1、Designation: D3513 02 (Reapproved 2018)Standard Test Method forOverlength Fiber Content of Manufactured Staple Fiber1This standard is issued under the fixed designation D3513; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the percentby number of overlength or multiple length fibers in a sa
3、mpleof manufactured cut staple. The method is applicable to fibertaken immediately after manufacturing, from the bale, or frompartially processed stock.NOTE 1For measurement of length and length distribution of manu-factured staple fibers, refer to Test Method D5103.1.2 This test method covers proce
4、dures using the Fibrosam-pler Model 335A (inch-pound units), the Fibrosampler Model335B (SI units), and Fibrosampler combs Model 336.1.2.1 The Fibrosampler Model 335A is equipped with asample plate that has 15.8-mm (58-in.) diameter sample holesand is recommended for use on blended staple taken from
5、 thefiber blender or from a carding machine.1.2.2 The Fibrosampler Model 335B is equipped with asample plate that has 10-mm (0.4-in.) diameter sample holesand is recommended for use on unblended staple as may betaken from the fiber cutter or from a bale of staple fiber.1.3 The values stated in eithe
6、r SI units or inch-pound unitsare to be regarded separately as the standard. The values statedin each unit are not exact equivalents; therefore, each unit mustbe used independently of the other.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
7、It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles o
8、n standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD1
9、447 Test Method for Length and Length Uniformity ofCotton Fibers by Photoelectric MeasurementD2258 Practice for Sampling Yarn for TestingD3333 Practice for Sampling Manufactured Staple Fibers,Sliver, or Tow for TestingD3888 Terminology for Yarn Spinning SystemsD3990 Terminology Relating to Fabric De
10、fectsD4849 Terminology Related to Yarns and FibersD5103 Test Method for Length and Length Distribution ofManufactured Staple Fibers (Single-Fiber Test)3. Terminology3.1 Definitions:3.1.1 For definitions of textile terms used in this testmethod: fiber beard, staple, overlength staple fibers andmultip
11、le-length staple fibers, refer to Terminology D4849.3.1.2 For definitions of other textile terms used in this testmethod, refer to Terminologies D123, D3888, D3990, andD4849.4. Summary of Test Method4.1 Fibers are caught randomly on a comb to form a fiberbeard. The probability that a given fiber len
12、gth group repre-sented in the original fiber population will appear in the testspecimen is proportional to the ratio of the total length of thatfiber length group to the total fiber length of the originalsample. The beard is biased in the favor of long fibers.4.2 The fiber beard is brushed out and l
13、aid on a specimenboard. The density of the beard of the cut staple tapers to a linethat is parallel to the base of the comb. The overlength fibersare observed to extend beyond this line and they can beidentified easily.4.3 The noticeably longer fibers are pulled from the fiberbeard, verified for ove
14、r- or multiple-length and counted. The1This test method is under the jurisdiction of ASTM Committee D13 on Textilesand is the direct responsibility of Subcommittee D13.58 on Yarns and Fibers.Current edition approved July 1, 2018. Published August 2018. Originallyapproved in 1976. Last previous editi
15、on approved in 2007 as D3513 02(2012).DOI: 10.1520/D3513-02R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM websit
16、e.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of Int
17、ernational Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1result is then expressed as the percent overlength and percentmultiple-length fiber in the original population.5. Significance and Use5.1 The existence of overlength f
18、iber in manufactured staplecan cause serious problems in the spinning of these fibers intoyarn. Overlength fibers may create problems in carding, butmore especially high-strength multiple cut fibers may causecockling in spinning.5.2 Since the overlength fibers are caused by dull ordamaged cutting kn
19、ives or by uneven flow of tow to the staplecutter, their existence within the fiber population is not uniformand their occurrence in the population follows a highly skeweddistribution.5.3 Manual methods of determining overlength fiber requiremuch more operator time, and the standard deviations of th
20、etest between laboratories and operators are high. Use of theFibrosampler method greatly reduces both operator time andstandard deviation of testing.5.4 In manufacturing it is important to know if fibers areoverlength due to looping of the tow or multiple length due todamaged cutters.5.5 This method
