1、Designation: C 1007 08Standard Specification forInstallation of Load Bearing (Transverse and Axial) SteelStuds and Related Accessories1This standard is issued under the fixed designation C 1007; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the installation and erectionrequirements for load bearing (transve
3、rse and axial) steel studsand related accessories 0.0329 in. (0.836 mm) to 0.1120 in.(2.845 mm) thick.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not con
4、sidered standard.1.3 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.2. Referenced Documents2.1 ASTM Standards:2C11 Terminology Relating
5、 to Gypsum and Related Build-ing Materials and SystemsC 841 Specification for Installation of Interior Lathing andFurringC 954 Specification for Steel Drill Screws for the Applica-tion of Gypsum Panel Products or Metal Plaster Bases toSteel Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84mm) in Thi
6、cknessC 955 Specification for Load-Bearing (Transverse andAxial) Steel Studs, Runners (Tracks), and Bracing orBridging for Screw Application of Gypsum Panel Productsand Metal Plaster BasesC 1063 Specification for Installation of Lathing and Furringto Receive Interior and Exterior Portland Cement-Bas
7、edPlaster2.2 American Iron and Steel Institute Publication (AISI):Cold-Formed Steel Design Manual: Specifications for theDesign of Cold-Formed Steel Structural Members,1986 Revision and 1989 addendum32.3 American Welding Society Documents (AWS):D1.3 Specification for Welding Sheet Steel in Structure
8、s42.4 Military Specification:MIL-P-21035 Paint, High Zinc Dust Content, GalvanizingRepair52.5 Federal Specification:FF-P-395 Pin, Drive, Guided and Pin Drive, Power Actu-ated Fasteners for Power Actuated and Hand ActuatedFastening Tools53. Terminology3.1 Definitions shall be in accordance with Termi
9、nologyC11.3.2 Definitions of Terms Specific to This Standard:3.2.1 axial loads, nthose loads applied to a member in thesame plane as its major centroidal axis.3.2.2 cripple studs, nless than full height studs above aheader or below a sill.3.2.3 framing members, nstuds joist, runners (tracks),bridgin
10、g and bracing and related accessories.3.2.4 header, nthe stud assembly or the track assembly, orboth, placed at a right angle to supporting studs that creates thetop of a framed opening.3.2.5 jack stud, na framing member which providessupport at the end of a header.3.2.6 panelized construction, nfab
11、rication of framingmembers into an assembly prior to erection.3.2.7 sill, nthe stud assembly or the track assembly, orboth, placed at a right angle to supporting studs that creates thebottom of a framed opening.1This specification is under the jurisdiction of ASTM Committee C11 onGypsum and Related
12、Building Materials and Systems and is the direct responsibilityof Subcommittee C11.03 on Specifications for theApplication of Gypsum and OtherProducts in Assemblies.Current edition approved Sept. 1, 2008. Published September 2008. Originallyapproved in 1983. Last previous edition approved in 2004 as
13、 C 1007 04.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Iron and Steel Institute
14、(AISI), 1140 ConnecticutAve., NW, Suite 705, Washington, DC 20036, http:/www.steel.org.4Available from American Welding Society (AWS), 550 NW LeJeune Rd.,Miami, FL 33126, http:/www.aws.org.5Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 1911
15、1-5094, Attn: NPODS.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.8 transverse loads, nthose loads applied to a memberin a plane perpendicular to its major centr
16、oidal axis.4. Storage of Materials4.1 Products shall be protected from adverse weather andjob site conditions that will cause any physical damage.4.2 Materials shall be stored on a flat plane.4.3 Any damaged materials shall be removed from the jobsite immediately.5. Materials5.1 Framing membersSpeci
17、fication C 955.5.2 Zinc-rich paintMIL-P-21035.5.3 Steel drill screwsSpecification C 954. Screws shallhave rust inhibitive coating suitable for the intended installa-tion.5.4 Power actuated drive pinsFF-P-395.6. Fastenings and Attachments6.1 Anchorage of the tracks to the structure shall be withmetho
18、ds designed for the specific application of sheet steel tothat surface. Size, penetration, type, and spacing shall bedetermined by design.6.2 Welds shall conform to the requirements of AWS D1.3,and AISI Manual, section E 2. Welds shall be butt, fillet, spot,or groove type, the appropriateness of whi
