1、MIL-P-444011 36 = 7779706 04112276 2 I I INCH-POUND I MIL-P-44401(GL) 16 February 1990. MILITARY SPECIFICATION PRESS SECTION, MODULAR PRINTING SYSTEM This specification is approved for use by the Natick Research, Development, and Engineering Center, Department of-the Army, and is available for use b
2、y all Departments and Agencies of the Department of Defense. 1, SCOPE 1.1 Scope. This specification covers the press section of the Modular Printing System (see 6. i). 2, APPLICABLE DOCUMENTS 2.1 Government Documents. 2,l.l Specifications, standards, and handbooks. The following specifi- cations, st
3、andards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (s
4、ee 6.2). Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Natick Research, Development, and Engineering Center, Natick, MA 01760-5014 by using the self-adressed Standardization Document
5、 Improvement Proposal (DD Form 1426) appearing at the end of this doCuinent or by letter. AMSC N/A FSC 3610 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I SPECIFICAT
6、IONS MIL I TARY MIL-D-3464 - Desiccants, Activated, Bagged, Packaging Use and MIL-S-44195 - Shelter, Tactical, Expandable, Two-Side Static Dehumidification STANDARDS MILITARY MIL-STD-105 - Sampling Procedures and Tables for Inspection 9 by Attributes (Unless otherwise indicated, copies of the federa
7、l and military specif ica- tiens,-standards, and handbooks are available from the Standardization Documents Order Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.) .2.1,2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and p
8、ublications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. Department of the Army Technical Manuals TM 5-3610-293-13U - Operators Unit and Intermediate Direct Support Maintenance Manual Including Repair Parts a
9、nd Special Tools List for Modular Printing System, Module B - Press Section (Copies of the Army Technical Manuals are available from the U.S. AG Publications Center, 1655 Woodson Road, St. Louis, M0.63144.) DRAWINGS U.S. ARMY NATICK RESEARCH, DEVELOPMENT, AND ENGINEERING CENTER 5-4-6732 5-13-4700 5-
10、1 3-4733 5-13-4763 5-13-4946 5-13-5001 5- 13-501 O 5-13-5024 Passageway, Tent, IS0 to IS0 Press Shelter Arrangement 24,000 BTU Heat Pump 36,000 BTU Heat Pump Printing Press Stencil, Center of Gravity Modification, External Walls Shelter, Outside MODS (PRESS) 2 Provided by IHSNot for ResaleNo reprodu
11、ction or networking permitted without license from IHS-,-,-MIL-P-44401 36 m 3777706 041227 6 I 5-13-5026 - Data Plate, Transportation Data 5-13-5028 - Data Plate, Identification, Press Section (Copies of drawings are available from the U.S. Army Natick Research, Development, and Engineering Center,
12、ATTN: STRNC-EMSC, Natick, MA 01760-5014.) 2.2 Non-Government publications. The following documents forms a part of this document to the extent specified herein. of the documents which are DoD adopted are those listed in the issue of the DODISS cited in the solicitation. Unless otherwise specified, t
13、he issues of documents not listed in the DODISS are the issues of the documents cited in the solicitation (see 6.2). Unless otherwise specified, the issues NATIONAL FIRE PROTECTION ASSQCIATION NFPA No, 70 - National Electrical Code Handbook 3.2 Alternate components. Components offered as equivalent
14、to components specified hereinafter and on the referenced drawings as a specific manufacturers part or model number or equal, shall be functionally equal to the manufacturers model number identified, and of equal or better quality. The incorporation and inclusion of such a component in the design of
15、 the specified end product shall not require modification or change to any other specified component, and shall not reduce ease of maintenance to it or any other components, unless such modification or change is specifically approved by the contracting officer. Prior to manufacture of the first arti
16、cle, or if none is required, prior to commencing production, the contractor shall submit for the contracting officers approval, a list identifying each proposed alternate component, together with proof that each listed component complies with requirements specified above, The contracting officer, at
17、 his option, may require a physical sample of the proposed substitution. Approval of the submitted listing, together with the necessary supporting data, authorizes commencement of manufacture but does not relieve the contractor of responsibility that these components perform in accordance with speci
18、fied requirements when incorporated into the end product, 3 (Application for copies should be addressed to the National Fire Protection Association, 80 Battery March Pike, Quincy, MA 02169.) (Non-Government standards and other publications are normally available from the organizations that prepare o
19、f distribute the documents. may be available in or through libraries or other informational services.) These documents also 2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in th
20、is document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection (see 6.3) in accordance with 4.3. Provided by IHSNot for ResaleNo repro
21、duction or networking permitted without license from IHS-,-,-3.2.1 Materials and components. The materials and components shall be as specified herein and on the applicable drawings. Materials and components not definitely specified shall be of the quality normally used by the manufacturer provided
