1、*USACE / NAVFAC / AFCESA / NASA UFGS-32 31 13.53 (April 2008)-Preparing Activity: USACE SupersedingUFGS-32 31 13.53 (January 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2008*SECTION TABLE OF CONTENTSDIVISION 32 - EXTERIOR IMPROVEMENTSSECTION 32 31
2、13.53HIGH-SECURITY CHAIN LINK FENCES AND GATES04/08PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 QUALITY ASSURANCE1.3.1 Required Report Data1.3.2 Assembly and Installation Drawings1.4 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 FENCE FABRIC2.1.1 General2.1.2 Approval Of Polyvinyl Chloride-Coat
3、ed Fence Materials2.2 POSTS2.2.1 Metal Posts for Chain Link Fence2.2.2 Accessories2.3 BRACES AND RAILS2.4 WIRE2.4.1 Wire Ties2.4.2 Barbed Wire2.4.3 Tension Wire2.5 BARBED TAPE2.6 CONCRETE2.7 GATES2.7.1 Gate Assembly2.7.2 Gate Leaves2.7.3 Gate Hardware and Accessories2.8 Turnstiles2.9 PADLOCKS2.10 GA
4、TE OPERATOR2.11 ELECTRO-MECHANICAL LOCKSPART 3 EXECUTION3.1 FENCE INSTALLATIONSECTION 32 31 13.53 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.1.1 Line and Grade3.1.2 Excavation3.1.3 Concrete Slabs and Walls3.2 POST INSTALLATION3.2.1 Earth
5、 and Bedrock3.2.2 Concrete Slabs and Walls3.3 RAILS3.4 FABRIC INSTALLATION3.5 SUPPORTING ARMS3.6 BARBED TAPE INSTALLATION3.7 GATE INSTALLATION3.8 GROUNDING3.9 SECURITY3.10 CLEANUP- End of Section Table of Contents -SECTION 32 31 13.53 Page 2Provided by IHSNot for ResaleNo reproduction or networking
6、permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-32 31 13.53 (April 2008)-Preparing Activity: USACE SupersedingUFGS-32 31 13.53 (January 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2008*SECTION 32 31 13.53HIGH-SECURITY CH
7、AIN LINK FENCES AND GATES04/08*NOTE: This guide specification covers the requirements for chain link fence for high security applicationsEdit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable item(s) or insert app
8、ropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.This guide specification includes tailoring options for NAVFAC and USACE. Selection or deselection of a tailoring option (select view-tailoring options) will include or ex
9、clude that option in the section. Specific project editing is still required for the resulting section.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organizat
10、ion designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR)*PART 1 GENERAL*NOTE: Where special fencing requirements exist, such as wolf-proofing, antiburrowing provisions, crossing drainage ditches, provisions for elec
11、trical installations, or special security installations, modify specifications and appropriate details included on the drawings. Modifications and details must afford security equal to that of the fence.SECTION 32 31 13.53 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted wi
12、thout license from IHS-,-,-Where special entrance security requirements exist such as electronic locks, motor operated gates, closed circuit video; add details and modify the specification accordingly.Use Section 32 31 13 for CHAIN LINK FENCES AND GATES. Use Section 32 31 26 for WIRE FENCES AND GATE
13、S, formerly referred to as “Farm Style Fencing“ within UFGS.NOTE: Certain types of security fence must meet the requirements of an applicable OPNAVINST. Edit this specification as needed for the type of fencing required.Standard drawings STD 872-90-02 through 872-90-13 of fence and gate types requir
14、ed will be included as part of the contract drawings; the standard drawings are available at https:/pdc.usace.army.mil/library/drawings/fence.Show layout of fence including types and locations of gates, and gate sizes. Indicate on drawings the extent of clearing required.*1.1 REFERENCES*NOTE: This p
15、aragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a R
16、ID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification wh
17、en you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM A 116 (2005) Standard Specificati
18、on for SECTION 32 31 13.53 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Metallic-Coated, Steel Woven Wire Fence FabricASTM A 121 (2007) Standard Specification for Metallic-Coated Carbon Steel Barbed WireASTM A 153/A 153M (2005) Standard Spec
19、ification for Zinc Coating (Hot-Dip) on Iron and Steel HardwareASTM A 176 (1999; R 2004) Standard Specification for Stainless and Heat-Resisting Chromium Steel Plate, Sheet, and StripASTM A 392 (2007) Standard Specification for Zinc-Coated Steel Chain-Link Fence FabricASTM A 478 (1997; R 2008) Stand
20、ard Specification for Chromium-Nickel Stainless Steel Weaving and Knitting WireASTM A 491 (2007) Standard Specification for Aluminum-Coated Steel Chain-Link Fence FabricASTM A 666 (2003) Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate and Flat BarAST
21、M A 702 (1989; R 2006) Standard Specification for Steel Fence Posts and Assemblies, Hot WroughtASTM A 780 (2001; R 2006) Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized CoatingsASTM A 824 (2001; R 2007) Standard Specification for Metallic-Coated Steel Marcelled Tensi
22、on Wire for Use With Chain Link FenceASTM B 117 (2007a) Standing Practice for Operating Salt Spray (Fog) ApparatusASTM C 94/C 94M (2007) Standard Specification for Ready-Mixed ConcreteASTM F 1043 (2008) Strength and Protective Coatings on Metal Industrial Chain-Link Fence FrameworkASTM F 1083 (2008)
