1、Designation: D 3209 93 (Reapproved 2004)Standard Test Method forFreeze/Thaw Resistance of Polymer Floor Polishes1This standard is issued under the fixed designation D 3209; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the stabil-ity of polymer emulsion floor polishes when these are expos
3、edto repeated cycles of freezing and thawing. Possible degrada-tion of the emulsion is observed and possible reduction ofinitial gloss is measured.1.2 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this sta
4、ndard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1455 Test Method for 60-Deg Specular Gloss of Emul-sion Floor Polish3. Significance and Use3.1 This test method is used to
5、determine the effect offreezing on floor polishes. It may be used to predict thestability of a floor polish when exposed to freezing.4. Apparatus4.1 Freezer, adjusted to 7.8 to 6.7C (18 to 20F).4.2 Flint Glass Bottles, three, 4 oz (125 mL) capacity.34.3 Black Glass,4standard, polished as described i
6、n TestMethod D 1455.4.4 60 Gloss Meter.4.5 Polishes to be tested.5. Procedure5.1 Determine the turbidity of each polish, visually or byany other suitable method.5.2 Pour one coat of each polish to be tested on the blackglass. Allow to dry in a vertical position at room temperature.Determine the init
7、ial gloss in accordance with Test MethodD 1455.5.3 Place 100 mL of polish in each of three 125-mL (4-oz)flint glass bottles. Place the filled bottles side by side, horizon-tally, in the freezer on a rack, providing a minimum of 25 mm(1 in.) between the bottles and the freezer walls with thecontact a
8、rea between the bottles and the rack no greater thanthat required to support the bottles.5.4 Allow the samples to remain in the freezer for 16 h, ora minimum of 8 h after becoming solid.5.5 Remove all the samples of frozen polish and allow tothaw, undisturbed, at 18 to 24C (65 to 76F) for a period o
9、f 24h.5.6 Inspect all thawed samples visually. Observe and recordany separation, stratification, or coagulation.5.7 Determine the turbidity on the open sample of polish asin 5.1.5.8 Agitate one bottle of thawed polish and apply one coatof polish to the standard black glass as in 5.2. Determine gloss
10、as in 5.2.5.9 Return the remaining two bottles of polish to the freezerfor 16 h, and repeat 5.4-5.8 for the second freeze/thaw cycle.5.10 Return the third bottle of polish to the freezer for 16 hand again repeat 5.4-5.8.6. Interpretation of Results6.1 The polish passes each freeze/thaw cycle if ther
11、e hasbeen no apparent change in appearance and no significant lossin gloss or increase in turbidity.7. Report7.1 Report test results as the number of cycles passedtogether with visual inspection comments regarding possibleseparation, stratification, or coagulation.1This test method is under the juri
12、sdiction of ASTM Committee D21 on Polishesand is the direct responsibility of Subcommittee D21.03 on Chemical and PhysicalTesting.Current edition approved Sept. 1, 2004. Published September 2004. Originallyapproved in 1973. Last previous edition approved in 1998 as D 3209 93 (1998).2For referenced A
13、STM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Fisher Scientific, Catalog No. 02-883 BA.4Available from Peril
14、 Stein Glass, 2543 Kensington Ave., Phila. PA 19125.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8. Precision and Bias8.1 The test method differentiates polishes that are freezestable from those which are not. Polishes that are bo
15、rderline infreeze/thaw stability may pass in some laboratories and fail inothers.8.2 BiasSince there is no accepted reference materialsuitable for determining the bias for the procedure in TestMethod D 3209 for measuring freeze/thaw resistance of poly-mer emulsion floor polishes, bias has not been d
16、etermined.9. Keywords9.1 emulsion; polishes; polymerASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rig
17、hts, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for
18、 revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing
19、 you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).D 3209 93 (2004)2