21、 for testing staple fiber for overlength fiberis not recommended for acceptance testing (see 13.1).5.5.1 In some cases the purchaser and the supplier may haveto test a commercial shipment of one or more specific materialsby the best available method, even though the method has notbeen recommended fo
22、r acceptance testing of commercialshipments. If there are differences of practical significancebetween reported test results for two laboratories (or more),comparative test should be performed to determine if there is astatistical bias between them, using competent statistical assis-tance. As a mini
23、mum, use the samples for such a comparativetests that are as homogeneous as possible, drawn from the samelot of material as the samples that resulted in disparate resultsduring initial testing and randomly assigned in equal numbersto each laboratory. The test results from the laboratoriesinvolved sh
24、ould be compared using a statistical test forunpaired data, a probability level chosen prior to the testingseries. If a bias is found, either its cause must be found andcorrected, or future test results for that material must beadjusted in consideration of the known bias.6. Apparatus6.1 Fibrosampler
25、,3Model 335A of 335B (Fig. 1), equippedwith the following:6.1.1 Combs,3Model 336 (Fig. 2).6.1.2 Spacing Gage.6.1.3 Specimen Board, board covered with short pile orplush surface on one side, for displaying the test specimen.6.1.4 Brush, for brushing the test specimen.6.1.5 Tweezers, for removing the
26、long fibers from thespecimen board for verification.NOTE 2Fibrosampler Model 192, which is used for sampling cotton,(Method D1447) has been used successfully with this method, but theabove listed models and combs yield better results because long fibers areless likely to be pulled from the combs dur
27、ing beard preparation.6.2 Laboratory Carding Machine or Opener/Blender Model3383is needed for use with Fibrosampler Model 335A.6.3 Analytical Balance, capable of weighing the specimento within 0.01 % of its mass.6.4 Scale, graduated to the nearest 1 mm (116-in.).7. Sampling7.1 Lot SamplingAs a lot s
28、ample for acceptance testing,take at random the number of shipping containers directed inthe applicable material specification or other agreement be-tween the purchaser and supplier, such as an agreement to usePractice D3333 or Practice D2258. Consider shipping contain-ers to be the primary sampling
29、 units.NOTE 3An adequate specification or other agreement between thepurchaser or supplier requires taking into account the variability betweenshipping units, between packages, ends or other laboratory sampling unit3The sole source of supply of the apparatus known to the committee at this timeis Spe
30、cial Instruments Laboratory, Inc., 312 W. Vine Ave., P.O. Box 1950,Knoxville, TN. 37901. If you are aware of alternative suppliers, please provide thisinformation to ASTM International Headquarters. Your comments will receivecareful consideration at a meeting of the responsible technical committee,1
31、whichyou may attend.FIG. 1 FibrosamplerFIG. 2 Fibrosampler CombsD3513 02 (2018)2within a shipping unit if applicable, and within specimens from a singlepackage, end or other laboratory sampling unit to provide a sampling planwith a meaningful producers risk, consumers risk, acceptable qualitylevel,
32、and limiting quantity level.7.2 Laboratory SampleAs a laboratory sample for accep-tance testing, take at random from each shipping container inthe lot sample the number of laboratory sampling units asdirected in an applicable material specification or other agree-ment between purchaser and supplier
33、such as an agreement touse Practice D3333 or Practice D2258. Preferably, the samenumber of laboratory sampling units are taken from eachshipping container in the lot sample. If differing numbers oflaboratory sampling units are to be taken from shippingcontainers in the lot sample, determine at rando
34、m whichshipping containers are to have each number of laboratory unitsdrawn.7.2.1 Take 100-g samples of staple fiber, sliver or top foreach laboratory sampling unit.7.3 Test SpecimensFrom each laboratory sampling unit,take one specimen. If the standard deviation determined for thelaboratory sample i
35、s more than a value agreed upon betweenthe purchaser and supplier, continue testing one specimen fromeach unit in the laboratory sample until the standard deviationfor all specimens tested is not more than the agreed to value or,by agreement, stop testing after a specified number.8. Preparation of T