22、the completed item complies with all the provisions of this specifi- cation, It is encouraged that recycled material be used when practical as long as it meets the requirements of this specification. 3.3 Design and construction. The design and construction of the press section shall be as specified
23、herein, and in Drawing 5-13-4700 and all subsidiary drawings and parts lists pertaining thereto. All wiring shall be in accordance with the provisions of NFPA No, 70. 3.4 Press section operation. All electrically operated equipment, including switches, lights, telephone, press, heat pumps,and sink s
24、hall function as 1 specified when tested for performance and roadability withaut failure in 4.5 and 4.5.2. 3.5 Shelter. The shelter (see 3.9) shall be either desert sand or camouf green as specified (see 6.2). All interior and exterior surfaces of the she age ter shall be cleaned and rehabilitated w
25、hen necessary to restore the original color and finish. 3,6 Complexing kit. The complexing kit (see 3.9) shall be either desert sand or camouflage green as specified (see 6.2). Exterior surfaces shall be cleaned -and rehabilitated, when necessary to restore the original color and finish. 3.7 Technic
26、al manuals. Technical manual, 5-3610-293-13 Any test failure shall be cause for rejection of the press section tested 8 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-44401(GL) Examination shall be made of each press section 4.4.6 Packaging ex
27、amination. to determine that preservation, packing, and marking comply with section 5 requirements. Any deviation from specified requirements shall be cause for rejection of the press section. 4.5 Methods of inspection. 4.5.1 Performance test. Each completed press section shall be connected to a sui
28、table electric power source, and the heat pumps, press, sink, and electrical system (lights, switches, buttons, and outlets) shall be operated in accordance with applicable technical manuals to insure proper operation. All doors/drawers shall be checked to insure smooth operation. malfunction or any
29、 leakage in sink shall constitute failure of this test. Any electrical or mechanical 4.5.2 Roadability. Following successful completion of test specified in 4.5.1 the complete press section, with all contents, shall be secured as specified in section 5 and mounted on Government furnished mobilizers
30、and subjected to a 50 mile road test. The vehicle shall be driven at top legal speed, or as road conditions permit, for this type equipment. Not less than 10 miles of the test course shall be unimproved roads such as earth or partially surfaced gravel, and the remainder shall be improved roads such
31、as concrete, asphalt, or macadam. The test shall include not less than 20 quick starts and stops of the vehicle on grades of not less than 5 percent or greater than 10 percent. starts and stops shall be made on ascending grades and 50 percent on descending grades. At the completion of the test, the
32、press section shall be reinspected for the defects listed in table II and retested as specified in 4.5.1. nonconformance noted on completion of the road test shall constitute Eailure of the test, 50 percent of the Any 5. PACKAGING I 5.1 Preservation and packing. Preservation, packing, an marking sha
33、ll be in accordance with applicable drawings and TM 5-3610-293-13&P. to insure that desiccant conforming to MIL-D-3464, type I, has been loaded into the shelter before closing. A minimum quantity of 500 units of desiccant shall be Loaded into each shelter. Care should be taken 6, NOTES (This section
34、 contains information of a general or explanatory nature that may 6.1 Intended use. be helpful, but is not mandatory.) The press section is intended for transport to various distribution areas for use in producing sheets of printed material. The press section is one part of the Modular Printing Syst
35、em and is used in a tactical situation where early and rapid distribution of material is required by PSYOPS units. . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-6.2. Acquisition requirements. Acquisition documents should specify the following: a.
36、 Title, number, and date of this specifitation. b, Issue of DODISS to be cited in the solicitation, and if required, the c. When first article is required (see 3.1, 4.3, and 6.3). d. e. Source and delivery of Government furnished property as applicable f. When certificate of qualification test for w
37、elders is not required specific issue of individuel documents referenced (see 2.1.1 and 2.2), Color of exterior of shelter and complexing kit (see 3.6). (see 3.9). (see 3.10.1). 6.3 First article, When a first article is required, it shall be inspected The first article should be a preproduction sam
38、ple. and approved under the appropriate provisions of Federal Acquisition Regulation (FAR) 52.209. The contracting officer should specify the appropriate type of first article and the number of units to be furnished. The contracting officer should also include specific instructions in acquisition do
39、cuments regarding arrangements for selection, inspection, and approval of the first article. 6,4 Subject term (key word) listing. Imprint Impression PSYOPS Shelter, expandable Stamp Custodian: Army - GL Preparing activity: Army - GL (Project 3610-A361) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-