1、Designation: D4164 13Standard Test Method forMechanically Tapped Packing Density of Formed Catalystand Catalyst Carriers1This standard is issued under the fixed designation D4164; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the me-chanically tapped density of formed catalyst and catalyst
3、carriers. For the purpose of this test method, catalyst particlesare defined as extrudates, spheres, or formed pellets of 0.8 to4.8-mm (132 to316-in.) nominal diameter.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of
4、 the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D3766 Terminology Relating to Catalysts and CatalysisE177 Practice for Use of the Terms Precision and Bi
5、as inASTM Test MethodsE456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE1272 Specification for Laboratory Glass Graduated Cylin-ders3. Terminology3.1 DefinitionsSee Terminology D3766.4. Summary of Test
6、Method4.1 A preconditioned sample of formed catalyst or catalystcarrier is tapped in a graduated cylinder. The mechanicallytapped packing density is determined from the known mass andtapped volume.5. Significance and Use5.1 This test method is to be used for measuring themechanically tapped packing
7、density of formed particles thatwill not break up during sampling, filling, or tapping of themeasuring cylinder under test conditions.6. Apparatus6.1 Graduated Cylinder, capacity 250 mL, conforming toSpecification E1272, Class A, with a base designed to accom-modate the cylinder holder.6.2 Cylinder
8、Holder, weighing approximately 1 lb (454 g).6.3 Tapping Device, consisting of a base-plate with wormdrive, reduction ratio 15:1, nominal cam shaft speed of 250r/min, tapping stroke travel18 in. (3.2 mm).6.4 Four Digit Adjustable Counter, which can be preset todeliver any number of taps between 1 and
9、 9999.6.5 Desiccator, with a desiccant grade molecular sieve suchas No. 4A.6.6 Balance having a sensitivity of 0.1 g.6.7 Drying Oven.7. Procedure7.1 Heat an adequate sample(s) at 400 6 15C for not lessthan 3 h. Normally, this treatment can take place in air.However, in the case of materials that mig
10、ht react with air atelevated temperatures (such as prereduced catalysts) the heattreatment should take place in an inert atmosphere. Afterheating, cool the test sample(s) in a desiccator or other suitablecontainer to eliminate the possibility of moisture adsorptionprior to testing.NOTE 1These condit
11、ions may not be appropriate for all materials.NOTE 2Since many catalyst formulations are strong adsorbents, theuse of No. 4A indicating (cobalt-treated) molecular sieves as a desiccatingmedium is suggested. The desiccant should be regenerated at 493 K(220C) to 533 K (260C), as required.7.2 Pour betw
12、een 240 and 250 mL of the test specimencarefully into the tared graduated cylinder using a funnel. Toensure proper level, rotate the funnel while pouring the testspecimen. Weigh immediately to the nearest 0.1 g.7.3 Preset the counter to 1000 taps.1This test method is under the jurisdiction of ASTM C
13、ommittee D32 onCatalysts and is the direct responsibility of Subcommittee D32.02 on Physical-Mechanical Properties.Current edition approved Dec. 1, 2013. Published December 2013. Originallyapproved in 1988. Last previous edition approved in 2008 as D4164 03 (2008).DOI: 10.1520/D4164-13.2For referenc
14、ed ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
15、shohocken, PA 19428-2959. United States17.4 Start the tapping device.7.5 When tapping is completed, read the tapped volume, V,to the nearest 1 mL by estimating the average level of thecatalyst or catalyst carrier surface in the cylinder.8. Calculation8.1 Calculate mechanically tapped packing density
16、 MTD asfollows:MTD 5 W/V (1)where:W = mass of catalyst particles, g, andV = volume occupied by particles in measuring cylinder,mL.9. Precision and Bias39.1 Test ProgramAn interlaboratory study was conductedin which the named property was measured in two separate testmaterials in three separate labor
17、atories. Practice E691, modi-fied for non-uniform data sets, was followed for the datareduction.9.2 PrecisionPairs of test results obtained by a proceduresimilar to that described in the study are expected to differ inabsolute value by less than 2.772 S, where 2.772 S is the 95 %probability interval
18、 limit on the difference between two testresults, and S is the appropriate estimate of standard deviation.Definitions and usage are given in Terminology E456 andPractice E177, respectively.Test Result 95 % Repeatability Interval 95 % Reproducibility Interval(consensus mean), (within laboratory), (be
19、tween laboratories),kg/L kg/L (% of mean) kg/L (% of mean)0.63911.53330.007 (1.02)0.005 (0.47)0.023 (3.54)0.055 (4.73)9.3 BiasThe procedure in this test method has no biasbecause the value of mechanically tapped packing density canbe defined only in terms of a test method.10. Keywords10.1 carriers;
20、catalyst; mechanically tapped; packing den-sityASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights,
21、and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revi
22、sion of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you
23、shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be o
24、btained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).3Supporting data have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR:D32-1017.D4164 132