23、 Standard Specification for Pipe, Steel, Hot-Dipped Zinc Coated (Galvanized) Welded, for Fence StructuresASTM F 1184 (2005) Industrial and Commercial Horizontal Slide GatesASTM F 567 (2007) Standard Practice for Installation of Chain Link FenceSECTION 32 31 13.53 Page 5Provided by IHSNot for ResaleN
24、o reproduction or networking permitted without license from IHS-,-,-ASTM F 626 (2008) Standard Specification for Fence FittingsASTM F 668 (2007) Poly(Vinyl Chloride) (PVC) and other Organic Polymer-Coated Steel Chain-Link Fence FabricASTM F 883 (2004) PadlocksASTM F 900 (2005) Industrial and Commerc
25、ial Swing GatesU.S. GENERAL SERVICES ADMINISTRATION (GSA)FS RR-F-191 (Rev K) Fencing, Wire and Post Metal (and Gates, Chain-Link Fence Fabric, and Accessories)FS RR-F-191/1 (Rev D) Fencing, Wire and Post, Metal (Chain-Link Fence Fabric)FS RR-F-191/2 (Rev D) Fencing, Wire and Post, Metal (Chain-Link
26、Fence Gates)FS RR-F-191/3 (Rev D) Fencing, Wire and Post, Metal (Chain-Link Fence Posts, Top Rails and Braces)FS RR-F-191/4 (Rev D) Fencing, Wire and Post, Metal (Chain-Link Fence Accessories)1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES
27、and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G
28、”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code
29、 of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organizatio
30、n in the District Office); “AO“ for Area Office; “RO“ for SECTION 32 31 13.53 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and
31、NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.infor
32、mation only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsFence InstallationInstallation DrawingsLocation of gate, corne
33、r, end, and pull postsGate AssemblyTurnstilesGate Hardware and AccessoriesInstallation drawings in accordance with paragraph titled, “ASSEMBLY AND INSTALLATION DRAWINGS“ of this section.SD-03 Product DataFence InstallationGate AssemblyGate Hardware and AccessoriesManufacturers catalog data.SD-04 Sam
34、plesFabricPostsPost CapsBracesLine PostsSleevesTop RailBottom RailTension WireBarbed WireBarbed Wire Supporting ArmsBarbed TapeStretcher BarsGate PostsGate Hardware and AccessoriesTurnstilesPadlocksWire TiesSamples as described within this section.SECTION 32 31 13.53 Page 7Provided by IHSNot for Res
35、aleNo reproduction or networking permitted without license from IHS-,-,-SD-06 Test Reports*NOTE: Require test reports where closer product control is essential or where difficulty might be encountered determining quality of supplied materials.*Weight in gramsounces for zinc coatingThickness of PVC c
36、oatingChemical composition and thickness of aluminum alloy coatingSD-07 CertificatesChain Link FenceSubmit reports, signed by an official authorized to certify on behalf of the manufacturer, attesting that the chain link fence and component materials meet the specified requirements.Zinc CoatingPVC c
37、oatingaluminum alloy coatingFabricBarbed WireStretcher BarsGate Hardware and AccessoriesConcreteGATE OPERATORSD-08 Manufacturers InstructionsSubmit Manufacturers instructions for the following items:Fence InstallationGate AssemblyHardware AssemblyAccessoriesSD-10 Operation and Maintenance DataElectr
38、o-Mechanical LocksGate OperatorSubmit operating and maintenance instructions1.3 QUALITY ASSURANCE1.3.1 Required Report DataSubmit reports of chain-link fencing listing and accessories regarding weight in grams ounces for zinc coating, thickness of PVC coating, and chemical composition and thickness
39、of aluminum alloy coating. Submit reports demonstrating full compliance with the following standards: FS RR-F-191, FS RR-F-191/1, FS RR-F-191/2, FS RR-F-191/3, and FS RR-F-191/4SECTION 32 31 13.53 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,
40、-1.3.2 Assembly and Installation DrawingsSubmit complete Fence Installation Drawings for review and approval by the Contracting Officer prior to shipment. Drawing details shall include, but are not limited to: Fence Installation, Location of gate, corner, end, and pull posts, Gate Assembly, Turnstil
41、es, and Gate Hardware and Accessories.1.4 DELIVERY, STORAGE, AND HANDLINGDeliver materials to site in an undamaged condition. Store materials off the ground to provide protection against oxidation caused by ground contact.PART 2 PRODUCTS2.1 FENCE FABRIC*NOTE: In salt-laden or corrosive industrial at
42、mosphere, either Class 2 fabric with 610 grams (2.0 ounces) of zinc coating per square meter (foot) or Type I, aluminum-coated fabric, will be specified. In other areas, Class 1 with 370 grams (1.2 ounces) of zinc coating per square meter (foot) or Type I will be specified. Class 2b polyvinyl chlori
43、de-coated steel fabric may be specified for other than security purposes when esthetics is of prime importance and the additional cost is justified. Fabric height must be as shown on the contract drawings. Minimum fabric height must be 1.83 m (6 feet) for controlled areas and 2.13 m (7 feet) for res
44、tricted areas. Certain security applications require fabric to be embedded into the ground or into a concrete curb.*2.1.1 GeneralProvide ASTM A 392, Class 1 Class 2, zinc-coated steel wire with minimum coating weight of 370 610 grams 1.2 2.0 ounces of zinc per square meter foot of coated surface, ASTM A 491, Type I, aluminum-coated steel wire. Class 2b polyvinyl chloride-coated steel fabric with 92 grams 0.3 ounces of zinc coating per square meter foot in accordance with ASTM F 668. Fabricate fence fabric of 9 gauge wire w