1、*USACE / NAVFAC / AFCESA / NASA UFGS-10 22 39 (May 2011)-Preparing Activity: USACE Superseding without revisionUFGS-10 22 26.33 (August 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION TABLE OF CONTENTSDIVISION 10 - SPECIALTIESSECTION 10 22 3
2、9FOLDING PANEL PARTITIONS05/11PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.2.1 Manual Operation1.2.2 Electric Operation1.2.3 Performance Requirements1.2.3.1 Fire Endurance1.2.3.2 Laboratory Acoustical Requirements1.3 SUBMITTALS1.4 SUSTAINABLE DESIGN CERTIFICATION1.5 DELIVERY, STORAGE, AND HAN
3、DLING1.6 WARRANTYPART 2 PRODUCTS2.1 MATERIALS2.2 FOLDING PANEL PARTITIONS2.2.1 Panels2.2.2 Finish Covering2.2.3 Track2.2.4 Suspension System2.2.5 Tackboard2.2.6 Markerboards2.3 ACCESSORIES2.3.1 Doors2.3.2 Ceiling Guards2.3.3 Metal Soffit2.4 SEALS AND SWEEPSTRIPS2.5 ELECTRICAL OPERATORS2.6 COLORPART
4、3 EXECUTION3.1 INSTALLATION3.1.1 Preparation WorkSECTION 10 22 39 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.1.2 Electrical Operators3.1.3 Adjustment3.2 FIELD TESTS3.2.1 Operational Test3.2.2 Visual Test3.2.3 Acoustical Test3.3 CLEANING-
5、 End of Section Table of Contents -SECTION 10 22 39 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-10 22 39 (May 2011)-Preparing Activity: USACE Superseding without revisionUFGS-10 22 26.33 (August 2010)UNI
6、FIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION 10 22 39FOLDING PANEL PARTITIONS05/11*NOTE: This guide specification covers the requirements for folding panel partitions.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format St
7、andard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information an
8、d requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: Designer should require materials, products,
9、and innovative construction methods and techniques which are environmentally sensitive, take advantage of recycling and conserve natural resources.Associated work found in other sections includes:Steel supporting members or hanger rods, Section 05 50 13 MISCELLANEOUS METAL FABRICATIONS.Wood blocking
10、, rough bucks, and headers, Section 06 10 00 ROUGH CARPENTRY.Wood trim, wood or hardboard ceiling guard, or soffits, Section 06 20 00 FINISH CARPENTRY.SECTION 10 22 39 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Lock cylinders, Section 08 7
11、1 00 DOOR HARDWARE.Operator field connections to power sources and inner connection to control switches, Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM.The following information should be shown on the drawings:1. Location, size, and folding area of folding panel partitions.2. Direction of operation,
12、header conditions indicating height, track anchorage, track channel, and jamb conditions.3. Partition supporting structure. The structural support for the partition is not part of this section; it must be indicated and specified separately.4. A schedule of folding panel partitions by type (manually
13、or electrically operated), sizes, and stack space and identified by mark number or letter5. For electrically operated partitions, show power source and desired switch location.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publ
14、ications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Referen
15、ce Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed belo
16、w form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM A653/A653M (2010) Standard Specification for Steel SECTION 10 22 39 Page 4Provided by IHSNot for ResaleNo reproduction or network
17、ing permitted without license from IHS-,-,-Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM B 221 (2008) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and TubesASTM B 221M (2007) Standard Specification f
18、or Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)ASTM C 423 (2009a) Sound Absorption and Sound Absorption Coefficients by the Reverberation Room MethodASTM D 751 (2006) Coated FabricsASTM E 336 (2010) Measurement of Airborne Sound Insulation in BuildingsASTM E 41
19、3 (2010) Rating Sound InsulationASTM E 557 (2000; R 2006e1) Installation of Operable PartitionsASTM E 84 (2010b) Standard Test Method for Surface Burning Characteristics of Building MaterialsASTM E 90 (2009) Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Build
20、ing Partitions and ElementsCHEMICAL FABRICS TIA 09-1; TIA 09-2) Life Safety CodeNFPA 252 (2008) Standard Methods of Fire Tests of Door AssembliesNFPA 286 (2011) Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire GrowthNFPA 70 (2011) National E
21、lectrical CodeSCIENTIFIC CERTIFICATION SYSTEMS (SCS)SCS Scientific Certification Systems SECTION 10 22 39 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-(SCS)Indoor AdvantageUNDERWRITERS LABORATORIES (UL)UL 10B (2008; Reprint Apr 2009) Fire Te
22、sts of Door Assemblies1.2 SYSTEM DESCRIPTION*NOTE: The designer will edit this specification for manual or electric operation of folding panel partitions as required for the project.*a. No less than 30 calendar days prior to the scheduled commencement of installation, submit the following to the Con
