1、*USACE / NAVFAC / AFCESA / NASA UFGS-02 83 14.00 10 (February 2010)-Preparing Activity: USACE SupersedingUFGS-02 83 14 00 10 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION TABLE OF CONTENTSDIVISION 02 - EXISTING CONDITIONSSECTION 02
2、82 14.00 10ASBESTOS HAZARD CONTROL ACTIVITIES02/10PART 1 GENERAL1.1 PAYMENT PROCEDURES1.2 REFERENCES1.3 DEFINITIONS1.3.1 Amended Water1.3.2 Asbestos-Containing Material (ACM)1.3.3 Authorized Person1.3.4 Building Inspector1.3.5 Class I Asbestos Work1.3.6 Class II Asbestos Work1.3.7 Class III Asbestos
3、 Work1.3.8 Class IV Asbestos Work1.3.9 Clean Room1.3.10 Competent Person1.3.11 Contractor/Supervisor1.3.12 Critical Barrier1.3.13 Decontamination Area1.3.14 Demolition1.3.15 Disposal Bag1.3.16 Disturbance1.3.17 Equipment Room or Area1.3.18 Fiber1.3.19 Friable ACM1.3.20 Glovebag1.3.21 High-Efficiency
4、 Particulate Air (HEPA) Filter1.3.22 Intact1.3.23 Model Accreditation Plan (MAP)1.3.24 Negative Initial Exposure Assessment1.3.25 NESHAP1.3.26 Nonfriable ACM1.3.27 Nonfriable ACM (Category I)1.3.28 Nonfriable ACM (Category II)1.3.29 Permissible Exposure Limits (PELs)1.3.29.1 PEL-Time Weighted Averag
5、e(TWA)1.3.29.2 PEL-Excursion LimitSECTION 02 82 14.00 10 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.3.30 Regulated Area1.3.31 Removal1.3.32 Repair1.3.33 Surfacing ACM1.3.34 Thermal System Insulation (TSI) ACM1.3.35 Transite1.3.36 Worker1
6、.4 SYSTEM DESCRIPTION1.4.1 Abatement Work Tasks1.4.2 Unexpected Discovery of Asbestos1.4.3 Wallboard/Joint Compound1.5 SUBMITTALS1.6 QUALITY ASSURANCE1.6.1 Written Qualifications and Organization Report1.6.2 Specific Requirements1.6.3 Federal, State or Local Citations on Previous Projects1.6.4 Preco
7、nstruction Conference1.7 SAFETY1.7.1 Asbestos Hazard Abatement Plan Appendix1.7.2 Activity Hazard Analyses Appendix1.7.3 Local Exhaust System1.8 SECURITY1.8.1 Licenses, Permits and Notifications1.8.2 Regulated Areas1.8.3 Warning Signs and Tape1.8.4 Warning Labels1.9 MEDICAL SURVEILLANCE REQUIREMENTS
8、1.9.1 Respiratory Protection Program1.9.2 Respiratory Fit Testing1.9.3 Respirator Selection and Use Requirements1.9.4 Personal Protective Equipment1.9.5 Whole Body Protection1.9.5.1 Coveralls1.9.5.2 Gloves1.9.5.3 Foot Coverings1.9.5.4 Head Covering1.9.5.5 Protective Eye Wear1.10 HYGIENE1.10.1 3-Stag
9、e Decontamination Area1.10.2 Load-Out Unit1.10.3 Single Stage Decontamination Area1.10.4 Decontamination Area Exit Procedures1.10.5 Smoking1.11 TRAINING PROGRAMPART 2 PRODUCTS2.1 ENCAPSULANTS2.2 ENCASEMENT PRODUCTS2.3 RECYCLABLE MATERIALS2.4 EXPENDABLE SUPPLIES2.4.1 Glovebag2.4.2 Duct Tape2.4.3 Disp
10、osal Containers2.4.4 Sheet Plastic2.4.4.1 Flame Resistant2.4.4.2 Reinforced2.4.5 Mastic Removing Solvent2.4.6 Leak-tight WrappingSECTION 02 82 14.00 10 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.4.7 Viewing Inspection Window2.4.8 Wetting
11、 Agents2.4.9 Strippable Coating2.5 EQUIPMENT2.5.1 Scales2.5.2 Tools2.5.3 Rental Equipment2.5.4 Air Monitoring EquipmentPART 3 EXECUTION3.1 GENERAL REQUIREMENTS3.2 PROTECTION OF ADJACENT WORK OR AREAS TO REMAIN3.3 OBJECTS3.3.1 Removal of Mobile Objects3.3.2 Stationary Objects3.4 BUILDING VENTILATION
12、SYSTEM AND CRITICAL BARRIERS3.5 PRECLEANING3.6 METHODS OF COMPLIANCE3.6.1 Mandated Practices3.6.2 Control Methods3.6.3 Unacceptable Practices3.6.4 Class I Work Procedures3.6.5 Specific Control Methods for Class I Work3.6.5.1 Negative Pressure Enclosure (NPE) System3.6.5.2 Glovebag Systems3.6.5.3 Min
13、i-Enclosures3.6.5.4 Wrap and Cut Operation3.6.6 Class II Work3.6.7 Specific Control Methods for Class II Work3.6.7.1 Vinyl and Asphalt Flooring Materials3.6.7.2 Roofing Material3.6.7.3 Cementitious Siding and Shingles or Transite Panels3.6.7.4 Gaskets3.6.8 Specific Control Methods for Class III Work
14、3.6.9 Specific Control Methods for Class IV Work3.6.10 Methods for Asphaltic Wrap3.6.11 Class I Asbestos Work Response Action Detail Sheets3.6.12 Class II Asbestos Work Response Action Detail Sheets3.6.13 Abatement of Asbestos Contaminated Soil3.6.14 Enclosure of ACM3.6.15 Encapsulation of ACM3.6.16
