1、ANSI/ASHRAE Standard 93-2010 (RA 2014)(Reaffirmation of ANSI/ASHRAE Standard 93-2010)Methods of Testingto Determinethe Thermal Performanceof Solar CollectorsApproved by the ASHRAE Standards Committee on January 18, 2014; by the ASHRAE Board of Directors on January 22, 2014;and by the American Nation
2、al Standards Institute on January 23, 2014. ASHRAE Standards are scheduled to be updated on a five-year cycle; the date following the standard number is the year ofASHRAE Board of Directors approval. The latest edition of an ASHRAE Standard may be purchased on the ASHRAE website(www.ashrae.org) or f
3、rom ASHRAE Customer Service, 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. E-mail:ordersashrae.org. Fax: 678-539-2129. Telephone: 404-636-8400 (worldwide) or toll free 1-800-527-4723 (for orders in US andCanada). For reprint permission, go to www.ashrae.org/permissions. 2014 ASHRAE ISSN 1041-2336S
4、PECIAL NOTEThis American National Standard (ANS) is a national voluntary consensus standard developed under the auspices of ASHRAE.Consensus is defined by the American National Standards Institute (ANSI), of which ASHRAE is a member and which has approved thisstandard as an ANS, as “substantial agre
5、ement reached by directly and materially affected interest categories. This signifies the concurrenceof more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that aneffort be made toward their resolution.” Compliance with this
6、 standard is voluntary until and unless a legal jurisdiction makes compliancemandatory through legislation.ASHRAE obtains consensus through participation of its national and international members, associated societies, and public review.ASHRAE Standards are prepared by a Project Committee appointed
7、specifically for the purpose of writing the Standard. The ProjectCommittee Chair and Vice-Chair must be members of ASHRAE; while other committee members may or may not be ASHRAE members, allmust be technically qualified in the subject area of the Standard. Every effort is made to balance the concern
8、ed interests on all ProjectCommittees.The Manager of Standards of ASHRAE should be contacted for:a. interpretation of the contents of this Standard,b. participation in the next review of the Standard,c. offering constructive criticism for improving the Standard, ord. permission to reprint portions o
9、f the Standard.DISCLAIMERASHRAE uses its best efforts to promulgate Standards and Guidelines for the benefit of the public in light of available information andaccepted industry practices. However, ASHRAE does not guarantee, certify, or assure the safety or performance of any products, components,or
10、 systems tested, installed, or operated in accordance with ASHRAEs Standards or Guidelines or that any tests conducted under itsStandards or Guidelines will be nonhazardous or free from risk.ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDSASHRAE Standards and Guidelines are established to assist in
11、dustry and the public by offering a uniform method of testing for ratingpurposes,bysuggestingsafepracticesindesigningandinstallingequipment,byprovidingproperdefinitionsofthisequipment,andbyprovidingother information that may serve to guide the industry.The creation of ASHRAE Standards and Guidelines
12、 is determined by the need for them,and conformance to them is completely voluntary.In referring to this Standard or Guideline and in marking of equipment and in advertising, no claim shall be made, either stated or implied,that the product has been approved by ASHRAE.ASHRAE Standard Project Committ
13、ee 93CognizantTC:TC 6.7, Solar Energy UtilizationSPLS Liaison: Nadar R. Jayaraman*Denotes members of voting status when the document was approved for publicationCharles J. Cromer, Chair* James C. HugginsConstantinos A. Balaras* Sanford A. Klein*Mark Hertel* Marija S. Todorovic*ASHRAE STANDARDS COMMI
14、TTEE 20132014William F. Walter, Chair David R. Conover Malcolm D. KnightRichard L. Hall, Vice-Chair John F. Dunlap Rick A. LarsonKarim Amrane James W. Earley, Jr. Mark P. ModeraJoseph R. Anderson Steven J. Emmerich Cyrus H. NasseriJames Dale Aswegan Julie M. Ferguson Janice C. PetersonCharles S. Bar
15、naby Krishnan Gowri Heather L. PlattSteven F. Bruning Cecily M. Grzywacz Douglas T. ReindlJohn A. Clark Rita M. Harrold Julia A. Keen, BOD ExOWaller S. Clements Adam W. Hinge Thomas E. Werkema, Jr., CODebra H. KennoyStephanie C. Reiniche, Manager of Standards ASHRAE (www.ashrae.org). For personal us
16、e only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.CONTENTSANSI/ASHRAE Standard 93-2010 (RA 2014),Methods ofTesting to Determine theThermal Performance of Solar CollectorsSECTION PAGEForeword.21 Pur
17、pose 22 Scope23 Definitions and Nomenclature.24 Classifications.55 Requirements56 Instrumentation.67 Apparatus and Methods of Testing78 Test Procedures and Computations129 Data to be Recorded and Test Report 1910 References19Informative Appendix ABibliography24Informative Appendix BApparent Solar Ti
