1、Designation: D 2340 03Standard Test Method forPeroxides in Styrene Monomer1This standard is issued under the fixed designation D 2340; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthes
2、es indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope *1.1 This test method covers the determination of the perox-ide content of styrene monomer.1.2 In determining the conformance of the test results usingthis
3、method to applicable specifications, results shall berounded off in accordance with the rounding-off method ofPractice E 29.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appr
4、o-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 7.2. Referenced Documents2.1 ASTM Standards:D 1193 Specification for Reagent Water2D 3437 Practice for Sampling and Handling Liquid CyclicProducts3
5、E 29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Specifications42.2 Other Documents:OSHA Regulations, 29 CFR, paragraphs 1910.1000 and1910.120053. Summary of Test Method3.1 A specimen of styrene monomer is added to a solutionof isopropanol and acetic acid. A satur
6、ated solution of sodiumiodide in isopropanol is added and the solution refluxed. Theperoxides present liberate iodine from sodium iodide quantita-tively. The liberated iodine is then titrated with sodiumthiosulfate to a colorless end point.4. Significance and Use4.1 This test method is suitable for
7、determining the quantityof peroxides in styrene monomer both for quality control andquality assurance of the product.5. Apparatus5.1 Erlenmeyer Flasks, glass-stoppered, 500-mL, equippedwith 300-mm Liebig condensers having inner and outer stan-dard taper joints.5.2 Electric Hot Plate with totally enc
8、losed heating unit.5.3 Boiling Chips.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Societywhere such
9、 specifications are available.6Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean r
10、eagent water as definedby Type III of Specification D 1193.6.3 Glacial Acetic Acid.6.4 Isopropyl Alcohol.6.5 Sodium Iodide Isopropyl Alcohol SolutionPrepare asaturated solution of sodium iodide in isopropanol (approxi-mately 200 g NaI/L).6.6 Sodium Thiosulfate, Standard Solution (0.01 N)Dissolve 2.5
11、 g of sodium thiosulfate (Na2S2O35H2O) and 0.11This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.07 on Styrene, Ethylbenzene, and C9and C10AromaticHydrocarbons.Current edition approved Ja
12、n. 10, 2003. Published March 2003. Originallyapproved in 1965. Last previous edition approved in 1996 as D 2340 96.2Annual Book of ASTM Standards, Vol 11.01.3Annual Book of ASTM Standards, Vol 06.04.4Annual Book of ASTM Standards, Vol 14.02.5Available from U.S. Government Printing Office Superintend
13、ent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401.6Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for Labora
14、toryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West C
15、onshohocken, PA 19428-2959, United States.g of sodium carbonate (Na2CO3) in water and dilute to 1 L.Standardize against primary standard potassium dichromate(K2Cr2O7).7. Hazards7.1 Consult the latest OSHA regulations, suppliers MaterialSafety Data Sheets, and local regulations regarding all mate-ria
16、ls used in this test method.7.2 Styrene monomer is flammable and polymerizes exo-thermally on contact with peroxides, mineral acids, and alu-minum chloride.7.3 Isopropyl alcohol is flammable and should be kept awayfrom open flame and spark-producing apparatus. Use only ahot plate with totally enclos
17、ed heating unit in this analysis.8. Sampling8.1 Collect the sample as directed in Practice D 3437.9. Procedure9.1 Add 200 mL of isopropyl alcohol into each of two500-mL Erlenmeyer flasks containing several boiling chips.Add 10 mL of glacial acetic acid to each flask. Into one flaskpipet 50 mL of the
18、 styrene monomer sample. Identify this flaskas “Sample” and the other flask as“ Blank.” Fit the condenserin place (Warning: see 7.2 and 7.3). Heat the contents of theflasks to boiling and pipet 50 mL of the saturated NaI isopropylalcohol solution into each.9.2 Continue boiling gently for 10 min. At
19、the end of theboiling period, remove the flasks from the heat source. Rinseeach condenser with two 10-mL portions of water, adding therinsings to the respective flasks. Cool the flasks to roomtemperature. Titrate the liberated iodine in each flask with 0.01N Na2S2O3solution to a light yellow color a
20、nd continue totitrate slowly until the yellow color just disappears.10. Calculation10.1 Calculate the peroxide content of the specimens ashydrogen peroxide, in parts per million (mg/kg) as follows:Peroxides, mg/kg 5 A 2 B! 3 N 3 1.7 3 104# / 50 3 C!where:A = total millilitres of Na2S2O3solution requ
21、ired fortitration of the specimen,B = total millilitres of Na2S2O3solution required fortitration of the blank,N = normality of Na2S2O3solution used, andC = density of styrene monomer at temperature pipetted(an approximate density of 0.9 may be used todetermine the sample weight).11. Report11.1 Repor
22、t the peroxide content to the nearest 1 mg/kg.12. Precision and Bias12.1 Intermediate Precision (formerly calledRepeatability)Duplicate results by the same operator shouldnot be considered suspect (95 % confidence limit) unless theydiffer by more than the following:Peroxide Content,mg/kgRepeatabilit
23、y,mg/kg1to60 612.2 ReproducibilityThe averages of duplicate resultssubmitted by each of two laboratories should not be consideredsuspect (95 % confidence limit) unless they differ by more thanthe following:Peroxide Content,mg/kgReproducibility,mg/kg1to60 1312.3 BiasSince there is no accepted referen
24、ce materialsuitable for determining the bias in this test method formeasuring peroxides in styrene monomer, bias has not beendetermined.13. Keywords13.1 peroxide content; peroxide in styrene; styreneSUMMARY OF CHANGESCommittee D16 has identified the location of selected changes to this standard sinc
25、e the last issue(D 2340 - 96) that may impact the use of this standard.(1) This standard was editorially revised in 2003 to include aBias statement.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users
26、of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every fi
27、ve years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical
28、committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).D2340032
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1