1、Designation: D3430 95 (Reapproved 2016)Standard Test Method forClarity and Yellowness of Liquid Water-Based Clear FloorPolishes1This standard is issued under the fixed designation D3430; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers measurement of the degree ofclarity and depth of yellowness of water-based cle
3、ar floorpolishes.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to us
4、e.2. Terminology2.1 Definitions:2.1.1 absorbancethe negative logarithm, to the base 10, ofthe ratio of the radiant power transmitted through a sample tothe radiant power incident upon the sample. Hence, as theclarity decreases or the depth of the yellowness increases theabsorbance increases.3. Signi
5、ficance and Use3.1 The laboratory technique described in this test method isused to evaluate the clarity and yellowness of water-based“clear” floor polishes for product development or qualitycontrol purposes.4. Apparatus4.1 Colorimeter,2equipped with cylindrical 20-mmmatched cells. (If 20-mm cells a
6、re not available, 10-mmmatched cells may be substituted.)4.2 Any colorimeter having equivalent resolution and sen-sitivity may be used with the appropriate matched cells.5. Sampling5.1 The sample shall be representative of the material to betested and the portion used for the test shall be represent
7、ativeof the sample itself.5.2 Calibration SampleAny emulsion polymer that visu-ally exhibits little or no yellowness, selected for dilution (see6.1).6. Preparation of Correction Graph6.1 Prepare minimum of five dilutions of the calibrationsample with distilled water so that absorbance reading betwee
8、n0.00 and 0.16 at 500 nm are obtained. Measure the absorbanceat both 500 nm and 400 nm for each dilution (see Section 7).6.2 Plot the absorbance at 500 nm versus that at 400 nm andfit a straight line through the resulting points starting from theorigin (see Fig. 1).6.3 It is necessary to prepare a c
9、orrection graph only oncefor a given instrument and set of cells.7. Procedure7.1 Adjustment of ColorimeterSet the colorimeter at 500nm and at 0 absorbance with distilled water as a blank in oneof the matched cells.7.2 AbsorbanceFill the companion cell with sample andplace in the cell holder. Read an
10、d record the absorbance. Thisreading is indicative of the degree of turbidity.7.3 Adjustment of ColorimeterReset the colorimeter at400 nm and at 0 absorbance with distilled water as a blank inone of the matched cells.7.4 AbsorbanceRead and record the absorbance of thesample. This reading is indicati
11、ve of the uncorrected yellow-ness.7.5 CorrectionThe corrected value for yellowness is therecorded absorbance from 7.2 corrected to 400 nm from thecorrection graph. Subtract this value from the total absorbanceat 400 nm, 7.4. The difference is the absorbance due toyellowness.8. Report8.1 Report the a
12、bsorbance, indicating the cell size, to thenearest 0.01 unit based on duplicate determinations.1This test method is under the jurisdiction ofASTM Committee D21 on Polishesand is the direct responsibility of Subcommittee D21.03 on Chemical and PhysicalTesting.Current edition approved Oct. 1, 2016. Pu
13、blished October 2016. Originallyapproved in 1975. Last previous edition approved in 2008 as D3430 95 (2008).DOI: 10.1520/D3430-95R16.2Spectronic 70 has been found satisfactory. The sole source of supply of theapparatus known to the committee at this time is Milton-Roy, 820 Linden Ave.,Rochester, NY.
14、 If you are aware of alternative suppliers, please provide thisinformation to ASTM International Headquarters. Your comments will receivecareful consideration at a meeting of the responsible technical committee,1whichyou may attend.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, We
15、st Conshohocken, PA 19428-2959. United States19. Precision and Bias9.1 PrecisionDuplicate determinations obtained on thesame colorimeter that agree within 60.02 units are acceptablefor averaging. Results are comparable only when the same typecolorimeter and the same size cells are used.9.2 BiasThis
16、test method has no bias because the resultsdeveloped are defined only in terms of this test method.10. Keywords10.1 floor polishes; polishesASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this
17、standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years
18、 andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committe
19、e, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-
20、2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 1Three polymers gave identical results.FIG. 1 Correction GraphD3430 95 (2016)2