1、ASD STANDARD NORME ASD ASD NORM prEN 4645-001 Edition P 1 September 2008 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATIONAvenue de Tervuren, 270 - B-1150 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 763 3565 - www.asd-stan.orgICS: Descriptors: ENGLISH VERSIO
2、N Aerospace series Connectors, optical, circular, single and multipin, coupled by threaded ring, self-locking 1,25 mm diameter ferrule with removable alignment sleeve holder Part 001: Technical specification Srie arospatiale Connecteurs optiques circulaires accouplement par bague filete, auto-freina
3、nte ferrule 1,25, quips dun porte sleeve dmontable Partie 001 : Spcification technique Luft- und Raumfahrt Optische Rundsteckverbinder mit Schraubkupplung, selbstsichernd Ferrulendurchmesser 1,25 mm, demontierbarer Zentrierhlsenhalter Teil 001 : Technische Lieferbedingungen This “Aerospace Series“ P
4、restandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member
5、 comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, it
6、 will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by
7、 withdrawing any national standards conflicting with the EN. Edition approved for publication 30 September 2008 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2008 by ASD-STAN prEN 4645-001:2008 2 Contents Page Foreword2 Introduction.3
8、 1 Scope 3 2 Normative references 3 3 Terms and definitions .4 4 Description .4 5 Design.6 6 Definition drawings and masses7 7 Tests23 8 Quality assurance29 9 Designation and marking34 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inqui
9、ries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. prEN 4645-001:20083 Introduction This family of fiber optic connectors is derived from MIL-DTL-38999 series III and EN 3645-001. It is
10、 suitable for use on aerospace onboard applications. It provides easy access for optical contact end face cleaning. Standards for optical contacts are defined in EN 4639-002. The connectors with shell size 11 and 13 are 100 % scoop proof. The optical contacts are capable of accepting single cable si
11、zes up to a maximum of 2 mm outside diameter. 1 Scope This standard specifies the general characteristics, the conditions for qualification, acceptance and quality assurance, as well as the test programs and groups for threaded ring coupling circular fiber optic self-locking connectors, fire-resista
12、nt or non fire-resistant, intended for use in a temperature range from 65 C to 150 C continuous. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest
13、edition of the referenced document (including any amendments) applies. ISO/R 68:1973, ISO general purpose screw threads Basic profile. ISO/R 261:1973, ISO general purpose metric screw threads General plan. ISO/R 262:1973, ISO general purpose metric screw threads Selected sizes for screws, bolts and
14、nuts. ISO/R 965:1973, ISO general-purpose metric screw threads Tolerances Part 1: Principles and basic data. EN 2591-100*, Aerospace series Elements of electrical and optical connection Test methods Part 100: General. EN 3197, Aerospace series Installation of aircraft electrical and optical intercon
15、nection systems. 1) EN 3645-001, Aerospace series Connectors, electrical, circular, scoop-proof, triple start threaded coupling, operating temperature 175 C or 200 C continuous Part 001: Technical specification. EN 4531-002, Aerospace series Connectors, optical, circular, single and multipin, couple
16、d by threaded ring Flush contacts Part 002: Specification of performance and contact arrangements. EN 4639-002, Aerospace series Connectors, optical, rectangular, modular, multicontact, 1,25 mm diameter ferrule, with removable alignment sleeve holder Part 002: List of product standards. EN 4639-101,
17、 Aerospace series Connectors, optical, rectangular, modular, multicontact, 1,25 mm diameter ferrule, with removable alignment sleeve holder Part 101: Optical contact for cable EN 4641-100 Operating temperature between 65 C and 152 C Product standard. * And all parts quoted in this standard. 1) Publi
18、shed as ASD Prestandard at the date of publication of this standard. prEN 4645-001:20084 EN 4639-102, Aerospace series Connectors, optical, rectangular, modular, multicontact, 1,25 mm diameter ferrule, with removable alignment sleeve holder Part 102: Optical contact for cable EN 4641-102 Operating t
19、emperature between 55 C and 100 C Product standard. EN 4645-003, Aerospace series Connectors, optical, circular, single and multipin, coupled by threaded ring, self-locking 1,25 mm diameter ferrule with removable alignment sleeve holder Part 003: Square flange receptacle Product standard. 1)EN 4645-