18、me and Local Time at Test Site .24Informative Appendix CProcedure to Evaluate and to Correct for Header Heat Losses.25Informative Appendix DMethod for Calculating Spectrum-WeightedValues of the Transmittance-Absorptance Product26Informative Appendix ECalculating Total Daily Energy Output for the Col
19、lector.26Informative Appendix FBiaxial Incident Angle Modifiers .40Informative Appendix GAcceptance Angle Determination for Single-Axis Linear Concentrating Collector.40Informative Appendix HIncident Angle Modifier 41Informative Appendix IProcedure for Testing Solar Collectors in Which the Heat Tran
20、sfer Fluid CanChange Phase in the Absorber and the Collected Energy is Removed Via anIntegral Condenser Heat Exchanger42NOTEApproved addenda, errata, or interpretations for this standard can be downloaded free of charge from the ASHRAEWeb site at www.ashrae.org/technology. 2014 ASHRAE1791 Tullie Cir
21、cle NE Atlanta, GA 30329 www.ashrae.org All rights reserved.ASHRAE is a registered trademark of the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.ANSI is a registered trademark of the American National Standards Institute. ASHRAE (www.ashrae.org). For personal use on
22、ly. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.2 ANSI/ASHRAE Standard 93-2010 (RA 2014)(This foreword is not part of this standard. It is merelyinformative and does not contain requirements necessar
23、yfor conformance to the standard. It has not been pro-cessed according to the ANSI requirements for a stan-dard and may contain material that has not been subjectto public review or a consensus process. Unresolvedobjectors on informative material are not offered theright to appeal at ASHRAE or ANSI.
24、)FOREWORDASHRAE Standard 93 provides a test procedure wherebysolar energy collectors can be tested both indoors and out-doors to rate the collectors in accordance with their thermalperformance and to determine their time constants and thevariations in their efficiency with changes in the angle of in
25、ci-dence between the suns direct rays and the normal to the col-lector aperture. The standard carefully defines its applicabilityto both liquid-cooled nonconcentrating and concentrating col-lectors and collectors that use air as the heat transfer fluid.First published in 1986, the Standard 93 was re
26、affirmedin 1991 and again in 2003. This revision of the standardbrings it into agreement with ISO Standard 9806-1. The testprocedure for performance remains the same as in previouseditions, but additional methods for calculating performanceefficiency from the recorded data have been added. Whereaspe
27、rformance was previously calculated based on gross areaand inlet fluid temperature, in this edition of the standardthree new methods of calculation are provided. Now perfor-mance can be calculated based upon (1) gross area and aver-age fluid temperature, (2) absorber area and inlet fluidtemperature,
28、 and (3) absorber area and average fluid temper-ature. In addition, the way in which the heat-capacity timeconstant is determined has also been changed to align in withISO 9806-1. In earlier editions this constant was determinedby exposing the collector to thermal stabilization, then cover-ing it. T
29、he heat capacity was found as function of how quicklythe collector cooled. In this edition, however, the collector iscovered to achieve thermal stabilization and then it is uncov-ered under exposure. The heat capacity is found as a functionof how quickly the collector heats up. Finally, various edit
30、o-rial corrections have been made, and the standards refer-ences have been updated to the most recent editions.This is a reaffirmation of Standard 93-2010. This stan-dard was prepared under the auspices of ASHRAE. It may beused, in whole or in part, by an association or governmentagency with due cre
31、dit to ASHRAE. Adherence is strictly on avoluntary basis and merely in the interests of obtaining uni-form guidelines throughout the industry.This version of thereaffirmation has no changes.1. PURPOSEThepurposeofthisstandardistoprovidetestmethodsfordetermining the thermal performance of solar energy
32、 collec-tors that use single-phase fluids and have no significant inter-nal energy storage.2. SCOPE2.1 This standard applies to nonconcentrating and concen-trating solar collectors in which a fluid enters the collectorthrough a single inlet and leaves the collector through a singleoutlet.2.1.1 Colle
33、ctors containing more than one inlet and morethan one outlet may be tested according to this standard pro-vided that the external piping or ducting can be connected soas to provide effectively a single inlet and a single outlet.2.2 The heat transfer fluid may be either a liquid or a gas butnot a mix
