1、Designation: C953 10Standard Test Method forTime of Setting of Grouts for Preplaced-Aggregate Concretein the Laboratory1This standard is issued under the fixed designation C953; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This method covers the determination test of time ofsetting of hydraulic cement grout mixtures used in preplac
3、ed-aggregate (PA) concrete using the vicat apparatus.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsi
4、bility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C125 Terminology Relating to Concrete and Concrete Ag-gregatesC191 Test Methods for Time of Set
5、ting of HydraulicCement by Vicat NeedleC219 Terminology Relating to Hydraulic CementC938 Practice for Proportioning Grout Mixtures forPreplaced-Aggregate ConcreteC511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and Concr
6、etes3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminologies C125 and C219.4. Summary of Method4.1 The time of setting, initial and final, of a sample of fluidgrout is determined using the Vicat apparatus.5. Significance and Use5.1 This test method
7、 determines the setting time of groutmixed to the fluid consistency required for its use in PAconcrete.5.2 The time of setting is also useful in determining theacceptability of components of grout that must be mixed to thefluid consistency required for production of PA concrete.6. Apparatus6.1 Vicat
8、 Apparatus, in accordance with Test Method C191.6.2 Moist Room, maintained in accordance with Specifica-tion C511.7. Test Sample7.1 The test sample shall consist of at least 300 mL of grouttaken from a freshly-mixed batch prepared in accordance withPractice C938 obtained from a mixer at the laborato
9、ry orconstruction site.8. Procedure8.1 Warm the Vicat conical ring and base plate to approxi-mately 100 C.8.2 Apply a thin film of paraffin wax to the base of theconical ring and place the waxed conical ring on the base plate.Place a weight on the conical ring to ensure intimate contactwith the base
10、 plate and allow the conical ring and plate to coolto room temperature.8.3 Fill the conical ring apparatus with grout flush with itstop within 2 min after completion of mixing. Strike off thegrout flush with the top of the conical ring by a single obliquestroke of a sharp-edged trowel held at a slig
11、ht angle to the topof the ring. Smooth the top, if necessary, with a few lighttouches of the pointed end of the trowel. Take care not tocompress the sample during these cutting and smoothingoperations. The time of completion of molding shall be takenas the start of measurement of time of set.8.4 Sto
12、re the specimen in the moist room.8.5 Determine the time of setting using the proceduredescribed in Test Method C191 except that the first readingshall be taken 3 h 6 15 min after pouring the specimen.NOTE 1Grouts used to evaluate grout fluidifier or for use in PAconcrete will normally reach initial
13、 set in about 4 h.1This test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.41 on Hydraulic Cement Grouts.Current edition approved June 15, 2010. Published July 2010. Originallyapproved in 1981. Last previ
14、ous edition approved in 2006 as C95306. DOI:10.1520/C0953-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.
15、1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.9. Report9.1 The report shall include the following:9.1.1 Identification of the grout sample,9.1.2 Time of initial sett
16、ing and final setting in hours andminutes,9.1.3 Temperature of group sample at the beginning of thetest, and9.1.4 Ambient temperature during the test.10. Precision and Bias10.1 PrecisionWhen data have been compiled that aresuitable for use in preparing a precision statement, suchstatement will be pr
17、epared.10.2 BiasNo statement on Bias can be prepared becausethere are no standard reference materials.11. Keywords11.1 grout; preplaced-aggregate concrete; time of settingSUMMARY OF CHANGESCommittee C09 has identified the location of selected changes to this test method since the last issue,C95306,
18、that may impact the use of this test method. (Approved June 15, 2010)(1) Added new Section 3 Terminology to reference appropriateterminology documents under C01 and C09 and renumberedsubsequent sections.ASTM International takes no position respecting the validity of any patent rights asserted in con
19、nection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the respon
20、sible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful
21、consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 1
22、00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).C953 102