20、004, Aerospace series Connectors, optical, circular, single and multipin, coupled by threaded ring, self-locking 1,25 mm diameter ferrule with removable alignment sleeve holder Part 004: Jam nut receptacle Product standard. 1)EN 4645-005, Aerospace series Connectors, optical, circular, single and mu
21、ltipin, coupled by threaded ring, self-locking 1,25 mm diameter ferrule with removable alignment sleeve holder Part 005: Plug Product standard.1)EN 9133, Aerospace series Quality management systems Qualification procedure for aerospace standard parts. MIL-DTL-38999, connector, electrical circular, m
22、iniature, high density quick disconnect (bayonet, threaded and breech coupling), environment resistant, removable crimp and hermetic solder contacts, general specification for. 2)MIL-STD-1373, Screw thread, modified, 60, stub, double. 2)3 Terms and definitions For the purposes of this document, the
23、terms and definitions are given in EN 2591-100 apply. 4 Description This document describe optical connector arrangements for plug and receptacle housings. Plug and receptacle housings conform to EN 3645-001 standard. The connectors use rear removable optical contacts with a ferrule diameter of 1,25
24、 mm. The receptacles connector with male arrangement as specified EN 4645-003 and EN 4645-004. The plug connector with female arrangement as specified EN 4645-005. The female arrangement is equipped of a removable alignment sleeve holder as specified EN 4645-005. The sleeve holder is delivered with
25、the female arrangement. It is considered as a part of the female arrangement (specific design per manufacturer). 2) Published by: Department of Defense (DoD), the Pentagon, Washington, DC 20301, USA. prEN 4645-001:2008 5 The sleeve holder can be supplied separately only for repair purpose. The conne
26、ctors are polarized by means of keyways and keys; polarization is obtained before the male contacts enter the insert of the female contacts and before the coupling ring is engaged. The position of the keying arrangement is given in EN 3645-001. The visual check of coupling is obtained by masking of
27、a red coloured band on the receptacle. 4.1 Receptacle The receptacle may be attached by: square flange; jam nut. The receptacle contains five keyways in which the keys of the plug engage. The main keyway is fixed and is wider than the others. Polarization is ensured by the different positions which
28、the secondary keyways may take. The position of the insert is fixed relative to the main keyway. 4.2 Plug The plug contains five keys which engage in the keyways of the receptacle. The main key is wider than the others. Polarization is ensured by the different positions which the secondary keys may
29、take. The position of the insert is fixed relative to the main key. The coupling ring permanently fitted on the plug enables the connectors to be coupled and uncoupled. The mating torque shall be lower than the unmating torque. The internal thread of the coupling ring may be treated with a suitable
30、lubricant compatible with the performance required in this standard. 4.3 Materials and surface treatment When dissimilar metals are in close contact, adequate protection against corrosion shall be used for the electromotive force of the cell not to exceed 0,25 V (see EN 3197). 4.3.1 Housings The mat
31、erial of the connector housings and fittings shall be of suitable material protected against corrosion by passivation, nickel or cadmium plating (see EN 3197) as specified in the product standard. 4.3.2 Optical contacts and alignment sleeves The material of the optical contacts and alignment sleeves
32、 shall be of suitable materials as specified in the product standard. The optical contacts in both plug and receptacle are sprung-loaded. The spring force is defined in the product standard. prEN 4645-001:20086 4.3.3 Metallic or non-metallic materials The materials used for insert, seals and grommet
33、s shall have hardness and mechanical characteristics consistent with the required use. The material used for guiding pins shall have hardness and mechanical characteristics consistent with the required use. 5 Design 5.1 Housings The connector housings shall be in one unit. They contain teeth at the
34、rear over the entire periphery and shall accommodate the cable outlets and other fittings. The receptacle shall be fitted with a seal for sealing the coupled housings. The jam nut receptacle housing shall contain an O-ring seal (panel seal). The lock nut shall be provided with wire locking holes. Th