19、ch shall be deter-mined by, and within, the design calculations. All welds shallbe touched-up using zinc rich paint for galvanized members,and paint similar to that used by the manufacturer for paintedmembers.6.3 Steel drill screws shall be of the minimum diameterindicated by the design of that part
20、icular attachment detail.Penetration through joined materials shall not be less than threeexposed threads.6.4 Wire tying in structural applications shall not be permit-ted.7. Tolerances7.1 Vertical alignment (plumbness) of studs shall be within1/960 (18 in. in 10 ft 0 in.) of the span.7.2 Horizontal
21、 alignment (levelness) of walls shall be within1/960 (18 in. in 10 ft 0 in.) of their respective lengths.7.3 Spacing of the framing members shall not be more than618 in. (3 mm) from the designed spacing, provided that thecumulative error does not exceed the requirements of thefinishing materials.7.4
22、 Squareness of the prefabricated panels shall be not morethan18 in. (3 mm) out of square within the length of that panel.INSTALLATION8. General Installation8.1 Methods of construction shall be either stickbuilt orpanelized.8.2 Stud to track connections shall be designed to meet orexceed the design l
23、oads required.8.3 Allowance for vertical deflection of the structure shallbe as required by the designer.8.4 Transversely loaded studs shall not be required to sitsquarely in tracks, but shall be attached to the tracks.8.5 Axially loaded studs shall be fabricated with the studsseated squarely within
24、18 in. (3 mm) of the web portion of thetop and bottom tracks and shall be attached to the tracks.8.6 All axially loaded members shall be aligned vertically toallow for full transfer of the loads down to the foundation.Vertical alignment shall be maintained at floor/wall intersec-tions.8.7 Bearing sh
25、all be provided under tracks to provide forload transfer in axially loaded assembles.8.8 Additional corrosion protection shall not be required onedges of metallic coated steel framing members, shop or fieldcut, punched or drilled.8.9 Cutting and Splicing of Members:8.9.1 Cutting of steel framing mem
26、bers shall be accom-plished with a saw or shear.8.9.2 Torch cutting of framing members shall not be per-mitted.8.9.3 Splicing of axially loaded framing members shall notbe permitted.8.9.4 Cutting of flanges in stud and joist framing membersshall not be permitted.8.9.5 Cutting of additional holes oth
27、er than those providedby the manufacturer in framing members shall not be permit-ted.8.10 Temporary bracing shall be provided and left in placeuntil the work is permanently stabilized.8.11 Bridging shall be of the size and type shown on theshop drawings and as called for in the design calculations.
28、Forfurther description of the shop drawings see Annex A3.8.12 Header and Jack Stud Installation:8.12.1 Headers shall be installed in all openings in axiallyloaded walls that are larger than the stud spacing in that wall.8.12.1.1 Headers shall be installed so that they lie whollywithin the width of t
29、he stud wall.8.12.1.2 Insulation (equal to the job requirements) shall beplaced in all jamb and header type conditions that will be inaccessible after their installation into the wall.8.12.2 Jack studs shall be securely connected to the headerand must seat squarely in the lower track of the wall ina
30、ccordance with 8.4.8.12.3 If the header is designed to be installed immediatelyabove the wall opening the cripple studs that occur over theheader shall be designed to carry all superimposed loads.8.13 Wall track (runners) shall not be used to support anyload unless specifically designed for that pur
31、pose.9. Panelized Construction9.1 Panels shall be designed to resist all construction andhandling loads as well as live loads.9.2 Handling and lifting of prefabricated panels shall notcause permanent distortion in any member or collateral mate-rial.9.3 All stud-to-track connections shall be installe
32、d prior tohoisting the panel.C10070829.4 Where splicing of the track is necessary between studspacings, a piece of stud not less than 12 in. (305 mm) longshall be placed in the track fastened with not less than twoscrews per flange to each piece of track or welds shall beprovided as required.NOTE 1C