15、 Combined Encapsulation of Acoustical Wall and Ceiling Plaster3.6.17 Response Action Detail Sheets for Repair of Class I Materials3.6.18 Response Action Detail Sheets for Repair of Class II Materials3.6.19 Encasement of ACM3.6.20 Sealing Contaminated Items Designated for Disposal3.7 FINAL CLEANING A
16、ND VISUAL INSPECTION3.8 LOCKDOWN3.9 EXPOSURE ASSESSMENT AND AIR MONITORING3.9.1 General Requirements3.9.2 Initial Exposure Assessment3.9.3 Negative Exposure Assessment3.9.4 Independent Environmental Monitoring3.9.5 Preabatement Environmental Air Monitoring3.9.6 Environmental Air Monitoring During Ab
17、atement3.9.7 Final Clearance Air Monitoring3.9.7.1 Final Clearance Requirements, NIOSH PCM Method3.9.7.2 Final Clearance Requirements, EPA TEM MethodSECTION 02 82 14.00 10 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.9.7.3 Air Clearance Fa
18、ilure3.9.8 Air-Monitoring Results and Documentation3.10 CLEARANCE CERTIFICATION3.11 CLEANUP AND DISPOSAL3.11.1 Title to ACM Materials3.11.2 Collection and Disposal of Asbestos3.11.3 Records and Management Plan3.11.3.1 Asbestos Waste Shipment Records3.11.3.2 Asbestos Management Plan- End of Section T
19、able of Contents -SECTION 02 82 14.00 10 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-02 83 14.00 10 (February 2010)-Preparing Activity: USACE SupersedingUFGS-02 83 14 00 10 (April 2006)UNIFIED FACILITIES
20、 GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION 02 82 14.00 10ASBESTOS HAZARD CONTROL ACTIVITIES02/10*NOTE: This guide specification covers the requirements for removal, encapsulation, enclosureencasement, or repair of friable and non-friable asbestos-containing m
21、aterial (ACM) which is encountered during the demolition, alteration, renovation, or maintenance of structures, substrates, equipment or portions thereof that contain asbestos; transportation, disposal, storage, containment of; and housekeeping activities on the site at which these activities are pe
22、rformed This specification is used in conjunction with Section 01 35 26 GOVERNMENT SAFETY REQUIREMENTS.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove infor
23、mation and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization des
24、ignation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).This guide specification includes tailoring options for (1) No Detail Sheets, (2) Class I, II, III Abatement, (3) Class II Removal, and (4) Demolition. Selection of
25、tailoring options for this Section, must be done in numerical order from (1) to (4); Option (1) includes (2), (3) and (4); option (2) includes (3) and (4) etc. Editing of each option (punctuation, paragraph numbers, proper listing sequences, etc.) to fit the project is still SECTION 02 82 14.00 10 P
26、age 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-required.*PART 1 GENERAL*NOTE: This specification includes asbestos abatement activities and requirements in accordance with 40 CFR Part 61, Subpart M (USEPA); Class I, Class II, Class III, and Cla
27、ss IV abatement operations per 29 CFR 1926.1101 (OSHA); training requirements in accordance with OSHA 29 CFR 1926.1101and 40 CFR 763 (USEPA); selectable optional air monitoring requirements in accordance with 40 CFR 763; and is supplemented by Engineer Pamphlet (EP) 1110-1-11, “Asbestos Abatement Gu
28、ideline Detail Sheets“. This specification has been developed to be used with a comprehensive set of Asbestos Abatement Detail Sheets in EP 1110-1-11. The EP provides guidance instructions on the selection and use of 2 types of Detail Sheets: SET-UP DETAILS (describing the containment and control me
29、thods to be used) and RESPONSE ACTION DETAILS (describing the abatement technique to be employed (removal, encapsulation, encasement, enclosure or repair) and the specific work task item to be abated (ex. removal of acoustical ceiling plaster). Each RESPONSE ACTION DETAIL references the applicable S
30、ET-UP DETAIL to be used. All Detail Sheets are identified by numeric designation. Each individual asbestos abatement work task, to include pertinent information for the task and the appropriate Detail Sheets, will be summarized at paragraph DESCRIPTION OF WORK and Table 1, and will not have to be re
