1、Designation:C50611 Designation: C506 12Standard Specification forReinforced Concrete Arch Culvert, Storm Drain, and SewerPipe1This standard is issued under the fixed designation C506; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification cover
3、s reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes,storm water, and for the construction of culverts.1.2 This specification is the inch-pound companion to C506M; therefore, no SI equivalents are presented in the specification.NOTE 1This specification is
4、 a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or therelationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of thisproduct depends upon the proper sel
5、ection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the constructionspecifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipespecified and provide insp
6、ection at the construction site.2. Referenced Documents2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelA82/A82MSpecification for Steel Wire, Plain, for Concrete ReinforcementA185/A185MSpecification for Steel Welded Wire Reinforcement, Plain, for ConcreteA496/A496MSpecification
7、for Steel Wire, Deformed, for Concrete ReinforcementA497/A497MSpecification for Steel Welded Wire Reinforcement, Deformed, for ConcreteA615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete ReinforcementA706/A706M Specification for Low-Alloy Steel Deformed and Plain Bars for
8、Concrete ReinforcementA1064/A1064M Specification for Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for ConcreteC33 Specification for Concrete AggregatesC150 Specification for Portland CementC260 Specification for Air-Entraining Admixtures for ConcreteC309 Specification for Liquid Mem
9、brane-Forming Compounds for Curing ConcreteC494/C494M Specification for Chemical Admixtures for ConcreteC497 Test Methods for Concrete Pipe, Manhole Sections, or TileC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Co
10、ncreteC822 Terminology Relating to Concrete Pipe and Related ProductsC989 Specification for Slag Cement for Use in Concrete and MortarsC1017/C1017M Specification for Chemical Admixtures for Use in Producing Flowing ConcreteC1116 Specification for Fiber-Reinforced Concrete and Shotcrete3. Terminology
11、3.1 DefinitionsFor definitions of terms relating to concrete pipe, see Terminology C822.4. Classification4.1 Pipe manufactured according to this specification shall be of three classes identified as Class A-II, A-III, and A-IV. The1This specification is under the jurisdiction of ASTM Committee C13 o
12、n Concrete Pipe and is the direct responsibility of Subcommittee C13.02 on Reinforced Sewerand Culvert Pipe.Current edition approved Feb.May 1, 2011.2012. Published March 2011.June 2012. Originally approved in 1963. Last previous edition approved in 20102011 asC50610b.C506 11. DOI: 10.1520/C0506-112
13、.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.1This document is not an ASTM standard and is intended onl
14、y to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versi
15、onof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.strength requirements are prescribed in Table 1.5. Basis of Acceptance5.1 Unless otherwise designated by
16、the owner at the time of, or before placing an order, there are two separate and alternativebases of acceptance. Independent of the method of acceptance, the pipe shall be designed to meet both the 0.01-in. crack andultimate strength requirements.5.1.1 Acceptance on Basis of Plant Load Bearing Tests
17、, Material Tests, and Inspection of Manufactured Pipe for Visual Defectsand ImperfectionsAcceptability of the pipe in all diameters and classes produced in accordance with 7.1 or 7.2, shall bedetermined by the results of the three-edge-bearing tests as defined in 11.3.1; by such material tests as ar
18、e required in accordancewith 6.2, 6.3, 6.5, and 6.6, by an absorption test of the concrete from the wall of the pipe as required in 11.9; and by visualinspection of the finished pipe to determine its conformance with the accepted design and its freedom from defects.5.1.2 Acceptance on Basis of Mater
19、ial Tests and Inspection of Manufactured Pipe for Defects and ImperfectionsAcceptabilityof the pipe in all diameters and classes produced in accordance with 7.1 or 7.2 shall be determined by the results of such materialtests as are required in 6.2, 6.3, 6.5, and 6.6; by crushing tests on concrete co
20、res or cured concrete cylinders; by an absorption testof the concrete from the wall of the pipe for each mix design that is used on an order; and by inspection of the finished pipe,including amount and placement of reinforcement, to determine its conformance with the accepted design and its freedom
21、fromdefects.5.1.3 When agreed upon by the owner and the manufacturer, any portion or any combination of the tests itemized in 5.1.1 or5.1.2 may form the basis of acceptance.TABLE 1 Strength Requirements for Reinforced Concrete PipeAApprox-imateEquivalentRoundSize, in.T,in.Mini-mumRise,in.Mini-mumSpa
22、n,in.f 8c,BMPADouble Line ReinforcementCSingle LineReinforcementContinuous BasicReinforcement = AsDAdditional Reinforcement = AsDClass Inner Cage Outer Cage“U”(Inner Cage)“V”(Outer Cage)A-II A-III A-IV A-II A-III A-IV A-II A-III A-IVDimen-sion,in.A-II A-III A-IVDimen-sion,in.A-II A-III A-IV A-II A-I
23、II A-IV15 214 11 18 4 4 4 . . . . . . . . . . . . . . 0.08 0.12 0.1718 212 1312 22 4 4 4 . . . . . . . . . . . . . . 0.11 0.14 0.2621 238 1512 26 4 4 4 . . . . . . . . . . . . . . 0.12 0.17 0.2924 3 18 2812 4 4 4 . . . . . . . . . . . . . . 0.16 0.21 0.3230 312 2212 3614 4 4 4 0.09 0.12 0.18 0.07 0.