23、tracting Officer:Manufacturers QualificationsManufacturers Sample WarrantyStatement of Code ComplianceStatement of Standards ConformityVerification of Field MeasurementsExisting Electrical DataFabrication DrawingsInstallation Instructionsb. Supply and install manual and electric operation, acoustica
24、l folding panel partitions, factory finished, supported from overhead track without with floor guides, as shown on the drawings including all hardware, seals, track and rollers as needed to close the specified opening.c. Submit drawings to demonstrate that the system has been coordinated and will pr
25、operly function as a unit. Show layout of the work; track and jamb fastening methods; seal and installation details; and equipment relationship to other parts of the work including clearances for maintenance and operation.1.2.1 Manual OperationThe manual operation shall be a force no greater than 89
26、 _ N 20 _ lbf to start movement at the rate of 1.02 m/s 3.33 ft/s (200 ft/min). Use a removable handle to extend and retract the bottom operable seals; vertical movement of seals shall be 50 _ mm 2 _ inches. Closure to the lead wall shall be by use of a flexible bulb; accomplish final closing by mea
27、ns of a lever exerting pressure against the wall.1.2.2 Electric OperationDesign the pressure-sensitive leading edge so that a force of 17.8 _ N 4 _ lbf will stop the forward motion; system shall stop the partition movement if people or objects are in the path of the partition when it is being extend
28、ed or in the pocket area when the panels are being folded. Provide a weight-sensitive floor mat in the storage pocket to prevent partition movement with as little as 2.3 kg 5 lbs of weight applied. Wall mount the electric control.SECTION 10 22 39 Page 6Provided by IHSNot for ResaleNo reproduction or
29、 networking permitted without license from IHS-,-,-1.2.3 Performance Requirements1.2.3.1 Fire Endurance*NOTE: Select flame spread and smoke developed criteria to suit project.*For partitions more than 5.6 square meters 60 square feet in area, provide covering and lining with flame spread rating of 2
30、5 or less, fuel contribution rating of 15 or less, smoke generation of 50 or less in accordance with NFPA 101 when tested in accordance with ASTM E 84. 1 hour fire rating, UL 10B, or NFPA 252. Submit flame and smoke development testsreports. Provide door and partition finishes with a Class A rating
31、when tested in accordance with ASTM E 84.1.2.3.2 Laboratory Acoustical Requirements*NOTE: Specify sound transmission class as determined by project requirements. The requested rating should be between 35 and 54 STC. 39 and 40 STC are widely available. If more is required, another type of moveable pa
32、rtition should be used. Specify a panel weight of no less than 14 kg per square meter (3 psf) for STC of 35, 24 kg per square meter (5 psf) for STC of 45.*Provide partitions tested in accordance with ASTM E 90, by a laboratory accredited by the U.S. Bureau of Standards, that have attained a sound tr
33、ansmission class (STC) of not less than 39 40 _ in a fully extended position, with a Noise Reduction Coefficient (NRC) of 0.25-0.30 for napped, tufted or looped fabric 0.65-0.75 for perforated steel in accordance with ASTM C 423 _. Partition tested shall be of the same construction, materials, and m
34、odel number as the partition to be provided and be fully operable. Test specimen shall be not less than 12 square meters in area 4200 by 2700 mm 126 square feet in area 14 feet by 9 feet. Panel weight shall be a minimum of 26 kg/square meter 5.5 psf for STC up to 40, 36 kg/square meter 7.5 psf for S
35、TC up to 45, and 41 kg/ square meter 8.5 psf for STC up to 50, 48 kg/square meter 10.0 psf for STC up to 53. Design panel thickness (100 mm 4 inch nominal) and composition to provide the required STC rating in accordance with ASTM E 90 and ASTM E 413.1.3 SUBMITTALS*NOTE: Review submittal description
36、 (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Govern
37、ment approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not SECTION 10 22 39 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-complex and can be reviewed through the Contractors Quality
38、Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving
39、 authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following
40、the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ desig
41、nation are for Contractor Quality Control approval. information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-01 Preconstruction Su
42、bmittalsManufacturers Qualifications; G; G, _Manufacturers Sample WarrantyStatement of Code Compliance; G; G, _Statement of Standards Conformity; G; G, _Verification of Field Measurements; G; G, _ Existing Electrical DataSD-02 Shop DrawingsInstallation; G; G, _Wiring Diagrams; G; G, _Layouts; G; G,
43、_Fabrication Drawings; G; G, _SD-03 Product DataFolding Panel Partitions; G; G, _Installation Instructions; G; G, _CertificationSD-04 SamplesFolding Panel Partitions; G; G, _SD-06 Test ReportsAcoustical Test; G; G, _SECTION 10 22 39 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Flame and Smoke Development Tests; G; G, _SD-07 CertificatesMaterials; G; G, _Folding Panel Partitions; G; G, _SD-10 Operation and
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1