34、ture of the two phases.2.3 This standard contains methods for conducting testsoutdoors under natural solar irradiance and for conductingtests indoors under simulated solar irradiance.2.4 This standard provides test methods and calculationprocedures for determining steady-state and quasi-steady-state
35、 thermal performance, time, and angular response char-acteristics of solar collectors.2.5 This standard is not applicable to those collectors inwhich the thermal storage unit is an integral part of the col-lector to such an extent that the collection process and thestorage process cannot be separate
36、d for the purpose of makingmeasurements of these two processes.2.6 This standard does not apply to:(a) those unglazed solar collectors that can be tested inaccordance with ASHRAE Standard 96-1980 (RA89)1and(b) those collectors in which the heat transfer fluidchanges phase and the leaving transfer fl
37、uid containsvapor. However, a suggested test procedure is givenin Appendix I for those phase-change collectorswith an integral heat exchanger that conform to thedescriptions in Sections 2.1 and 2.2 of this standard.3. DEFINITIONS AND NOMENCLATURE3.1 Definitionsabsorber: the absorber is that part of
38、the solar collector thatreceives the incident radiation energy and transforms it intothermalenergy.Itmaypossessasurfacethroughwhichenergyis transmitted to the transfer fluid; however, the transfer fluiditself can be the absorber.absorber area: the absorber area is the total heat transfer areafrom wh
39、ich the absorbed solar irradiance heats the transferfluid or the area of the absorber medium if both transfer fluidand solid surfaces jointly perform the absorbing function.air mass: the air mass is the ratio of the mass of atmospherein the actual earth-sun path to the mass that would exist at seale
40、vel if the sun were directly overhead.angle, acceptance: the angular zone within which radiation isaccepted by the receiver of a concentrator. Radiation is said tobe accepted because radiation incident within this anglereaches the absorber after passing through the aperture. ASHRAE (www.ashrae.org).
41、 For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.ANSI/ASHRAE Standard 93-2010 (RA 2014) 3angle of incidence: the angle of incidence is the anglebetween the direct solar irradiance
42、and the normal to the aper-ture plane.apparent solar time: time based on the apparent angularmotion of the sun across the sky, with solar noon the time thesun crosses the meridian of the observer.area, aperture: the aperture area is the maximum projectedarea of a solar collector through which the un
43、concentratedsolar radiant energy is admitted.area, gross: thegrosscollectorareaisthemaximumprojectedarea of the complete collector module including integralmounting means. (Note: The “complete collector module” isthe collector unit shipped by the manufacturer for installationon a structure or in an
44、array. However, if the manufacturerrequires that additional insulation be placed in any manneralong all or any part of the perimeter (edge) of the collectormodule in order that the performance characteristics, deter-mined with the test procedures herein, will be indicative ofthosethatwouldoccurwhent
45、hecollectorispartofaninstalledsystem, the gross area will have to be adjusted. If the installedarray is specified as a one-row array, then the dimensions arethe centerline-to-centerline distance between two adjacentcollectors installed in the array times the collector height. Ifthe installed array i
46、s specified as a two-row or larger array, thegross area is determined by the horizontal and longitudinalcenterline-to-centerline distances of four adjacent collectorsinstalled in the array.)collector, concentrating: a concentrating collector is a solarcollector that uses reflectors, lenses, or other
47、 optical elementsto concentrate the radiant energy passing through an apertureonto an absorber of which the surface area is smaller than theaperture area.collector, flat-plate: a flat-plate collector is a noncon-centrating solar collector in which the absorbing surface isessentially planar.collector
48、, nonconcentrating: a nonconcentrating collector isa solar collector in which the absorber heat flux is not greaterthan the solar irradiance across the aperture area. It may ormaynotcontainopticalelementstodirecttheradiantfluxontothe absorber.concentration ratio: for purposes of this test standard,
49、theconcentration ratio of a concentrating solar collector is theratio of the aperture area to the absorber area.cover, collector: the collector cover glazing is the materialcovering the aperture to provide thermal and environmentalprotection.efficiency, instantaneous thermal: the instantaneous thermalefficiencyofasolarcollectoristheamountofenergyremovedby the transfer fluid per unit of gross collector area during thespecifiedtimeperioddividedbytheglobaltotalsolarradiationincident on the collector per unit area during the same testperiod, under steady state o