35、reads shall conform to standards ISO/R 68:1973, ISO/R 261:1973, ISO/R 262:1973 and ISO/R 965:1973, except for the triple start threads, which shall conform to standard MIL-STD-1373. The coupling ring shall be designed so that the optical contacts engage when it is screwed clockwise and disengage whe
36、n it is unscrewed counter clockwise. The coupling ring shall be designed to provide a hand grip profile. Full locking of the connectors shall occur at approximately 360. On completion of tightening of the coupling ring, mechanical contact shall exist between the receptacle and plug shells. Masking o
37、f a red colour band on the receptacle shall show that the connectors are correctly mated. The front face of the plug shell shall seal when fully mated with the receptacle connector. 5.2 Inserts The insert carrying the optical contacts shall be in hard material and have a cross section and radii such
38、 that no cracks, flaking or breaks can occur in normal operation. The insert for contacts shall be non-removable; it shall be mechanically held in the housing. Sealing shall be provided between the housing and insert. The mechanical contacts retention system shall be integrated in the hard insert. T
39、he design shall permit individual installation of the contacts without removal of the connector. Fitting and removal of the contacts shall be from the rear. For ease of operation, tools as per MIL-I-81969/1-03 standard (P/N for size 16) may be used. Contact position identification shall be permanent
40、 and contrasted on the rear and the front face of the insert or grommet. The female insert (mounted into the plug connector), including the sleeve holder, shall incorporate two alignment pins for multiway connectors. The male insert (mounted into the receptacle connector) shall incorporate two align
41、ment holes for multiway connectors. prEN 4645-001:2008 7 5.3 Removable sleeve holder The removable sleeve holder must be assembled onto the plug connector. 6 Definition drawings and masses The general dimensions and the masses of receptacles, plugs and protective covers are given in the product stan
42、dards. 6.1 Receptacle mating dimensions 6.1.1 Receptacle with male insert The mating dimensions of receptacles with the male insert are shown in Figure 1 for shell size 11, 13, 15, 17, 19, 21, 23 and 25 and in Table 1. Dimensions and tolerances are in millimetres. prEN 4645-001:20088 Key 1 Initial c
43、ontact with static seal. 2 Optical contact rear limit stop onto the insert 3 Alignment pin hole 4 Unmated position 5 Mechanical bottom of the receptacle onto the plug. NOTE Other dimensions are in accordance with EN 3645-001 standard. Figure 1 Table 1 Housing size A Gask loc B 11 1,615 1,565 13 15 1
44、7 19 21 23 25 14,73 14,50 2,20 2,15 prEN 4645-001:2008 9 6.2 Plug mating dimensions 6.2.1 Plug with female insert The mating dimensions of plugs with the female insert are shown in Figure 2 for shell size 11, 13, 15, 17, 19, 21, 23 and 25 and in Table 2. Dimensions and tolerances are in millimetres.
45、 Key 1 Mechanical bottom of the receptacle onto the plug. 2 Optical contact rear limit stop onto the insert 3 Alignment pins 4 Unmated position 5 Detail of the 2 alignment pins extremity. 6 Detail of the alignment sleeve holder cavities. 7 Alignment sleeve extremity NOTE Other dimensions are in acco
46、rdance with EN 3645-001 standard. Figure 2 prEN 4645-001:200810 Table 2 Housing size B max. 11 1,405 13 15 17 19 21 23 25 2,015 6.3 Displacement of the optical contact in the female insert 6.3.1 Receptacle with female insert and plug with male insert The displacement of the optical contact in the fe
47、male insert is shown on Figure 3. Dimensions and tolerances are in millimetres. Key 1 Plug/Receptacle mechanical bottoming Figure 3 1 prEN 4645-001:2008 11 6.3.2 Coupling contact condition See Figure 4. Key 1 Optical contact to sleeve holder stop 2 Sleeve cavity inner diameter 3 Sleeve to sleeve hol
48、der cavity stop 4 Sleeve outer diameter Condition in every case, J 0 The different shapes and dimensions of the sleeve cavity must be defined to warranty this condition. Figure 4 6.4 Receptacle and plug polarization See Figure 5. Dimensions and tolerances are in millimetres. prEN 4645-001:200812 Rec
49、eptacle Plug NOTE All dimensions are in accordance with EN 3645-001 standard. Figure 5 6.4.1 Dimensions of the rear part The dimensions of the rear part of receptacles and plugs with threads for mounting accessories are shown in Figure 6 and Table 3. Figure 6 prEN 4645-001:2008 13 Table 3 Housing size A max. 11 11,05 13 14,00 15 16,92 17 20,09 19 22,78 21 25,96 23 29,13 25 32,31 6.4.2 Contact arrangements The contact arrangements in the inserts are specified by Figures 8 to 14. The fol