24、09 0.14 26 0.09 0.12 0.18 29 0.07 0.09 0.12 0.18 0.24 0.3636 4 2658 4338 4 4 4 0.11 0.15 0.21 0.09 0.12 0.17 30 0.11 0.15 0.21 34 0.09 0.12 0.16 0.21 0.30 0.4442 412 31516 5118 4 4 4 0.12 0.18 0.27 0.10 0.14 0.21 34 0.12 0.18 0.27 39 0.10 0.14 0.21 0.26 0.36 0.5448 5 36 5812 4 4 . 0.15 0.21 . 0.12 0
25、.17 . 42 0.15 0.21 . 43 0.12 0.17 . 0.30 0.44 .54 512 40 65 4 4 . 0.18 0.24 . 0.14 0.19 . 48 0.18 0.24 . 49 0.14 0.19 . 0.36 0.48 .60 6 45 73 4 4 . 0.21 0.27 . 0.17 0.21 . 52 0.21 0.27 . 55 0.17 0.21 . 0.42 0.56 .72 7 54 88 4 5 . 0.26 0.36 . 0.20 0.27 . 60 0.26 0.36 . 67 0.20 0.27 . 0.52 0.72 .84 8
26、62 102 4 5 . 0.32 0.44 . 0.24 0.34 . 68 0.32 0.44 . 77 0.24 0.34 . 0.64 0.88 .90 812 72 115 . . . . . . . . . . . . . . . . . . . .96 9 7712 122 . . . . . . . . . . . . . . . . . . . .108 10 8718 138 . . . . . . . . . . . . . . . . . . . .120 11 9678 154 . . . . . . . . . . . . . . . . . . . .132 10
27、 10612 16834 . . . . . . . . . . . . . . . . . . . .D-Loads for 3-Edge-Bearing MethodClass 0.01-in.CrackUltimateII 1000 1500III 1350 2000IV 2000 3000NoteTest load in pounds per linear footequals D-load 3 inside span in feet.AFor modified or special designs, see 7.3.Bf 8c, ksi = minimum compressive s
28、trength of concrete in thousands of pounds-force per square inch.CAs an alternative to designs requiring double line reinforcement, the reinforcement may be positioned and proportioned so that the total reinforcement of the inner cageplus the middle cage shall not be less than that specified for the
29、 inner cage continuous basic reinforcement, and the additional reinforcement “U ” and the totalreinforcement of the outer cage plus the middle cage shall not be less than that specified for the outer cage continuous basic reinforcement and the additional reinforcement“V.”DAs= circumferential steel a
30、rea in square inches per longitudinal foot of pipe barrel in each continuous basic cage and additional cages in area denoted “U ” and “V.”Dimensions “U ” and “V ” are measured on the center line of the culvert wall.C506 1225.2 Age for AcceptancePipe shall be considered ready for acceptance when they
31、 conform to the requirements as indicated bythe specified tests.6. Materials6.1 The aggregate shall be so sized, graded, proportioned, and mixed with such proportions of portland cement, blendedhydraulic cement, or portland cement and supplementary cementing materials, or admixtures, or a combinatio
32、n thereof, if used,and water to produce a homogeneous concrete mixture of such quality that the pipe will conform to the test and designrequirements of this specification. In no case, however, shall the proportion of portland cement, blended hydraulic cement, or acombination of portland cement and s
33、upplementary cementing materials be less than 470 lb/yd3.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirements of Specification C150, or shall be portland blast-furnace slag cement,or slag modified portland cement, or portland-pozzolan cement conforming to the requirements
34、of Specification C595, except thatthe pozzolan constituent in the Type IP portland-pozzolan cement shall be fly ash.6.2.2 Ground Granulated Blast-Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120 ofSpecification C989.6.2.3 Fly AshFly ash shall conform to the requirement
35、s of Class F or Class C of Specification C618.6.2.4 Allowable Combinations of Cementitious MaterialsThe combination of cementitious materials used in the concrete shallbe one of the following:6.2.4.1 Portland cement only,6.2.4.2 Portland blast furnace slag cement only,6.2.4.3 Slag modified portland
36、cement only,6.2.4.4 Portland pozzolan cement only,6.2.4.5 A combination of portland cement and ground granulated blast-furnace slag,6.2.4.6 A combination of portland cement and fly ash,6.2.4.7 A combination of portland cement, ground granulated blast-furnace slag (not to exceed 25 % of the total cem