33、laddings may be permitted to be attached prior to panelinstallation.9.5 Attachment of the panel to the structure shall be asshown on the design drawings.9.6 All panels shall be aligned to provide continuity of anywall/floor surface.10. Stick Built (Non-Panelized) Members10.1 Tracks shall be aligned
34、accurately at supporting struc-ture and shall be fastened to the structure.10.2 Track intersections shall butt evenly.10.3 Doors, windows, and other items installed in the wallshall be securely anchored to the wall by means of clips,angles, screws, bolts, etc.11. Keywords11.1 axial; loadbearing; run
35、ners; steel; studs; tracks;transverseANNEXES(Mandatory Information)A1. DESIGN REQUIREMENTSA1.1 Physical properties and allowable load capabilities ofmaterials shall be developed in accordance with AISI DesignManual, as provided by Specification C 955.A1.2 Studs shall be spaced to suit the design req
36、uirementsand limitations of collateral materials.A1.3 All applicable loads, strains, deflections, shear andweb crippling, and bending of all sections shall be examined.A1.4 All connections (member-to-member and member-to-structure) shall be examined taking into account all relevantphysical strengths
37、 and properties.A1.5 Selected walls shall be designed to provide framestability and lateral load resistance. Diagonal steel strapping orother engineered methods shall be used to provide framestability and lateral load resistance. Diagonal steel strappingshall be used to transfer lateral loads to the
38、 structure andfoundation. Additional studs shall be provided to resist thevertical component of the loads from the diagonal bracing.A1.6 Wall bridging shall be designed to provide resistanceto minor axis bending and rotation of wall studs.A2. INSTALLATION REQUIREMENTSA2.1 Gypsum board shall be attac
39、hed to the steel studs inaccordance with the appropriate specification.A2.2 Metal plaster bases shall be attached in accordancewith Specification C 841 or Specification C 1063, except screwheads shall be of a size and type suitable for positive (nomovement) attachment.A2.3 When diaphragm rated compo
40、nents are substituted forbridging, they shall be installed prior to loading of the wall. Ifcomponents are installed on one side of the wall only, then theother stud flanges shall be bridged with suitable bridging.Bridging is not required to be removed when diaphragm ratedcomponents are installed.A2.
41、4 Care shall be taken to allow for additional studs atpanel intersections, corners, doors, window, control joints, etc.A2.5 Provision for structure movement shall be provided asindicated and necessary by design or code requirements.A2.6 Properly designed splices, cutting of flanges, andholes other t
42、han those provided by the manufacturer shall beapproved in writing by the engineer of record.A2.7 Care shall be taken to properly distribute constructionmaterials so that they do not exceed the project design loads.C1007083A3. SUBMITTALSA3.1 The following items shall be considered for approvalprior
43、to delivery of materials to the site:A3.1.1 Shop DrawingsDrawings shall illustrate materi-als; shop coatings; steel thickness; details of fabrication; detailsof attachment to adjoining work; size, location, spacing offasteners for attaching framing to itself; details of attachment tothe structure; a
44、ccessories and their installation; and criticalinstallation procedures. Drawings shall include plans, eleva-tions, sections and details.A3.1.2 SamplesSamples shall be representative pieces ofall framing component parts and accessories.A3.1.3 CertificationCertification shall be a statementfrom the ma
45、nufacturer certifying that the materials conform tothe appropriate requirements as outlined in the contract docu-ments.A3.1.4 CalculationsEngineering calculations shall beprepared verifying the assemblys ability to meet or exceeddesign requirements as required by local codes and authorities.A3.1.5 D
46、escriptive LiteratureManufacturers literatureshall contain product and installation specifications and details.SUMMARY OF CHANGESCommittee C11 has identified the location of selected changes to this specification since the last issue,C 1007 04, that may impact the use of this specification. (Approve
47、d September 1, 2008)(1) Revised 8.8.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the ris
48、kof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of thi
49、s standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copi