31、peated in this paragraph.The designer must be an EPA/State Certified/Licensed Asbestos Project Designer.The material and equipment required for each project are very dependent upon the abatement containment andcontrol requirements (SET-UP DETAILS) to be used (RESPONSE ACTION DETAIL). Edit the materi
32、als and equipment paragraphs accordingly. Ensure that all necessary materials and equipment are specified.The limits of asbestos abatement must be indicated on project drawings and in the specification in sufficient detail for the Contractor to submit an accurate bid. In addition, the project drawin
33、gs will clearly show the asbestos abatement information required on the Note to paragraph DESCRIPTION OF WORK for Table 1, and where the limits of asbestos abatement will impact non-asbestos abatement work activities or interface with new work.Demolition and/or renovation of structures that contain
34、nonfriable Category I or II ACM that would be left in place during demolition is governed by 40 SECTION 02 82 14.00 10 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-CFR Part 61 and state requirements. The USEPA has published guidance document
35、s that will assist in this decision process. They include EPA 340/1-92/010(1992), “Guidelines for Catastrophic Emergency Situations Involving Asbestos“; 340/1-92/013(1992), “A Guide to Normal Demolition Practices Under the Asbestos NESHAP“; and EPA document dated 1994, “Asbestos/NESHAP Demolition De
36、cision Tree“. Consult with the USEPA regional office, USEPA regulations, state regulator and state requirements, and the Army guidance referenced in EP 1110-1-11 for the specific survey, assessment and decision steps to take prior to making a decision to leave nonfriable ACM in-place during building
37、 demolition, or to remove it prior to demolition. Friable ACM shall always be removed prior to any building demolition.The USEPA has delegated the responsibility of approving landfills for the disposal of asbestos to most states. Verify with the state in which the project is located whether the stat
38、e, USEPA, region, or local agency has jurisdiction and what the requirements are.For OSHA Class I asbestos abatement operations that involve the abatement of less than 1 square meter (10 square feet) or 8 linear meters (25 linear feet); Class II operations; Class III operations; or outdoor abatement
39、 operations; an enclosed containment regulated area (to include full containment, single or double bulkhead containment, or mini-containment) may not be required. The location of the item to be abated, type of material, and potential hazard must be reviewed and a judgment made by the designer as to
40、whether or not a modified containment area, glovebag, or outdoor technique may be safely used. In a case where an enclosed containment regulated area is not required, many of the provisions in this specification should be deleted.Confer with the Contracting Officer to determine if a special clause w
41、ill be prepared and included for Contractor pre-qualification (see EP 1110-1-11) requirements.The designer will not specify the use of any replacement material that contains asbestos.*1.1 PAYMENT PROCEDURES*NOTE: Remove this subparagraph when not required or edit accordingly.*Submit copies of weight
42、 bills and delivery tickets for payment to the SECTION 02 82 14.00 10 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Contracting Officer during the progress of the work. Furnish scale tickets for each load of ACM weighed and certified. These t
43、ickets shall include tare weight; identification mark for each vehicle weighed; and date, time and location of loading and unloading. Tickets shall be furnished at the point and time individual trucks arrive at the worksite. A master log of all vehicle loading shall be furnished for each day of load
44、ing operations. Before the final statement is allowed, file with the Contracting Officer certified weigh bills and/or certified tickets and manifests of all ACM actually disposed by the Contractor for this contract.1.2 REFERENCES*NOTE: This paragraph is used to list the publications cited in the tex
45、t of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification