.1. - 3.3 Circuit resistance. - The maximum circuit resistance 2 - - i I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-c. 1 i t - % FROM El E2 E3 E4 E5 E6 E7 E8 E9 El O El 1 E12 El 3 E14 E15 E16 - :I
11、MIL-D-63LLI7 49 W 9979906 0252600 b W MIL-D-63147 (AR) TABLE 1 TO J1 -A J1 -B J-C J1-D J1-E J1-F J1-G J1 -H J1-J J1 -K J1-L J1-M J1-N . J1 -P . J1-R J1-S TO - BROM - E17 El 8 E19 E2 O E21 E2 2 E2 3 E2 4 E25 E26 E2 7 E2 8 E2 9 E30 P5-A J1-T 51 -U J1-v J1-W J1 -X s1-Y J1-2 51-a Jl-b J1-c J1 -d J1-e J1
12、-f J1-g P1 -A Mode Select Switch Chaff MAN Chaff PGRM Flare RIPPLE . Flare MAN FROM P5 -A P5 -A P5-A P5-A P5-A P5-B P5 -B P5-B P5-B P5-B P2-F P3-A P3-M P4-6 P4-6 - TO P2-P P3-P P4-8 J1-t 31-2 91 -B P2-R P3-R P4-9 J1-BB P3-F P4-1 P4-5 P4-2 J1-CC - TO - FROM J1 -y P3-A J1-y P3-B J1-y P3-M - J1 -y P3-s
13、 3.4 Insulation resistahce. - The insulation resistance of each isolated pin to alcother pins (See Table 2) electri- cally connected together shall be 20 megohms minimum when tested in accordance with 4.5.2. (NOTE: Mode Select Switch must be in “CHAFF MAN“ posibtion during this test.) TABLE 2 P3 -.F
14、, B, M, S 3 .I - “ f LJ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-631Li7 47 = 7777706 0252bOL 8 W I 3.5 Environmental requirements. = The dispenserimst adapter assembly shall maintain the circuit resistance and insulation resistance as sp
15、ecified in 3.3 and 3.4 respectively after exposure to the environments specified herein. 3.5.1 Transpoytation vibk-ation. - The dispenser test adapter assembly shall be subjected to the transportation vibration requirements of MIL-STD-810, Method 514.2, Procedure X. three mutually perpendhi!.ar axes
16、. The dispenser test adapter assembly shall be vibrated along 3.5.2 Temperature and humidity. - The dispenser test adapter assembly shall perform all functions satisfactorily after being subjected to Test 105 of MIL-STD-331. Two four- teen day cycles shall be completed for a total test period of 28
17、days. 3.6 Wiring and soldering. - Soldering of electrical wires, cables, connectors, components and assemblies shall be performed in a thorough, workmanlike manner in accordance with MIL-STD-1460. 3-7 First article ihspecthn. - This specification eon- tains technical provisions for first article ins
18、pection. Re- quirements for the submission of first article samples by the contractor shall be as specified in the contract. 3.8 Workmanshi . - All parts and assemblies shall be all manufacturing, processing and assembly operations shall be correctly performed. sharp edges, unblended radii, surface
19、defects, chips, dirt, grease and oil (except where specifically required), corrosion products and other foreign matter. shall not be injurious to any part or assembly nor shall they be contaminated by the cleaning agent. Exterior surface coatings shall be continuous-except for a few light scratches
20、not exposing base material. neat and sharply defined. fabricated _fr_rp and inished in a thorough workmanlike manner, and They shall be clean and free of burrs, The cleaning method used A11 required markings shall be Required packing shall be-dry. 4. QUALITY ASSUiWNCE PROVISIONS 4.1 Responsibility f
21、or inspection and standard qualia assurance brovisiohs. - Unless otherwise specified herein or in the contract, the provisions of MIL-A-48078 shall apply and are hereby made a part of this detail specification. . - .- I i 4 I Provided by IHSNot for ResaleNo reproduction or networking permitted witho
22、ut license from IHS-,-,-MIL-D-63147 Ll7 7777706 0252602 T MIL-D-63147 (AR) 4,2 Classification of inspections. - The following types of inspection shall be conducted on this item. a. First Article Inspection b. Quality Conformance Inspection 4.3 First article inspection 4.3-1 Submission, - The contra
23、ctor shall. submit a first article ample as designated by the Contracting Officer for evaluation in accordance with provisions of 4,3.2 and 4.3.3, The first article sample shall consist of the following items in sample quantities as indicated, Part Description Drawings Quapatity Dispenser Test . .Ad
24、apter Assembly 9311275 2 4.3.2 Inspctlns to“.be pe.r:fo:mdr. - See MIL-A-48078 and paragraphs 4.4.2.1 through 4,422.8, ,testing per paragraph 4.4.38 and Table I specified herein. 4.3.3 -Rejection, - See MIL-A-48078. .5 i i- Provided by IHSNot for ResaleNo reproduction or networking permitted without
25、 license from IHS-,-,-_. MIL-D-63147 47 7779706 0252603 I L I h rn 2 k a U P $ U W a f9 k a *“ -. : I c I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-l i I MIL-D-63L47 49 W 7797906 0252633 O M . MIL-D-63147 (AR) 4.4.3 Testinq 4.4.3.1 Circuit resi
26、stance. - Major Defect - Each dispenser test adapter assembly shall be subjected to this test, The test shall. be performed as specified in 4.5.1 using equipment in accordance with 4.4.4, If any unit fails to comply with the applicable requirements, it shall be classi- fied defective and removed fro
27、m the lot, 4,4,3.2 Insulation resistance. - Major Defect - Each dispenser test adapter assembly shall be subjected to this test, The test shall be performed as specified in 4.5.2 using equipment in accordance with 4.4.4. If any unit fails,to comply wit31 the applicable requirements, it shall be clas
28、sified defective and removed from the lot. 4.4.3.3 Transportation vibration. - Major Defect - Each dispenser test adapter assembly submitted for first article testing shall be subjected to this test. performed as specified in 4.5.3 using equipment in accordance with 4.4.4. If any unit fails to compl
29、y with the applicable requirements, the first article sample shall be rejected. The test shall be 4.4.3.4 Temperature and humidity. - Major Defect - Each dispenser test adapter assembly submitted for first article testing shall be sbjected to this test. performed as specified in 4.5.4 using equipmen
30、t in accordance with 4.4.4. requirements, the first article sample shall be rejected. The test shall be If any unit fails to comply with the applicable 4.4.3.5 Improper soldering.- Major Defeat - Each dis- penser assembly shall be inspected for improper soldering in accordance with 3.5. assembly fai
31、ls to comply 5th the requirements of 3i5, the unit shall be classified defective and removed from the lot. If any-wiring or printed circuit card 4.4.4 Inspection equipment. - Irhe inspection equipment required to perform the inspections and tests prescribed in this specification is identified in the
32、 “Paragraph Reference/ Inspection Method“ column in the tables starting with para- graph 4.4.2.1, and the test method paragraphs (see 4.5) . The contractor shall submit for approval, inspection equipment designs in accordance with the terms of the contract, See SectYon 6 of MIL-A-48078, and Section
33、6.3 herein. 14 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-63147 47 W 777770b 0252632 2 W MEL-D-63147 (AR) 4 o 5 Test methodss arid pmcedWes 4.5.1 Circuit resistahce. - Electrical measurements of the dispenser test adapter assembly shall be
34、 performed accordance with Method 302 of MIL-STD-202, in 4,5.2 Insulation resistance, - Electrical measurements of the dispenser test adapter assembly shall be performed in accordance with Method 302, Test Condition ?3 of MIL-STD-202. accordance with 4,4.4, subject each first article unit to the vib
35、ration requirements of MIL-STD-810, Method 514.2, Procediire X to verify conformance to 3.5.1. test, inspect each dispenser test adapter assembly for evidence of damage. Any dispenser which fails to comply to the applica- ble requirements shall be rejected. 4.5.3 Transportation vibration. - Using eq
36、uipment in Following this 4,5.4 Temperature and humidity. - Using equipment in accordance with 4.4.4, subject each first article unit to Test 105 of MIL-STD-331 to verify conformance to 3.5.2. Following this 28 day test, lower the chamber temperature to 130F minimum and allow to stabilize for a mini
37、mum of four hours. Subject the dispenser test adapter assemblies to the circuit resistance test, 4.4.3.1, and the insulation resistance test, 4.4.3.2,.at 130OF. If the test cannot be conducted in the chamber, the test shall be completed within 30 minutes maximum after removal from the chaniber. Foll
38、owing this test, place the units in a chamber at -60F for a minimum of four hours and repeat the circuit resistance and insulation resistance tests. Any item which fails to meet applicable requirements shall cause the First Article Sample to be rejected. , 5. PREPARATION FOR DELIVERY 5.1 Packing. -
39、The assemblies shall be packed as 5.2 specified on Dwg. 9322169. ance with Dwg. 9322169. Marking. - Marking of the box shall be in accord- 6. NOTES - * 15 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- I I MIL-D-63347 47 I 7777906 0252633 4 I, MIL-
40、D-63149 (AR) 6.1 Intended use - This dispenser assembly is used in testing the Aircraft General Purpose.Dispenser, M-130. 6 . 2. Ordering data - Procurement documents shall specify the following: a. b. Provisions for submission of first article C. Provisions of MIL-A-$8078, Title, number and data of
41、 this specification. samples. 6.3 Cubmissish of inspection equipment designa for approval., - (See MIL-A-48078) Submit equipment designs as required, to Commander, U.S. Army Armament Research and Development Command, ATTN: DEIDAR=QAA-I, Dover, New Jersey 07801. 6.4 Distribution of ammunit-ion data c
42、ards. - Distri- bution of data cards shall include the following: Commander, U.S. Army Armament Research and Development Command, ATTN: DRDAR-QAA-Q, Dover, New Jersey 07801. 6.5 Drawings. - Drawings listed in Section 2 of this specification under the heading US Army Armament Reserach and Development
43、 Command (ARRADCOM) may also include draw- ings prepared by, and identified as, Edgewood Arsenal, Frahkford Arsenal, Rock Island Arsenal or Picatinny Arsenal drawings . Technical data origianlly prepared by these activities is now under the cognizance of ARRADCOM. 1 Custodian: Army-AR Project Number: 4925-A-128 Preparing Activity: Army-AR auS. GOVERNMENT PRINTING OFFICE - 703-122/1004 16 i i /-y Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-