36、est Specimens8.1 Clean the card clothing on the Fibrosampler before orafter the preparation of each beard to maintain effectivecombing action. To do this, raise the release button (F, Fig. 1)to allow the doffer roller to fall into the cleaning position.Rotate the pivot arm clockwise while holding th
37、e doffer againstthe card clothing. At the bottom of the pivot arm a cleanercomb may be rotated into the doffer clothing by the left handwhile the doffer roll is rotated clockwise by the right hand.8.2 Remove a 25 6 5-g test specimen from each laboratorysample.8.3 Prepare a fiber beard specimen from
38、each test specimenas directed in 8.4 using Fibrosampler Model 335A, or in 8.5using Fibrosampler Model 335B.8.4 Fibrosampler Model 335A:8.4.1 Process the test specimen through a laboratory blendersuch as a laboratory carding machine, or a Model 338Opener/Blender.8.4.2 Place an empty comb in the comb
39、holder.8.4.3 With the left hand, place the test specimen in thecylinder and press it against the curved perforated sampleplate.8.4.4 With a 10 to 20-mm diameter circular motion of theleft hand work the fibers until they protrude through the holesof the sample plate. Then relax the hand pressure agai
40、nst theplate to prevent fiber damage or breakage.8.4.5 With the right hand, turn the pivot arm one completecounterclockwise revolution. This carries the comb teethacross the face of the protruding test sample and allows a fiberbeard to be drawn from the test specimen.NOTE 4Excessive hand pressure on
41、 the test specimen during this stepwill require excessive force to turn the pivot arm and will not allow thefibers to be drawn onto the comb properly and cause excessive fiberdamage during comb loading.8.4.6 Withdraw the comb from its holder.8.5 Fibrosampler 335B:8.5.1 Place an empty comb in the com
42、b holder.8.5.2 With the left hand, place the test specimen in thecylinder and press a small segment of the specimen across andagainst the lower area of the perforated sample plate.8.5.3 With a 10 to 20-mm diameter circular motion of theleft hand, work the fibers until they protrude through the holes
43、of the sample plate. Then relax the hand pressure against theplate to prevent fiber damage or breakage.8.5.4 With the right hand, turn the pivot arm one completecounterclockwise revolution. This carries the comb teethacross the face of the protruding test sample and allows asegment of the fiber bear
44、d to form on the comb. See Note 4.8.5.5 Ease the test specimen from the plate. Rotate the testspecimen to present a new surface and move it up the sampleplate.8.5.6 Continue as directed in 8.5.3 through 8.5.4 until thecomb is uniformly loaded with a milligram mass of 160 to 190times the nominal stap
45、le length.NOTE 5The comb can usually be loaded in three to five turns aroundthe cylinder.8.5.7 Withdraw the comb from its holder.9. Preparation and Adjustment of Apparatus9.1 Set up and adjust the Fibrosampler as directed in themanufacturers instruction manual.9.1.1 Check the clearance between comb
46、and samplingholes in the sampler drum, using the supplied gage. Adjust asnecessary.9.1.2 Test the Fibrosampler comb clamp mechanism forfiber beard holding capability. This may be accomplished bywithdrawing the dog (c, Fig. 2) to open the clamp manually,placing a small tuft of fiber under the teeth o
47、f the comb, closingthe clamp mechanism by forcing the dog into the comb, andthen pulling the fibers. The clamp holding capacity should behigh enough to allow the comb to be picked up by a tuft of 50to 100 fibers.10. Procedure10.1 Place the comb, with the fiber beard firmly clamped, onthe specimen bo
48、ard. Brush the beard to lay flat against theboard surface. The density of the beard will be observed totaper and end at a line representing the nominal cut length ofthe staple.10.2 Measure the distance (to the nearest 1 mm) from thebase of the comb to the line, representing the nominal cutstaple, ob
49、served in 10.1. Overlength fibers will be observed toextend beyond this well-defined line.10.3 Establish a line, located to the nearest 1 mm andparallel to the face of the comb, that is 1.1 times the distancemeasured in 10.2.10.4 Unclamp the fibers by withdrawing the dog (E, Fig. 2).With tweezers, remove those fibers that extend beyond the lineD3513 02 (2018)3established in 10.3. Determine, by measurement to the nearest1 mm (1/16 in.), whether the fibers are actually overlength, ormultiple length, or extending across the line because fiber endsare entangled in a nep,