37、entitiousweight) and fly ash (not to exceed 25 % of the total cementitious weight, or6.2.4.8 A combination of portland pozzolan cement and fly ash, provided the fly ash added does not exceed 25 % by weight ofthe portland pozzolan cement.6.3 AggregatesAggregates shall conform to Specification C33 exc
38、ept that the requirement for gradation shall not apply.6.4 Admixtures and BlendsThe following admixtures and blends are allowable:6.4.1 Air-entraining admixture conforming to Specification C260;6.4.2 Chemical admixture conforming to Specification C494/C494M;6.4.3 Chemical admixture for use in produc
39、ing flowing concrete conforming to Specification C1017/C1017M; and6.4.4 Chemical admixture or blend approved by the owner.6.5 Steel ReinforcementReinforcement shall consist of wire conforming to Specification A82/A82M or SpecificationA496/A496M; or of wire reinforcement conforming to SpecificationA1
40、85/A185M or SpecificationA497/A497MReinforcementshall consist of wire conforming to SpecificationA1064/A1064M; or of bars conforming to SpecificationA36/A36M, SpecificationA615/A615M Grade 40 or 60, or Specification A706/A706M Grade 60.6.6 Synthetic FibersCollated fibrillated virgin polypropylene fi
41、bers may be used, at the manufacturers option, in concretepipe as a nonstructural manufacturing material. Only Type III synthetic fibers designed and manufactured specifically for use inconcrete and conforming to the requirements of Specification C1116 shall be accepted.7. Design7.1 Size and Dimensi
42、onsThe standard sizes of arch pipe are listed in Table 1. The internal dimensions for each standard sizeshall be as defined in Fig. 1, subject to the permissible variations of Section 12.7.2 Design TablesThe wall thickness, compressive strength of concrete, and the area of circumferential reinforcem
43、ent shallbe as prescribed in Table 1, subject to the provisions of 7.3 and Sections 11 and 12.7.2.1 Footnotes to the tables herein are intended to be amplifications of the tabulated requirements and are to be consideredapplicable and binding as if they were contained in the body of the specification
44、.7.3 Modified and Special Designs:7.3.1 If permitted by the owner, the manufacturer may request approval by the owner of modified designs that differ from thedesigns in this Section 7 or special designs for sizes and loads beyond those shown in Table 1, or special designs for pipe sizesthat do not h
45、ave steel reinforcement areas shown in Table 1.7.3.2 Such modified or special designs shall be based on rational or empirical evaluations of the ultimate strength and crackingbehavior of pipe and shall fully describe to the owner any deviations from the requirements of this Section 7. The descriptio
46、ns ofmodified or special designs shall include the wall thickness, the concrete strength, and the area, type, placement, number of layers,and strength of the steel reinforcement.7.3.3 The manufacturer shall submit to the owner proof of the adequacy of the proposed modified or special design. Such pr
47、oofmay comprise the submission of certified three-edge-bearing tests already made, which are acceptable to the owner or, if suchC506 123three-edge-bearing tests are not available or acceptable, the manufacturer may be required to perform proof tests on sizes andclasses selected by the owner to demon
48、strate the adequacy of the proposed design.7.3.4 Such pipe must meet all of the test and performance requirements specified by the owner in accordance with Section 5.7.4 AreaIn this specification, when the word area is not described by adjectives, such as cross-section or single wire, it shallbe und
49、erstood to be the cross-sectional area of reinforcement per unit lengths of pipe.8. Reinforcement8.1 Circumferential Reinforcement A line of circumferential reinforcement for any given total area may be composed of twolayers for pipe with wall thicknesses of less than 7 in. or three layers for pipe with wall thicknesses of 7 in. or greater. The layersshall not be separated by more than the thickness of one longitudinal plus14 in. The multiple layers shall be fastened together toform a single cage. All other specification requirements su